Anti-Cytokeratin 5 抗体 [SP178]
Anti-Cytokeratin 5 antibody [SP178]
- RabMAb
- Recombinant
- 詳細を見る
0
(1 Review)
|
(1 Publication)
Rabbit Recombinant Monoclonal Cytokeratin 5 antibody. Suitable for Flow Cyt (Intra), IHC-P, ICC/IF and reacts with Human samples. Cited in 1 publication.
別名を表示する
58 kDa cytokeratin, Cytokeratin-5, Keratin-5, Type-II keratin Kb5, CK-5, K5, KRT5, CK5
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) analysis of Human tonsil tissue sections labeling Cytokeratin 5 with ab183336 at 1/100 dilution (2.35 µg/ml). Heat mediated antigen retrieval was performed Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 10 mins. Rabbit specific IHC polymer detection kit HRP/DAB (ab209101) was used as the secondary antibody. Negative control : PBS instead of the primary antibody. Hematoxylin was used as a counterstain.
- ICC/IF
Unknown
Immunocytochemistry/ Immunofluorescence - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunocytochemistry/ Immunofluorescence analysis of A431 (human epidermoid carcinoma epithelial cell) cells labeling Cytokeratin 5 with purified ab183336 at 1/50 (4.7 μg/ml). Cells were fixed in 4% paraformaldehyde and permeabilized with 0.1% Triton X-100. Cells were counterstained with ab195889 Anti-alpha Tubulin antibody [DM1A] - Microtubule Marker (Alexa Fluor® 594) 1/200 (2.5 μg/ml). Goat anti rabbit IgG (Alexa Fluor® 488, ab150077) was used as the secondary antibody at 1/1000 (2 μg/ml) dilution. DAPI (blue) was used as nuclear counterstain. PBS instead of the primary antibody was used as the secondary antibody only control.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemical analysis of formalin-fixed, paraffin-embedded Human bladder tissue labeling Cytokeratin 5 with ab183336 at 1/100 dilution.
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemical analysis of formalin-fixed, paraffin-embedded Human tonsil tissue labeling Cytokeratin 5 with ab183336 at 1/100 dilution.
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemical analysis of formalin-fixed, paraffin-embedded Human skin tissue labeling Cytokeratin 5 with ab183336 at 1/100 dilution.
- Flow Cyt (Intra)
Unknown
Flow Cytometry (Intracellular) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Flow Cytometry analysis of A431 (human epidermoid carcinoma epithelial cell) cells labeling Cytokeratin 5 with purified ab183336 at 1/20 dilution (11.75 μg/ml) (red). Cells were fixed with 4% paraformaldehyde and permeabilised with 90% methanol. A Goat anti rabbit IgG (Alexa Fluor® 488, ab150077) secondary antibody was used at 1/2000 dilution. Isotype control - Rabbit monoclonal IgG (ab172730) / Black. Unlabeled control - Unlabelled cells / blue.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemical analysis of formalin-fixed, paraffin-embedded Human rectal carcinoma tissue labeling Cytokeratin 5 with ab183336 at 1/100 dilution.
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemical analysis of formalin-fixed, paraffin-embedded Human breast tissue labeling Cytokeratin 5 with ab183336 at 1/100 dilution.
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) analysis of Human cervix carcinoma tissue sections labeling Cytokeratin 5 with ab183336 at 1/100 dilution (2.35 µg/ml). Heat mediated antigen retrieval was performed Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 10 mins. Rabbit specific IHC polymer detection kit HRP/DAB (ab209101) was used as the secondary antibody. Negative control : PBS instead of the primary antibody. Hematoxylin was used as a counterstain.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemical analysis of formalin-fixed, paraffin-embedded Human lung squamous cell carcinoma tissue labeling Cytokeratin 5 with ab183336 at 1/100 dilution.
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) analysis of Human prostate tissue sections labeling Cytokeratin 5 with ab183336 at 1/100 dilution (2.35 µg/ml). Heat mediated antigen retrieval was performed Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution 2) for 10 mins. Rabbit specific IHC polymer detection kit HRP/DAB (ab209101) was used as the secondary antibody. Negative control : PBS instead of the primary antibody. Hematoxylin was used as a counterstain.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemical analysis of formalin-fixed, paraffin-embedded Human prostate tissue labeling Cytokeratin 5 with ab183336 at 1/100 dilution.
- IHC-P
Unknown
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemical analysis of formalin-fixed, paraffin-embedded Human skin squamous cell carcinoma tissue labeling Cytokeratin 5 with ab183336 at 1/100 dilution.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Immunohistochemical analysis of formalin-fixed, paraffin-embedded Human cervix squamous cell carcinoma tissue labeling Cytokeratin 5 with ab183336 at 1/100 dilution.
- Flow Cyt (Intra)
Supplier Data
Flow Cytometry (Intracellular) - Anti-Cytokeratin 5 antibody [SP178] (AB183336)
Flow cytometric analysis of A431 cells labeling Cytokeratin 5 with ab183336 at 1/100 dilution (green) compared to a negative control rabbit IgG (blue).
関連する標識済み抗体及び組成の異なる製品 (1)
-
Anti-Cytokeratin 5 antibody [SP178] - BSA and Azide free
Reactivity data
製品の詳細
There are no definitive signs to indicate instability of this product; therefore, positive and negative controls should be tested simultaneously with unknown specimens.
Patented technology
Our RabMAb® technology is a patented hybridoma-based technology for making rabbit monoclonal antibodies. For details on our patents, please refer to RabMAb® patents.
出荷温度及び保存条件
製品の状態
精製方法
精製に関する特記事項
バッファー組成
出荷温度
短期保存期間
短期保存温度
長期保存温度
分注に関する情報
保管に関する情報
製品プロトコール
- Visit the General protocols
- Visit the Troubleshooting
ターゲットの情報
文献 (1)
Recent publications for all applications. Explore the full list and refine your search
PloS one 10:e0125255 PubMed25955027
2015
Applications
Unspecified application
Species
Unspecified reactive species
Abcam product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com