アブカムでは最適な動作のために Google Chrome など最新ブラウザでの閲覧を推奨します。

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
お問い合わせは電話 +81-(0)3-6231-0940 または メールでどうぞ

  • アカウント
  • ログアウト
ログイン または 新規登録

Welcome

ログイン または

すでにアカウントをお持ちですか?

新規登録
カート
クイック・オーダー
Abcam homepage

  • 研究用製品
    製品タイプ別
    一次抗体
    二次抗体
    イムノアッセイキット・試薬
    細胞・組織イメージング
    細胞・バイオケミカルアッセイ
    タンパク質・ペプチド
    製品タイプ別
    プロテオミクス
    アゴニスト・アクチベータ-・アンタゴニスト・インヒビター
    細胞株・ライゼート
    miRNA マルチプレックス・アッセイキット
    マルチプレックス・アッセイ
    研究分野別
    癌
    循環器系
    細胞生物学
    エピジェネティクス
    メタボリズム
    発生生物学
    研究分野別
    免疫学
    微生物学
    脳神経科学
    シグナル伝達
    ステムセル
  • カスタム製品 & パートナーシップ
    カスタム製品 & パートナーシップ

    診断や治療プログラムを加速するための、カスタム製品および商業化に向けたパートナーシップ

    カスタム製品

    私たちとパートナーになる

  • サポート
    サポートハブ

    研究のためのサポートとアドバイス

    サポートハブを表示

    プロトコール

    実験のステップごとの詳細

    プロトコールを表示

  • イベント
    • イベント・カレンダー
    • 癌
    • 循環器
    • エピジェネティクス&核内情報
    • 免疫学
    • ニューロサイエンス
    • ステムセル
    • 展示会
    • ウェビナー
    最新のイベント情報

    世界中でアブカムが主催する研究会やセミナーの日程、内容、演者など

    イベント・カレンダー

  • パスウェイ
    細胞シグナル伝達パスウェイ

    すべてのパスウェイを見る

    インタラクティブ・パスウェイを見る

  1. Link

    testosterone-elisa-kit-ab108666.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Signal Transduction Signaling Pathway Nuclear Signaling Nuclear Hormone Receptors Testosterone
Share by email

Testosterone ELISA Kit (ab108666)

  • Datasheet
  • SDS
  • Protocol Booklet
Reviews (5)Q&A (10)References (44)

Product price, shipping and contact information

Currently unavailable

申し訳ございませんが、現在表示できません。

こちらにお問い合わせいただくか、またはしばらく経ってから改めてお試しください

 

Loading size & price…

 

出荷および受注について

Shipping info

Promotion Information

Abpromise

保証された製品品質、優れたカスタマー・サポート。 詳細はこちら。

Biological fluids for ab108666
  • Typical Standard Curve

Key features and details

  • Sensitivity: 0.07 ng/ml
  • Range: 0.2 ng/ml - 16 ng/ml
  • Sample type: Cit plasma, Hep Plasma, Serum, Urine
  • Detection method: Colorimetric
  • Assay type: Competitive
  • Reacts with: Human

こちらの製品もご検討ください

ELISA
Product image
Human Progesterone ELISA Kit (ab108670)
アッセイ
Product image
Lysyl Oxidase Activity Assay Kit (Fluorometric) (ab112139)
ELISA
Product image
Human MMP1 ELISA Kit (ab215083)

関連製品

製品の概要

  • 製品名

    Testosterone ELISA Kit
    Testosterone キット 製品一覧
  • 検出方法

    Colorimetric
  • 再現性

    Intra-Assay(同時再現性)
    サンプル N 平均値 SD CV%
    Control Sera 48 <=5.8%
    Inter-Assay(日差再現性)
    サンプル N 平均値 SD CV%
    Control Sera 48 <=10.5%
  • サンプルの種類

    Urine, Serum, Hep Plasma, Cit plasma
  • アッセイタイプ

    Competitive
  • 検出感度

    = 0.07 ng/ml
  • 検出範囲

    0.2 ng/ml - 16 ng/ml
  • 添加回収試験

    = 105.5 %

  • ステップ

    Multiple steps standard assay
  • 種交差性

    交差種: Human
  • 製品の概要

    Testosterone ELISA kit is a competitive ELISA designed for the accurate quantitative measurement of Testosterone in serum and plasma.


