Anti-HRPT2/Parafibromin 抗体 [EPR19927] - BSA and Azide free
Anti-HRPT2/Parafibromin antibody [EPR19927] - BSA and Azide free
- RabMAb
- Recombinant
- 詳細を見る
Be the first to review this product! Submit a review
|
(0 Publication)
Rabbit Recombinant Monoclonal HRPT2/Parafibromin antibody. Carrier free. Suitable for WB, Flow Cyt (Intra), IHC-P and reacts with Human, Mouse, Rat samples.
別名を表示する
C1orf28, HRPT2, CDC73, Parafibromin, Cell division cycle protein 73 homolog, Hyperparathyroidism 2 protein
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-HRPT2/Parafibromin antibody [EPR19927] - BSA and Azide free (AB251575)
This data was developed using ab223840, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded human parathyroid carcinoma case 1 (A) and human parathyroid carcinoma case 2 (B) labeling HRPT2/Parafibromin with ab223840 at 1/1000 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Nuclear staining observed in one parathyroid carcinoma case, while another case was found to be negative for the target (PMID : 16728578). Counter stained with hematoxylin.
Secondary antibody only control : Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) Ready to use.
Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-HRPT2/Parafibromin antibody [EPR19927] - BSA and Azide free (AB251575)
This data was developed using ab223840, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded human kidney (A) and human clear cell renal cell carcinoma (B) labeling HRPT2/Parafibromin with ab223840 at 1/1000 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Nuclear staining of human kidney epithelium; human clear cell renal cell carcinoma is negative for HRPT2/Parafibromin (PMID : 23361235). Counter stained with hematoxylin.
Secondary antibody only control : Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) Ready to use.
Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
- Flow Cyt (Intra)
Unknown
Flow Cytometry (Intracellular) - Anti-HRPT2/Parafibromin antibody [EPR19927] - BSA and Azide free (AB251575)
This data was developed using ab223840, the same antibody clone in a different buffer formulation.
Intracellular flow cytometric analysis of 4% paraformaldehyde fixed, 90% methanol permeabilized HeLa (human epithelial cell line from cervix adenocarcinoma) cell line labeling HRPT2/Parafibromin with ab223840 at 1/500 dilution (red) compared with a Rabbit IgG, monoclonal [EPR25A] - Isotype Control (ab172730) (black) and an unlabeled control (cells without incubation with primary antibody and secondary antibody) (blue). Goat Anti-Rabbit IgG H&L (Alexa Fluor® 488) (ab150077) at 1/2000 dilution was used as the secondary antibody.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-HRPT2/Parafibromin antibody [EPR19927] - BSA and Azide free (AB251575)
This data was developed using ab223840, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded rat brain tissue labeling HRPT2/Parafibromin with ab223840 at 1/1000 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Nuclear staining in neurons in rat brain is observed. Counter stained with hematoxylin.
Secondary antibody only control : Used PBS instead of primary antibody, secondary antibody is followed by Goat Anti-Rabbit IgG H&L (HRP) Ready to use.
Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-HRPT2/Parafibromin antibody [EPR19927] - BSA and Azide free (AB251575)
This data was developed using ab223840, the same antibody clone in a different buffer formulation.
Immunohistochemical analysis of paraffin-embedded mouse brain tissue labeling HRPT2/Parafibromin with ab223840 at 1/1000 dilution, followed by Goat Anti-Rabbit IgG H&L (HRP) Ready to use. Nuclear staining in neurons in murine neurons is observed. Counter stained with hematoxylin.
Secondary antibody only control : Used PBS instead of primary antibody, secondary antibody is Goat Anti-Rabbit IgG H&L (HRP) Ready to use.
Perform heat mediated antigen retrieval with Tris/EDTA buffer pH 9.0 before commencing with IHC staining protocol.
- WB
Supplier Data
Western blot - Anti-HRPT2/Parafibromin antibody [EPR19927] - BSA and Azide free (AB251575)
This data was developed using ab223840, the same antibody clone in a different buffer formulation.
