Anti-Robo4 抗体 [EPR26282-3] (ab300046)
Key features and details
- Produced recombinantly (animal-free) for high batch-to-batch consistency and long term security of supply
- Rabbit monoclonal [EPR26282-3] to Robo4
- Suitable for: IHC-P, WB
- Reacts with: Mouse, Rat, Human
Related conjugates and formulations
製品の概要
-
製品名
Anti-Robo4 antibody [EPR26282-3]
Robo4 一次抗体 製品一覧 -
製品の詳細
Rabbit monoclonal [EPR26282-3] to Robo4 -
由来種
Rabbit -
アプリケーション
適用あり: IHC-P, WBmore details
適用なし: Flow Cyt (Intra),ICC/IF,IHC-Fr or IP -
種交差性
交差種: Mouse, Rat, Human -
免疫原
Synthetic peptide. This information is proprietary to Abcam and/or its suppliers.
-
ポジティブ・コントロール
- WB: HUVEC (human umbilical vein endothelial cell); Human heart tissue lysate; Mouse & Rat spleen tissue lysates; Mouse & Rat kidney tissue lysates. IHC-P: Human & Mouse colon; Mouse pancreatic cancer; Rat cerebrum
-
特記事項
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free production
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
製品の特性
-
製品の状態
Liquid -
保存方法
Shipped at 4°C. Store at +4°C short term (1-2 weeks). Upon delivery aliquot. Store at -20°C long term. Avoid freeze / thaw cycle. -
バッファー
pH: 7.20
Preservative: 0.01% Sodium azide
Constituents: 59% PBS, 40% Glycerol (glycerin, glycerine), 0.05% BSA -
Concentration information loading...
-
精製度
Protein A purified -
ポリ/モノ
モノクローナル -
クローン名
EPR26282-3 -
アイソタイプ
IgG -
研究分野
関連製品
-
Alternative Versions
-
Compatible Secondaries
アプリケーション
The Abpromise guarantee
Abpromise保証は、 次のテスト済みアプリケーションにおけるab300046の使用に適用されます
アプリケーションノートには、推奨の開始希釈率がありますが、適切な希釈率につきましてはご検討ください。
アプリケーション | Abreviews | 特記事項 |
---|---|---|
IHC-P |
1/100. Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
|
|
WB |
1/1000. Predicted molecular weight: 107 kDa.
|
特記事項 |
---|
IHC-P
1/100. Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol. |
WB
1/1000. Predicted molecular weight: 107 kDa. |
ターゲット情報
- Information by UniProt
-
参照データベース
- Entrez Gene: 54538 Human
- Entrez Gene: 74144 Mouse
- Entrez Gene: 300518 Rat
- Omim: 607528 Human
- SwissProt: Q8WZ75 Human
- SwissProt: Q8C310 Mouse
- SwissProt: Q80W87 Rat
- Unigene: 524121 Human
see all -
別名
- ECSM4 antibody
- FLJ20798 antibody
- Magic roundabout antibody
see all
画像
-
All lanes : Anti-Robo4 antibody [EPR26282-3] (ab300046) at 1/1000 dilution
Lane 1 : HUVEC (human umbilical vein endothelial cell) whole cell lysate
Lane 2 : HeLa (human cervix adenocarcinoma epithelial cell) whole cell lysate
Lane 3 : HCT 116 (human colorectal carcinoma epithelial cell) whole cell lysate
Lysates/proteins at 20 µg per lane.
Secondary
All lanes : Goat Anti-Rabbit IgG H&L (HRP) (ab97051) at 1/20000 dilution
Predicted band size: 107 kDa
Observed band size: 60 kDa why is the actual band size different from the predicted?
Exposure time: 15 secondsBlocking / Diluting buffer and concentration:
5% NFDM/TBST
-
All lanes : Anti-Robo4 antibody [EPR26282-3] (ab300046) at 1/1000 dilution
Lane 1 : Human heart tissue lysate
Lane 2 : Mouse spleen tissue lysate
Lane 3 : Mouse kidney tissue lysate
Lane 4 : Rat spleen tissue lysate
Lane 5 : Rat kidney tissue lysate
Lysates/proteins at 20 µg per lane.
Secondary
All lanes : Goat Anti-Rabbit IgG, (H+L), Peroxidase conjugated (ab97051);Goat Anti-Rabbit IgG (HRP) with minimal cross-reactivity with human IgG. Secondary ab dilution 1:2000;1:20,000
Predicted band size: 107 kDa
Observed band size: 60 kDa why is the actual band size different from the predicted?
Exposure time: 15 secondsBlocking / Diluting buffer and concentration:5% NFDM/TBST
The molecular weight observed is consistent with what have been described in literature (PMID: 27882935).
Negative controls: HeLa, HCT 116(PMID: 11944987, PMID: 11076864 ). -
Immunohistochemical analysis of paraffin-embedded Human colon tissue labeling Robo4 with abab300046 at 1/100 (3.77 µg/ml) followed by a ready to use LeicaDS9800 (BOND™ Polymer Refine Detection). Positive staining on endothelial cells in human colon. The section was incubated with ab300046 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use LeicaDS9800 (BOND™ Polymer Refine Detection).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
-
Immunohistochemical analysis of paraffin-embedded Mouse colon tissue labeling Robo4 with abab300046 at 1/100 (3.77 µg/ml) followed by a ready to use LeicaDS9800 (BOND™ Polymer Refine Detection). Positive staining on endothelial cells in mouse colon. The section was incubated with ab300046 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use LeicaDS9800 (BOND™ Polymer Refine Detection).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
-
Immunohistochemical analysis of paraffin-embedded Mouse pancreatic can tissue labeling Robo4 with abab300046 at 1/100 (3.77 µg/ml) followed by a ready to use LeicaDS9800 (BOND™ Polymer Refine Detection). Positive staining on endothelial cells in mouse pancreatic cancer. The section was incubated with ab300046 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use LeicaDS9800 (BOND™ Polymer Refine Detection).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
-
Immunohistochemical analysis of paraffin-embedded Rat cerebrum tissue labeling Robo4 with abab300046 at 1/100 (3.77 µg/ml) followed by a ready to use LeicaDS9800 (BOND™ Polymer Refine Detection) was used. Positive staining on endothelial cells in rat cerebrum. The section was incubated with ab300046 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
Secondary antibody only control: Secondary antibody is a ready to use LeicaDS9800 (BOND™ Polymer Refine Detection).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
プロトコール
To our knowledge, customised protocols are not required for this product. Please try the standard protocols listed below and let us know how you get on.
データシートおよび資料
-
SDS download
-
Datasheet download
Certificate of Compliance
参考文献 (0)
ab300046 は論文での使用が確認できていません。