    A 96-well plate has been precoated with anti-Testosterone antibodies. Samples and the Testosterone-HRP conjugate are added to the wells, where Testosterone in the sample competes with the added Testosterone-HRP for antibody binding. After incubation, the wells are washed to remove unbound material and TMB substrate is then added which is catalyzed by HRP to produce blue coloration. The reaction is terminated by addition of Stop Solution which stops the color development and produces a color change from blue to yellow. The intensity of signal is inversely proportional to the amount of Testosterone in the sample and the intensity is measured at 450 nm.

  • 試験プラットフォーム

    Microplate

製品の特性

  • 保存方法

    Store at +4°C. Please refer to protocols.
  • 内容 1 x 96 tests
    10X Wash Buffer 1 x 50ml
    Cover foils 1 unit
    Stop Solution 1 x 15ml
    Strip holder 1 unit
    Testosterone conjugate 1 x 12ml
    Testosterone Control A 1 x 1ml
    Testosterone Control B 1 x 1ml
    Testosterone IgG Coated Microtiter Plate (12 x 8 wells) 1 unit
    Testosterone Standard 0 - 0.0 ng/mL 1 x 1ml
    Testosterone Standard 1 - 0.2 ng/mL 1 x 1ml
    Testosterone Standard 2 - 1.0 ng/mL 1 x 1ml
    Testosterone Standard 3 - 4.0 ng/mL 1 x 1ml
    Testosterone Standard 4 - 16.0 ng/mL 1 x 1ml
    TMB Substrate Solution 1 x 15ml
  • 研究分野

    • Signal Transduction
    • Signaling Pathway
    • Nuclear Signaling
    • Nuclear Hormone Receptors
    • Testosterone
    • Signal Transduction
    • Growth Factors/Hormones
    • Hormones
    • Epigenetics and Nuclear Signaling
    • Nuclear Signaling Pathways
    • Nuclear Receptors
    • Testosterone
    • Developmental Biology
    • Reproduction
    • Hormones
    • Kits/ Lysates/ Other
    • Kits
    • ELISA Kits
    • ELISA Kits
    • Growth factors and hormones ELISA kits
  • 別名

    • 17ß-hydroxyandrost-4-ene-3-one
  • 参照データベース

    • SwissProt: P04278 Human

    画像

    • Biological fluids for ab108666
      Biological fluids for ab108666

      Testosterone measured in biological fluids showing quantity (ng) per mL of tested sample. Samples were diluted 1-2 fold.

    • Typical Standard Curve
      Typical Standard Curve

      Representative Standard Curve using ab108666

    プロトコール

    • Protocol Booklet

    Click here to view the general protocols

    データシートおよび資料

    • SDS download

    • Datasheet download

      Download

    参考文献 (44)

