Abcam's TMB ELISA Substrate (Slower Kinetic Rate) detects horseradish peroxidase (HRP) activity and contains 3,3',5,5'-tetramethylbenzidine in a mildly acidic buffer.
1 Images
ELISA - TMB ELISA Substrate (Slower Kinetic Rate) (AB171526)
  • ELISA

Unknown

ELISA - TMB ELISA Substrate (Slower Kinetic Rate) (AB171526)

Comparison of the kinetic curves of several TMB substrates at 500 pg/mL msIgG monitored over time at 650 nm.

Key facts

アプリケーション

ELISA

applications

製品の状態

Liquid

form

バッファー組成

pH: 1 - 5 Constituents: 79% Water, 0.1% Hydrogen peroxide, 0.05% 3,3',5,5'-Tetramethylbenzidine

storage-buffer

Reactivity data

{ "title": "Reactivity Data", "filters": { "stats": ["", "Reactivity", "Dilution Info", "Notes"] }, "values": { "ELISA": { "reactivity":"TESTED_AND_REACTS", "dilution-info":"1/1", "notes":"<p>100 µL of substrate solution is added to each well.</p>" }, "IHC-P": { "reactivity":"TESTED_AND_DOES_NOT_REACT", "dilution-info":"", "notes":"<p></p>" }, "IHC-Fr": { "reactivity":"TESTED_AND_DOES_NOT_REACT", "dilution-info":"", "notes":"<p></p>" } } }

製品の詳細

Abcam's TMB ELISA Substrate (Slower Kinetic Rate) detects horseradish peroxidase (HRP) activity and contains 3,3',5,5'-tetramethylbenzidine in a mildly acidic buffer. The substrate is supplied as a ready to use solution. Unreacted substrate should be colorless or very light yellow in appearance. When this substrate system is reacted with peroxidase, a soluble blue reaction product is obtained. The reaction can be stopped using appropriate stop solution, producing a soluble yellow or soluble blue reaction product, depending upon the stop reagent used, which is stable for at least 1 hour. ab171526 is not recommended for membrane or immunohistochemical applications that require a precipitating reaction product.

Product Use:
ab171526 is supplied as a ready to use solution. The product should be allowed to equilibrate to room temperature (25°C) prior to use. For microwell applications, 100 μL of substrate solution is added to each well. A soluble blue reaction product develops which can be read at 370 nm or in a range of 620 nm to 650 nm. For best results, sample absorbance values should be monitored and read before absorbance values exceed 2.0 OD units. In endpoint assays, the substrate reaction can be stopped using equal volumes of 1 N HCl, 0.6 N sulfuric acid, or one of the stop solutions (ab171529 and ab171531). Addition of acid turns the blue color to yellow and stops the enzymatic reaction. In the case of the 650 nm Stop Solutions for TMB Substrate (ab171531), the blue color does not change. Since stopping the reaction increases sample absorbance values approximately three fold, unless using the 650 nm Stop Solutions for TMB Substrate (ab171531), sample OD values should be monitored and substrate reaction stopped when values reach approximately 0.7 OD units. After stopping with the 450 nm Stop Solutions for TMB Substrate (ab171529), a soluble yellow product develops which is read in the 450 nm range. Stopping with the 650 nm Stop Solutions for TMB Substrate (ab171531) produces a soluble blue product which is read in the 650 nm range. Dilution of the substrate is not recommended. To reduce the intensity of a reaction, it is recommended that the antibodies or conjugates be diluted.

Storage Instructions:

Exposure to direct sunlight and other UV sources should be avoided due to the light sensitive nature of the TMB molecule.

出荷温度及び保存条件

出荷温度
Ambient - Can Ship with Ice
短期保存期間
1-2 weeks
短期保存温度
+4°C
長期保存温度
+4°C
保管に関する情報
Store in the dark

製品プロトコール

ターゲットの情報

Abcam product promise

当社は、高品質な試薬を通じてお客様の研究を力強くサポートすることをお約束いたします。ご使用いただく各段階で、常にお客様をサポートできる体制を整えております。万が一、製品が期待通りに機能しない場合は、「Abcam Product Promise」による当社保証制度に基づき、安心してご利用いただけます。
保証に関する詳細については利用規約をご確認ください。

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com