Blocking and dilution buffer : 5% NFDM/TBST.
Exposure times : Lanes 1-3 : 30 seconds; Lane 4 : 3 minutes.
All lanes:
Western blot - Anti-HRPT2/Parafibromin antibody [EPR19927] (<a href='/products/primary-antibodies/hrpt2-parafibromin-antibody-epr19927-ab223840'>ab223840</a>) at 1/1000 dilution
Lane 1:
HeLa (human epithelial cell line from cervix adenocarcinoma) whole cell lysate at 20 µg
Lane 2:
Caco-2 (human colorectal adenocarcinoma cell line) whole cell lysate at 20 µg
Lane 3:
HepG2 (human liver hepatocellular carcinoma cell line) whole cell lysate at 20 µg
Lane 4:
Human fetal kidney lysate at 10 µg
Secondary
Lanes 1 - 3:
Western blot - Goat Anti-Rabbit IgG H&L (HRP) (<a href='/products/secondary-antibodies/goat-rabbit-igg-h-l-hrp-ab97051'>ab97051</a>) at 1/100000 dilution
Lane 4:
Goat Anti-Rabbit IgG Peroxidase Conjugate, specific to the non-reduced form of IgG at 1/10000 dilution
Predicted band size: 61 kDa
Observed band size: 60 kDa
true
関連する標識済み抗体及び組成の異なる製品 (10)
-
Anti-HRPT2/Parafibromin antibody [EPR19927]
-
660 APC
APC Anti-HRPT2 antibody [EPR19927]
-
519 Alexa Fluor® 488
Alexa Fluor® 488 Anti-HRPT2 antibody [EPR19927]
-
565 Alexa Fluor® 555
Alexa Fluor® 555 Anti-HRPT2 antibody [EPR19927]
-
603 Alexa Fluor® 568
Alexa Fluor® 568 Anti-HRPT2/Parafibromin antibody [EPR19927]
-
617 Alexa Fluor® 594
Alexa Fluor® 594 Anti-HRPT2 antibody [EPR19927]
-
665 Alexa Fluor® 647
Alexa Fluor® 647 Anti-HRPT2 antibody [EPR19927]
-
775 Alexa Fluor® 750
Alexa Fluor® 750 Anti-HRPT2/Parafibromin antibody [EPR19927]
-
HRP Anti-HRPT2 antibody [EPR19927]
-
578 PE
PE Anti-HRPT2 antibody [EPR19927]
Reactivity data
製品の詳細
ab251575 is the carrier-free version of ab223840.
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
What are the advantages of a recombinant monoclonal antibody?
This product is a recombinant monoclonal antibody, which offers several advantages including:
- - High batch-to-batch consistency and reproducibility
- - Improved sensitivity and specificity
- - Long-term security of supply
- - Animal-free batch production
For more information, read more on recombinant antibodies.
Conjugation ready
Our carrier-free antibodies are typically supplied in a PBS-only formulation, purified and free of BSA, sodium azide and glycerol. This conjugation-ready format is designed for use with fluorochromes, metal isotopes, oligonucleotides, and enzymes, which makes them ideal for antibody labelling, functional and cell-based assays, flow-based assays (e.g. mass cytometry) and Multiplex Imaging applications.
Use our conjugation kits for antibody conjugates that are ready-to-use in as little as 20 minutes with 1 minute hands-on-time and 100% antibody recovery: available for fluorescent dyes, HRP, biotin and gold.
Compatibility
This product is compatible with the Maxpar® Antibody Labeling Kit from Fluidigm, without the need for antibody preparation. Maxpar® is a trademark of Fluidigm Canada Inc.
出荷温度及び保存条件
製品の状態
精製方法
バッファー組成
出荷温度
短期保存温度
長期保存温度
保管に関する情報
製品プロトコール
- Visit the General protocols
- Visit the Troubleshooting
ターゲットの情報
Abcam product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com