    ab108666 を使用した論文を発表された方は、こちらまでお知らせください。データシートに掲載させていただきます。

    ab108666 は 44 報の論文で使用されています。

    • Chen J  et al. Decreased blood vessel density and endothelial cell subset dynamics during ageing of the endocrine system. EMBO J 40:e105242 (2021). PubMed: 33215738
    • Venditti M  et al. Preliminary Investigation on the Ameliorative Role Exerted by D-Aspartic Acid in Counteracting Ethane Dimethane Sulfonate (EDS) Toxicity in the Rat Testis. Animals (Basel) 11:N/A (2021). PubMed: 33435542
    • Van Simaeys G  et al. [18F]-JK-PSMA-7 and [18F]-FDG tumour PET uptake in treated xenograft human prostate cancer model in mice. Eur J Nucl Med Mol Imaging 48:1773-1784 (2021). PubMed: 33398412
    • Mohammed S  et al. Effect of 150?kHz electromagnetic radiation on the development of polycystic ovaries induced by estradiol Valerate in Sprague Dawley rats. J Ovarian Res 14:26 (2021). PubMed: 33546719
    • Soliman MM  et al. Impacts of n-acetyl cysteine on gibberellic acid-induced testicular dysfunction through regulation of inflammatory cytokines, steroid and antioxidant activity. Andrologia 53:e14036 (2021). PubMed: 33724537
    View all Publications for this product

    レビューと Q&A

    Show All レビュー Q&A
    レビューを送る 質問を送る

    1-10 of 15 Abreviews or Q&A

    Replacement for ab174569

    Good Excellent 5/5 (Ease of Use)
    Abreviews
    Abreviews
    abreview image
    Ordered as replacement for discontinued ab174569 for use on EDTA plasma (was informed ab108666 not yet validated for EDTA). Blood was collected in EDTA tubes (BD) and plasma separated by ficoll gradient was then span 2000g 10mins before aliquoting to freeze -80C. Samples were later thawed and assayed immediately, without dilution. ab108666 coped fine with samples >2ng/ml when measured by ab174569, although quantifying lower than ab174569, but samples <2ng/ml were all below LOD (set to 0.1ng/ml).
    The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

    Abcam user community

    Verified customer

    投稿 Jul 11 2022

    Dr Frances Orton

    Excellent Excellent 5/5 (Ease of Use)
    Abreviews
    Abreviews
    abreview image
    I used this product for common frog (Rana temporaria) urine. I first checked the levels of testosterone in the urine by measuring dilutions of 2 test samples against the highest and lowest concentrations of the standards. From this I was able to determine that the urine should be applied to the ELISA neat and did not require any dilution.
    Levels of testosterone in the 88 samples that I tested were low, and in some cases below the lowest testosterone standard (see photograph).
    The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

    Frances Orton

    Verified customer

    投稿 Sep 04 2020

    Easy to use but maybe not suitable for mouse serum

    Below average Excellent 5/5 (Ease of Use)
    Abreviews
    Abreviews
    We tried to use this kit to measure testosterone in mouse serum but were unable to measure anything in serum from normal WT mice. I suspect matrix effect interfered with measurements in neat or 1:2 diluted samples and more dilute samples (1 to 10) might have had levels below the detection limit. It is possible that further optimization or testing of other dilutions may help.
    The standard worked really well and the product was easy to use. I would consider this kit if I ever have to measure testosterone in human samples but not for mouse.
    The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

    Abcam user community

    Verified customer

    投稿 Oct 23 2018

    Works in guinea pig plasma

    Excellent Excellent 5/5 (Ease of Use)
    Abreviews
    Abreviews
    abreview image
    Bought this kit to try with guinea pig plasma. Kit was easy to use, fast and instructions were clear. From my results, it seems to have worked well in the guinea pig. Male samples all fell within the curve at expected concentrations.
    The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

    Abcam user community

    Verified customer

    投稿 May 26 2017

    Question

    Does this kit ab108666 cross react with mouse testosterone as well?

    Read More

    Abcam community

    Verified customer

    Asked on Mar 19 2014

    Answer

    Testosterone is a biochemical and it should be same in all the species so theoretically this kit would work with testosterone from all the species. We however have tested it with human samples only. Please note the amount of testosterone is higher in urine as compared to serum and plasma samples.

    Read More

    Padamjeet Singh

    Abcam Scientific Support

    Answered on Mar 19 2014

    Question

    I would like to know what solution to use to dilute samples since in the kit there is none.

    Read More

    Abcam community

    Verified customer

    Asked on Dec 08 2016

    Answer

    Samples can be diluted in PBS.

