FITC Anti-Legionella pneumophila 抗体 (ab20818)
Key features and details
- FITC Rabbit polyclonal to Legionella pneumophila
- Suitable for: ICC/IF
- Reacts with: Legionella pneumophila
- Conjugation: FITC. Ex: 493nm, Em: 528nm
- Isotype: IgG
製品の概要
-
製品名
FITC Anti-Legionella pneumophila antibody
Legionella pneumophila 一次抗体 製品一覧 -
製品の詳細
FITC Rabbit polyclonal to Legionella pneumophila -
由来種
Rabbit -
標識
FITC. Ex: 493nm, Em: 528nm -
アプリケーション
適用あり: ICC/IFmore details -
種交差性
交差種: Legionella pneumophila -
免疫原
Tissue, cells or virus corresponding to Legionella pneumophila. A whole cell preparation of Legionella pneumophila (ATCC 33152)
-
特記事項
Purified IgG fraction is covalently coupled with high purity Isomer I of fluorescein isothiocyanate. Care is taken to ensure complete removal of any free fluorescein from the final product.
The Life Science industry has been in the grips of a reproducibility crisis for a number of years. Abcam is leading the way in addressing this with our range of recombinant monoclonal antibodies and knockout edited cell lines for gold-standard validation. Please check that this product meets your needs before purchasing.
If you have any questions, special requirements or concerns, please send us an inquiry and/or contact our Support team ahead of purchase. Recommended alternatives for this product can be found below, along with publications, customer reviews and Q&As
製品の特性
-
製品の状態
Liquid -
保存方法
Shipped at 4°C. Store at +4°C. -
バッファー
Preservative: 0.1% Sodium azide
Constituents: 0.0268% PBS, 1% BSA -
Concentration information loading...
-
精製度
IgG fraction -
ポリ/モノ
ポリクローナル -
アイソタイプ
IgG -
研究分野
関連製品
-
Isotype control
アプリケーション
The Abpromise guarantee
Abpromise保証は、 次のテスト済みアプリケーションにおけるab20818の使用に適用されます
アプリケーションノートには、推奨の開始希釈率がありますが、適切な希釈率につきましてはご検討ください。
アプリケーション | Abreviews | 特記事項 |
---|---|---|
ICC/IF |
Use at an assay dependent dilution.
|
特記事項 |
---|
ICC/IF
Use at an assay dependent dilution. |
ターゲット情報
-
関連性
Legionella pneumophila is a flagellated gram negative bacterium found primarily in warm water environments. Legionella pneumophila causes a type of pneumonia called Legionnaire disease and a milder condition called Pontiac fever. Infection is acquired through inhalation of the microorganism in water mists (e.g. from air conditioning, cooling towers, whirlpool spas and showers mists). A number of risk factors for acquiring Legionnaire disease have been identified, including age, smoking, chronic lung disease, cancer, and immunosuppression.
データシートおよび資料
-
SDS download
-
Datasheet download
参考文献 (3)
ab20818 は 3 報の論文で使用されています。
- Nisar MA et al. Detection and quantification of viable but non-culturable Legionella pneumophila from water samples using flow cytometry-cell sorting and quantitative PCR. Front Microbiol 14:1094877 (2023). PubMed: 36793878
- Keserue HA et al. Rapid detection of total and viable Legionella pneumophila in tap water by immunomagnetic separation, double fluorescent staining and flow cytometry. Microb Biotechnol 5:753-63 (2012). PubMed: 23062200
- Füchslin HP et al. Rapid and quantitative detection of Legionella pneumophila applying immunomagnetic separation and flow cytometry. Cytometry A 77:264-74 (2010). PubMed: 20099248