JavaScript is disabled in your browser. Please enable JavaScript to view this website.
AB243298

Tissue Clearing Kit - hydrophobic

Tissue Clearing Kit - hydrophobic

5

(1 Review)

|

(3 Publications)

Tissue Clearing Kit ab243298 enables the easy set-up of rapid tissue clearing for 3D tissue imaging using simple protocols and standard laboratory equipment.
2 Images
Immunohistochemistry (PFA fixed) - Tissue Clearing Kit - hydrophobic (AB243298)
  • IHC (PFA fixed)

Supplier Data

Immunohistochemistry (PFA fixed) - Tissue Clearing Kit - hydrophobic (AB243298)

GFAP antibody ab7260 was used with Tissue Clearing Kit ab243298 to penetrate, stain and clear a 1 mm coronal section of mouse brain.

Immunohistochemistry (PFA fixed) - Tissue Clearing Kit - hydrophobic (AB243298)
  • IHC (PFA fixed)

Supplier Data

Immunohistochemistry (PFA fixed) - Tissue Clearing Kit - hydrophobic (AB243298)

NeuN antibody ab177487 was used with Tissue Clearing Kit ab243298 to penetrate, stain and clear a 1 mm coronal section of mouse brain.

Key facts

Reactivity data

{ "title": "Reactivity Data", "filters": { "stats": ["", "Reactivity", "Dilution Info", "Notes"] }, "values": { "Histology": { "reactivity":"TESTED_AND_REACTS", "dilution-info":"", "notes":"<p></p>" } } }

製品の詳細

Tissue Clearing Kit - hydrophobic ab243298 enables the easy set-up of rapid tissue clearing for 3D tissue imaging using simple protocols and standard laboratory equipment.

The kit enables you to set up tissue clearing easily and clear tissue quickly. The protocols are simple and use standard laboratory equipment, and can be used with immunostaining, fluorescent proteins and chemical dyes. Clearing is reversible so that you can treat your sample for conventional H&E or IHC staining after 3D imaging.

To help you get started with tissue clearing, we have tissue clearing validated antibodies. Validated antibodies are for key markers, such as NeuN, GFAP, Iba1, etc, and are tested for tissue clearing with 1 mm mouse brain sections, and also for 3D cell culture clearing with neuronal spheroids and hepatic spheroids (depending on the marker).

If you want to set up tissue clearing on a sample type that we haven’t tested or to use your own antibodies, please consult the protocol book for this kit.

To learn more about tissue clearing, and tissue clearing methods (including for 3D cell cultures), please review our guide to tissue clearing.

Tissue clearing reagents and companion products are also available as individual products.

These tissue clearing reagents were developed with Visikol Inc, who developed the Visikol® HISTO™ tissue clearing technology which is the basis of our reagents.

Simplified tissue clearing and immunostaining workflow:

- fix tissue section in your preferred fixative
- dehydrate with increasing % methanol series
- incubate with DMSO/methanol
- rehydrate with decreasing % methanol series
- incubate with Penetration Buffer
- block with Blocking Buffer
- stain with primary antibody, wash, stain with secondary antibody
- dehydrate with increasing % methanol series
- incubate with Tissue Clearing Reagent 1
- incubate with Tissue Clearing Reagent 2
- image tissue section

The full process, excluding fixation time and imaging, can be completed in ~ 3 days.

The workflow shown is for immuno-staining a 1 mm brain section, see kit protocol book for guidance for fluorescent proteins, labeling with chemical dyes, and other sample types / thicknesses.

Suitable sample types:

The tissue clearing reagents can be used with mammalian tissues of thicknesses ranging from conventional thin tissue sections up to whole organs.

When starting to use tissue clearing, we recommend using sections of no more than 1 mm thick; at this thickness, protocols are shorter, there are less requirements on the equipment used for imaging, and the volume of data generated is less, so analysis is easier.

We recommend consulting the kit protocol book before collecting tissue samples.

If you are preparing 1 or 2 mm mouse brain sections, we recommend our Brain Slicers.

Imaging:

Please consult the section on Imaging in the kit protocol book, before purchasing the kit. Confocal microscopes and light sheet microscopes are often suitable for 3D imaging of cleared tissues.

If you are using an air gap objective, you should also purchase a Silicon Imaging Chamber.

If you are using an immersion objective, you may require a double chambered cuvette.