    Read More

    Abcam Scientific Support

    Answered on Dec 08 2016

    Question

    I have a couple of questions regarding this kit. First, is there a way to ascertain free testosterone from this kit as well, or is it necessary to perform a separate ELISA? Second, how many wells on the plate are used for controls?

    Read More

    Abcam community

    Verified customer

    Asked on Oct 26 2016

    Answer

    This assay will measure total testosterone, free and also protein-bound. To measure just free testosterone, we have another assay, https://www.abcam.com/human-testosterone-free-elisa-kit-ab178663.html.


    We recommend running the two controls in duplicate, so those will require 4 wells. The five standards in duplicate will require 10 wells. One more well is needed for the substrate blank.

    Read More

    Abcam Scientific Support

    Answered on Oct 26 2016

    Question

    Which buffer can be used for diluting serum samples?

    Read More

    Abcam community

    Verified customer

    Asked on Oct 10 2016

    Answer

    I can confirm the lab used PBS to dilute serum samples when validating the kit.

    Read More

    Abcam Scientific Support

    Answered on Oct 10 2016

    Question

    I am using undiluted serum and plasma samples and observing high OD values. Do you have any suggestion why is this so?

    Read More

    Abcam community

    Verified customer

    Asked on Sep 01 2016

    Answer

    This is most likely due to matrix effect which affect measurement of analyte of interest in ELISA when undiluted serum or plasma samples are used. Matrix effect can arise from a number of matrix components such as phospholipids, carbohydrates, and endogenous metabolites (bilirubin), residual formulation components from intraperitoneal (ip), intravenous (iv), or oral dosing (po) experiments; for example, polyethylene glycol (PEG), solutol, polysorbate (Tween 80), etc, an interaction between the analyte of interest and the matrix, such as covalent binding to plasma proteins or the enzymatic degradation of a prodrug.  The easiest way to overcome this is by using diluted samples e.g. 1/2 or 1/10 dilution.

    Read More

    Abcam Scientific Support

    Answered on Sep 01 2016

    Question

    Does the assay detect both protein bound and free testosterone? Or is all testosterone considered bound to protein?

    Read More

    Abcam community

    Verified customer

    Asked on Aug 26 2014

    Answer

    The test measures both bound and free Testosterone.

    Read More

    Sybille Rex

    Abcam Scientific Support

    Answered on Aug 26 2014

    1-10 of 15 Abreviews or Q&A

    •  戻る
    • 1
    • 2
    • 次へ 

    Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
    For licensing inquiries, please contact partnerships@abcam.com

    技術情報や製品情報をメールで受け取る 登録
    製品・研究分野別
    • 癌
    • 循環器
    • 細胞生物学
    • 発生
    • エピジェネティクス&核内情報
    • 免疫学
    • メタボリズム
    • 感染症
    • ニューロサイエンス
    • シグナル伝達
    • ステムセル
    製品・タイプ別
    • 一次抗体
    • 二次抗体
    • バイオケミカルズ
    • アイソタイプ・コントロール
    • マルチカラー・セレクター
    • キット
    • ローディング・コントロール
    • ライゼート
    • ペプチド
    • タンパク質
    • スライド
    • タグ抗体・細胞マーカー
    • その他試薬
    サービス&サポート
    • サポート
    • よくあるお問い合わせ
    • プロトコール&トラブルシュート
    • ご購入に関して
    • お問い合わせフォーム
    • トレーニング
    • ターゲット別に見る
    アブカムについて
    • 企業ウェブサイト
    • 投資家の皆様へ
    • 企業情報
    • 採用情報
    • アブカムについて
    イベント
    • 展示会
    • カンファレンス
    International websites
    • abcam.com
    • abcam.cn

    Join with us

    • LinkedIn
    • facebook
    • Twitter
    • YouTube
    • Terms of sale
    • Website terms of use
    • Cookie policy
    • Privacy policy
    • Legal
    © 1998-2022 Abcam plc. All rights reserved.