Rabbit specific IHC polymer detection kit HRP/DAB
Rabbit specific IHC polymer detection kit HRP/DAB
Be the first to review this product! Submit a review
|
(27 Publications)
- Signal amplification is achieved using an indirect polymer detection system and does not use avidin or biotin.
- Proven performance: cited in over 25 publications
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human cervical squamous carcinoma tissue labeling ING4 with ab323509 at 1/50 (10.26 ug/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining in human cervical squamous carcinoma.
The section was incubated with ab323509 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed using ab93684 (Tris/EDTA buffer, pH 9.0)
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human testis tissue labeling TM6SF2 with ab325553 at 1/200 (2.47 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Low expression tissue : no staining on human testis (PMID : 24531328). The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Panel A. Human colon tissue labeling BCKDHA (phospho S293) with ab302504 at 1/500 (0.948 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Mitochondrial staining on human colon without alkaline phosphatase treatment (Panel A). No signal was detected when tissues were treated with alkaline phosphatase (Panel B). The section was incubated with ab302504 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Wild-type HeLa (Human cervical adenocarcinoma epithelial cell) cell pellet (A) and RRM2B KO HeLa cell pellet (B) labelling p53R2 with ab154194 at 1 : 2500 (0.044 μg/ml). Positive staining on (A) wild-type HeLa cell pellet, no staining on (B) RRM2B KO HeLa A431 cell pellet. The primary antibody was incubated for 30 mins at room temperature. Secondary antibody was a Ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human cardiac muscle tissue labeling Sarcomeric Alpha Actinin with ab68168 at 1/2000 dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human cardiac muscle.
The primary antibody was incubated for 30 mins at room temperature.
Counterstained with Hematoxylin.
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human ileum tissue labeling TM6SF2 with ab325553 at 1/200 (2.47 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human ileum. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Panel A. Human colon tissue labeling BCKDHA (phospho S293) with ab302504 at 1/500 (0.948 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Mitochondrial staining on human colon cancer without alkaline phosphatase treatment (Panel A). No signal was detected when tissues were treated with alkaline phosphatase (Panel B) (PMID : 32238881). The section was incubated with ab302504 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded human tonsil tissue labelling S100A8 with ab92331 at 1/5000 dilution, followed by Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on human tonsil is observed. Counter stained with Hematoxylin.
Secondary antibody only control : Used PBS instead of primary antibody, secondary antibody is Rabbit specific IHC polymer detection kit HRP/DAB ab209101.
Positive staining on human tonsil.
The section was incubated with ab92331 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human tonsil tissue lABeling Flotillin 2/ESA with ab307422 at 1/1000 (0.535 ug/ml) followed by a ready to use RABbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on human tonsil. The section was incubated with ab307422 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is a ready to use RABbit specific IHC polymer detection kit HRP/DAB (ab209101). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human testis tissue labeling CDCA2 with ab325345 at 1/100 (5.16 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human testis. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND®RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human ovarian cancer tissue labeling CDCA2 with ab325345 at 1/100 (5.16 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human ovarian cancer. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human liver tissue labeling TM6SF2 with ab325553 at 1/200 (2.47 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human liver. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded (A) SK-OV-3 (human ovarian cancer epithelial cell) cell pellet (B) HEK-293T (human embryonic kidney epithelial cell) cell pellet tissue labeling TM6SF2 with ab325553 at 1/200 (2.47 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on SK-OV-3 (image A), no staining on HEK293T (image B). The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Paraffin embedded human brain tissue slides were dewaxed, followed by heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, Epitope Retrieval ER2 Solution) for 20 mins. Endogenous peroxidase activity was blocked with 3% H2O2 for 10 mins. The sections were then incubated with ab254349 (1/1000) at room temperature for 30 mins, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The sections were counterstained with Hematoxylin. The images were taken with a Leica Aperio AT2.
ab254349 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in IHC-P. The image shows the staining intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected under these conditions. This data was generated as part of a structured antibody stability study supporting Abcam’s transition from cold‑chain to ambient shipping.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Panel A. Wild-type H tissue labeling BCKDHA (phospho S293) with ab302504 at 1/500 (0.948 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Mitochondrial staining on HEK-293T without alkaline phosphatase treatment (Panel A). No signal was detected when cells were treated with alkaline phosphatase (Panel B). No staining on BCKDHA KO HEK-293T cell pellets (Panel C). The section was incubated with ab302504 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND® RX instrument Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, epitope retrieval solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human thymus tissue labeling with ab326426 at 1/100 (5.01 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human thymus.