製品内容

{ "values": { "30mL": { "sellingSize": "30 mL", "publicAssetCode":"ab243298-30mL", "assetComponentDetails": [ { "size":"1 x 30 mL", "name":"Tissue Clearing Penetration Buffer", "number":"AB243298-CMP03" }, { "size":"1 x 70 mL", "name":"Tissue Clearing Washing Buffer 10X", "number":"AB243298-CMP07" }, { "size":"1 x 30 mL", "name":"Tissue Clearing Blocking Buffer", "number":"AB243298-CMP02" }, { "size":"1 x 30 mL", "name":"Tissue Clearing Antibody Buffer", "number":"AB243298-CMP01" }, { "size":"1 x 30 mL", "name":"Tissue Clearing Permeabilization Buffer", "number":"AB243298-CMP04" }, { "size":"1 x 30 mL", "name":"Tissue Clearing Reagent 1", "number":"AB243298-CMP05" }, { "size":"1 x 30 mL", "name":"Tissue Clearing Reagent 2", "number":"AB243298-CMP06" } ] }, "15mL": { "sellingSize": "15 mL", "publicAssetCode":"ab243298-15mL", "assetComponentDetails": [ { "size":"1 x 15 mL", "name":"Tissue Clearing Reagent 1", "number":"AB243298-CMP05", "productcode":"" }, { "size":"1 x 35 mL", "name":"Tissue Clearing Washing Buffer 10X", "number":"AB243298-CMP07", "productcode":"" }, { "size":"1 x 15 mL", "name":"Tissue Clearing Permeabilization Buffer", "number":"AB243298-CMP04", "productcode":"" }, { "size":"1 x 15 mL", "name":"Tissue Clearing Penetration Buffer", "number":"AB243298-CMP03", "productcode":"" }, { "size":"1 x 15 mL", "name":"Tissue Clearing Reagent 2", "number":"AB243298-CMP06", "productcode":"" }, { "size":"1 x 15 mL", "name":"Tissue Clearing Blocking Buffer", "number":"AB243298-CMP02", "productcode":"" }, { "size":"1 x 15 mL", "name":"Tissue Clearing Antibody Buffer", "number":"AB243298-CMP01", "productcode":"" } ] } } }

出荷温度及び保存条件

出荷温度
Blue Ice
短期保存温度
Multi
長期保存温度
Multi
保管に関する情報
Please refer to protocols

製品プロトコール

ターゲットの情報

文献 (3)

Recent publications for all applications. Explore the full list and refine your search

Science translational medicine 14:eabn4819 PubMed35857641

2022

Miswiring of Merkel cell and pruriceptive C fiber drives the itch-scratch cycle.

Applications

Unspecified application

Species

Unspecified reactive species

Jing Feng,Yonghui Zhao,Zili Xie,Kaikai Zang,Sanja Sviben,Xueming Hu,James A J Fitzpatrick,Lu Wen,Yifei Liu,Ting Wang,Katy Lawson,Qin Liu,Yan Yan,Xinzhong Dong,Liang Han,Gregory F Wu,Brian S Kim,Hongzhen Hu

Viruses 13: PubMed34452455

2021

Bioprinted Multi-Cell Type Lung Model for the Study of Viral Inhibitors.

Applications

Unspecified application

Species

Unspecified reactive species

Johanna Berg,Zia Weber,Mona Fechler-Bitteti,Andreas C Hocke,Stefan Hippenstiel,Laura Elomaa,Marie Weinhart,Jens Kurreck

Cancer discovery 10:1566-1589 PubMed32703770

2020

Intraductal Transplantation Models of Human Pancreatic Ductal Adenocarcinoma Reveal Progressive Transition of Molecular Subtypes.

Applications

Unspecified application

Species

Unspecified reactive species

Koji Miyabayashi,Lindsey A Baker,Astrid Deschênes,Benno Traub,Giuseppina Caligiuri,Dennis Plenker,Brinda Alagesan,Pascal Belleau,Siran Li,Jude Kendall,Gun Ho Jang,Risa Karakida Kawaguchi,Tim D D Somerville,Hervé Tiriac,Chang-Il Hwang,Richard A Burkhart,Nicholas J Roberts,Laura D Wood,Ralph H Hruban,Jesse Gillis,Alexander Krasnitz,Christopher R Vakoc,Michael Wigler,Faiyaz Notta,Steven Gallinger,Youngkyu Park,David A Tuveson
View all publications
websiteProtocolBooklet
en

Abcam product promise

当社は、高品質な試薬を通じてお客様の研究を力強くサポートすることをお約束いたします。ご使用いただく各段階で、常にお客様をサポートできる体制を整えております。万が一、製品が期待通りに機能しない場合は、「Abcam Product Promise」による当社保証制度に基づき、安心してご利用いただけます。
保証に関する詳細については利用規約をご確認ください。

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com