Rabbit Recombinant Monoclonal MCH antibody. Carrier free. Suitable for IHC-P, IHC-Fr and reacts with Human, Mouse, Rat samples.
別名を表示する
MCH, PMCH, Pro-MCH
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-MCH antibody [EPR23778-94] - BSA and Azide free (AB274423)
This data was developed using ab274415, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Human hypothalamus tissue labeling PMCH with ab274415 at 1/2000 (0.271 ug/ml) dilution followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on human hypothalamus (PMID : 30420052). The section was incubated with ab274415 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-MCH antibody [EPR23778-94] - BSA and Azide free (AB274423)
This data was developed using ab274415, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Rat hypothalamus tissue labeling PMCH with ab274415 at 1/2000 (0.271 ug/ml) dilution followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on rat hypothalamus (PMID : 30420052). The section was incubated with ab274415 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
- IHC-Fr
Unknown
Immunohistochemistry (Frozen sections) - Anti-MCH antibody [EPR23778-94] - BSA and Azide free (AB274423)
This data was developed using ab274415, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of 4% PFA-fixed, 0.2% Triton X-100 permeabilized frozen Mouse hypothalamus tissue labeling PMCH with ab274415 at 1/500 (1.084 ug/ml) dilution followed by ab150077 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) at 1/1000 dilution (Green). Positive staining on mouse hypothalamus is observed. The nuclear counterstain was DAPI (Blue).
Secondary antibody control : Secondary antibody is ab150077 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) at 1/1000 dilution.
Heat mediated antigen retrieval using sodium citrate buffer (10mM citrate pH 6.0 + 0.05% Tween-20).
- IHC-Fr
Unknown
Immunohistochemistry (Frozen sections) - Anti-MCH antibody [EPR23778-94] - BSA and Azide free (AB274423)
This data was developed using ab274415, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of 4% PFA-fixed, 0.2% Triton X-100 permeabilized frozen Rat hypothalamus tissue labeling PMCH with ab274415 at 1/500 (1.084 ug/ml) dilution followed by ab150077 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) at 1/1000 dilution (Green). Positive staining on rat hypothalamus is observed. The nuclear counterstain was DAPI (Blue).
Secondary antibody control : Secondary antibody is ab150077 Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) at 1/1000 dilution.
Heat mediated antigen retrieval using sodium citrate buffer (10mM citrate pH 6.0 + 0.05% Tween-20).
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-MCH antibody [EPR23778-94] - BSA and Azide free (AB274423)
This data was developed using ab274415, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded Mouse hypothalamus tissue labeling PMCH with ab274415 at 1/2000 (0.271 ug/ml) dilution followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on mouse hypothalamus (PMID : 30420052). The section was incubated with ab274415 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins.
関連する標識済み抗体及び組成の異なる製品 (1)
-
Anti-MCH antibody [EPR23778-94]
Reactivity data
製品の詳細
ab274423 is the carrier-free version of ab274415.
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
出荷温度及び保存条件
製品の状態
精製方法
バッファー組成
出荷温度
短期保存温度
長期保存温度
保管に関する情報
補足情報
This supplementary information is collated from multiple sources and compiled automatically.
Biological function summary
MCH affects a range of physiological processes and is part of the neuropeptide signaling system. It regulates feeding and energy homeostasis by influencing appetite increase and reducing energy expenditure. MCH operates within a complex network of neurotransmitters and hormones in the central nervous system. Its interactions with other neuropeptides such as neuropeptide Y (NPY) and agouti-related peptide (AgRP) support its role in the complex regulation of energy homeostasis.
Pathways
MCH engages in signaling linked to G-protein coupled receptors (GPCRs) connecting with pathways that regulate food intake and energy management. It influences the orexin/hypocretin pathway which also modulates sleep-wake cycles and arousal states. The interaction with orexin highlights MCH's broad regulatory influence balancing energy levels and adaptive responses. The protein's signaling is associated with molecules like leptin and insulin marking its integration into wider metabolic pathways.
製品プロトコール
- Visit the General protocols
- Visit the Troubleshooting
ターゲットの情報
Abcam product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com