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human cerebrum tissue labeling ATP13A2 with ab322735 at 1/100 (5.24 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human cerebrum. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human hepatocellular tissue labeling Flotillin 2/ESA with ab307422 at 1/1000 (0.535 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on human hepatocellular carcinoma (PMID : 28560058). The section was incubated with ab307422 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND RX instrument Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded human skin tissue labeling Filaggrin with ab221155 at 1/1000 dilution followed by a Ready to use Rabbit specific IHC polymer detection kit (ab209101).
Positive staining on human skin.
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Paraffin embedded human skeletal muscle tissue slides were dewaxed, followed by heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, Epitope Retrieval ER2 Solution) for 20 mins. Endogenous peroxidase activity was blocked with 3% H2O2 for 10 mins. The sections were then incubated with ab68167 (1/300) at room temperature for 30 mins, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The sections were counterstained with Hematoxylin. The images were taken with a Leica Aperio AT2.
ab68167 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in IHC-P. The image shows the staining intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected
This blot was produced using 4-20% SDS-PAGE containing 15 μg of mouse brain lysate per lane at 150V for 1hr before being transferred onto a 0.45 μm PVDF membrane at 75V for 1hr. The membrane was then blocked for 1hr using 5% NFDM/TBST, then incubated with ab68167 (1/20,000) at room temperature for 1hr. After being washed three times in TBST, the membrane was incubated with Peroxidase conjugated goat anti-rabbit IgG (H+L) (ab97051) at 1/100,000 dilution for 1hr at room temperature. The membrane was washed three times again. Then the signal was developed using the ECL technique.
ab68167 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in WB. The image shows the band intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected under these conditions. This data was generated as part of a structured antibody stability study supporting Abcam’s transition from cold‑chain to ambient shipping.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded human colon carcinoma tissue labeling FAK with ab40794 at 1/500 dilution.
Positive staining on human colon carcinoma tissue.
The section was incubated with ab40794 for 30 mins at room temperature.
Rabbit specific IHC polymer detection kit HRP/DAB (ab209101) was used as the secondary antibody system (ready-to-use).
The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
Counterstained with Hematoxylin.
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Paraffin embedded human kidney tissue slides were dewaxed, followed by heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, Epitope Retrieval ER2 Solution) for 20 mins. Endogenous peroxidase activity was blocked with 3% H2O2 for 10 mins. The sections were then incubated with ab124715 (1/400) at room temperature for 30 mins, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The sections were counterstained with Hematoxylin. The images were taken with a Leica Aperio AT2.
ab124715 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in IHC-P. The image shows the staining intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected
The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Paraffin embedded human kidney tissue slides were dewaxed, followed by heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, Epitope Retrieval ER2 Solution) for 20 mins. Endogenous peroxidase activity was blocked with 3% H2O2 for 10 mins. The sections were then incubated with ab124715 (1/400) at room temperature for 30 mins, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The sections were counterstained with Hematoxylin. The images were taken with a Leica Aperio AT2.
ab124715 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in IHC-P. The image shows the staining intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected under these conditions. This data was generated as part of a structured antibody stability study supporting Abcam’s transition from cold‑chain to ambient shipping.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human lymph node tissue labeling CDCA2 with ab325345 at 1/100 (5.16 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human lymph node. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Paraffin embedded human tonsil tissue slides were dewaxed, followed by heat mediated antigen retrieval with Citrate buffer (pH 6.0, Epitope Retrieval ER1 Solution) for 10 mins. Endogenous peroxidase activity was blocked with 3% H2O2 for 10 mins. The sections were then incubated with ab183322 (1/100) at room temperature for 30 mins, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The sections were counterstained with Hematoxylin. The images were taken with a Leica Aperio AT2.
ab183322 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in IHC-P. The image shows the staining intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected
This blot was produced using 4-20% SDS-PAGE containing 15 μg of human tonsil lysate per lane at 150V for 1hr before being transferred onto a 0.45 μm PVDF membrane at 75V for 1hr. The membrane was then blocked for 1hr using 5% NFDM/TBST, then incubated with ab183322 (1/1000) at room temperature for 1hr. After being washed three times in TBST, the membrane was incubated with Peroxidase conjugated goat anti-rabbit IgG with minimal cross-reactivity with human IgG at 1/2000 dilution for 1hr at room temperature. The membrane was washed three times again. Then the signal was developed using the ECL technique.
ab183322 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in WB. The image shows the band intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected under these conditions. This data was generated as part of a structured antibody stability study supporting Abcam’s transition from cold‑chain to ambient shipping.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded (A) 786-O (human kidney epithelial cell) cell pellet (B) HDLM-2 (human Hodgkin lymphoma cell) cell pellet (C) HeLa (human cervical adenocarcinoma epithelial cell) cell pellet (D) Raji (human Burkitt's lymphoma B lymphocyte) cell pellet tissue labeling with ab326426 at 1/500 (1.002 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on (A) 786-O and (B) HDLM-2 cell pellets; no staining on (C) HeLa and (D) HT-29 cell pellets.
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Paraffin embedded human tonsil tissue slides were dewaxed, followed by heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, Epitope Retrieval ER2 Solution) for 20 mins. Endogenous peroxidase activity was blocked with 3% H2O2 for 10 mins. The sections were then incubated with ab231036 (1/3000) at room temperature for 30 mins, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The sections were counterstained with Hematoxylin. The images were taken with a Leica Aperio AT2.
ab231036 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in IHC-P. The image shows the staining intensity remains relatively constant for temperatures ranging between 4°C, 22°C and 37°C, demonstrating that antibody activity is not affected under these conditions. This data was generated as part of a structured antibody stability study supporting Abcam’s transition from cold‑chain to ambient shipping.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human cerebrum tissue labeling JIP3 with ab326560 at 1/500 (1.024 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive on human cerebrum. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human testis tissue labeling JIP3 with ab326560 at 1/500 (1.024 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive on human testis. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human spleen tissue labeling JIP3 with ab326560 at 1/500 (1.024 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Low expression : Weak staining on human spleen. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Paraffin embedded human stomach tissue slides were dewaxed, followed by heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, Epitope Retrieval ER2 Solution) for 20 mins. Endogenous peroxidase activity was blocked with 3% H2O2 for 10 mins. The sections were then incubated with ab124744 (1/50) at room temperature for 30 mins, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The sections were counterstained with Hematoxylin. The images were taken with a Leica Aperio AT2.
ab124744 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in IHC-P. The image shows the staining intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected under these conditions. This data was generated as part of a structured antibody stability study supporting Abcam’s transition from cold‑chain to ambient shipping.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human liver carcinoma tissue labeling TM6SF2 with ab325553 at 1/200 (2.47 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human liver carcinoma. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Paraffin embedded human endometrium tissue slides were dewaxed, followed by heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, Epitope Retrieval ER2 Solution) for 20 mins. Endogenous peroxidase activity was blocked with 3% H2O2 for 10 mins. The sections were then incubated with ab124764 (1/500) at room temperature for 30 mins, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The sections were counterstained with Hematoxylin. The images were taken with a Leica Aperio AT2.
ab124767 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in IHC-P. The image shows the staining intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human tonsillitis tissue labeling with ab326426 at 1/100 (5.01 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human tonsillitis.
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded (A) Wildtype HEK-293 (human embryonic kidney epithelial cell) cell pellet and (B) ATP13A2 knockout HEK-293 cell pellet. tissue labeling ATP13A2 with ab322735 at 1/100 (5.24 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on (A) Wildtype HEK-293 cell pellet, no staining on (B) ATP13A2 knockout HEK-293 cell pellet. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human Parkinson's disease brain tissue labeling ATP13A2 with ab322735 at 1/100 (5.24 µg/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human Parkinson's disease brain. The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument
Counterstained with Hematoxylin.
Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded human brain tissue labeling PAK3 with ab40808 at 1/50 dilution (3.98 μg/ml).
Positive staining on human brain.
The section was incubated with ab40808 for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
Counterstained with Hematoxylin.
Heat mediated antigen retrieval using Bond™ Epitope Retrieval Solution 2 (pH 9.0) for 20 mins.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Paraffin embedded human stomach tissue slides were dewaxed, followed by heat mediated antigen retrieval with Tris-EDTA buffer (pH 9.0, Epitope Retrieval ER2 Solution) for 20 mins. Endogenous peroxidase activity was blocked with 3% H2O2 for 10 mins. The sections were then incubated with ab32575 (1/2000) at room temperature for 30 mins, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). The sections were counterstained with Hematoxylin. The images were taken with a Leica Aperio AT2.
ab32575 was stored at a range of temperatures (+4°C, +22°C, +37°C) for 1 week before being tested in IHC-P. The image shows the staining intensity remains relatively constant across all storage temperatures, demonstrating that antibody activity is not affected under these conditions. This data was generated as part of a structured antibody stability study supporting Abcam’s transition from cold‑chain to ambient shipping.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded Human breast carcino tissue labeling Flotillin 2/ESA with ab307422 at 1/1000 (0.535 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on human breast carcinoma (PMID : 22869152). The section was incubated with ab307422 for 30 mins at room temperature. The immunostaining was performed on a Leica Biosystems BOND RX instrument Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IHC-P
Supplier Data
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded (A) Wild-type HEK293 tissue labeling Flotillin 2/ESA with ab307422 at 1/1000 (0.535 ug/ml) followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Positive staining on (A) wild-type HEK293T cell pellet, no staining on (B) FLOT2 knockout HEK293T cell pellet. The section was incubated with ab307422 for 30 mins at room temperature.The immunostaining was performed on a Leica Biosystems BOND RX instrument Counterstained with Hematoxylin. Secondary antibody only control : Secondary antibody is a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101). Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded human kidney tissue labeling PDGFR alpha with ab203491 A, B. at 1/100 dilution (5.81μg/ml) overnight at 4 °C, and C, at 1/2000 dilution (0.29 μg/ml) for 30 mins at room temperature. A, Goat Anti-Rabbit IgG H&L (HRP polymer) (ab214880) used as secondary (ready to use), B, C. Rabbit specific IHC polymer detection kit HRP/DAB (ab209101) used as secondary (ready to use). Counterstained using Hematoxylin. The immunostaining was performed on a Leica Biosystems BOND® RX instrument. Positive staining on human kidney. A, B : Heat mediated antigen retrieval using ab93684 (Tris/EDTA buffer, pH 9.0). C : Heat mediated antigen retrieval using Bond™ Epitope Retrieval Solution 2 (pH 9.0) for 20 mins.
This antibody is better suited for Leica Biosystems BOND® RX instrument. For manual detection, please use the Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
- IHC-P
Lab
Immunohistochemistry (Formalin/PFA-fixed paraffin-embedded sections) - Rabbit specific IHC polymer detection kit HRP/DAB (AB209101)
Immunohistochemical analysis of paraffin-embedded human colon tissue labeling Methionine Aminopeptidase 2/p67 with ab134124 at 1/1000 (0.986 ug/ml) dilution, followed by a ready to use Rabbit specific IHC polymer detection kit HRP/DAB (ab209101).
Positive staining on human colon.
The primary antibody was incubated for 30 mins at room temperature.
The immunostaining was performed on a Leica Biosystems BOND® RX instrument.
Heat mediated antigen retrieval was performed with Tris-EDTA buffer (pH 9.0, Epitope Retrieval Solution2) for 20 mins.
Reactivity data
製品の詳細
As Rabbit specific IHC polymer detection kit HRP/DAB does not use avidin or biotin, nonspecific staining from endogenous avidin-biotin activity is eliminated and there is no need for additional steps to block endogenous biotin.
How the kit works
- Primary antibody specific to an antigen on the tissue section is detected by primary antibody Amplifier.
- HRP polymer is added to enable detection with signal amplification.
- Antibody-bound antigen sites are visualized by adding an appropriate substrate/chromogen (not provided). We recommend the DAB Substrate Kit (ab64238).
Find complete IHC kits, and reagents for antigen retrieval, blocking, signal amplification, visualization, counterstaining, and mounting in the IHC kits and reagents guide.
製品内容
出荷温度及び保存条件
出荷温度
短期保存温度
長期保存温度
保管に関する情報
ターゲットの情報
文献 (27)
Recent publications for all applications. Explore the full list and refine your search
Molecular medicine (Cambridge, Mass.) 31:141 PubMed40251491
2025
Applications
Unspecified application
Species
Unspecified reactive species
Molecular medicine reports 30: PubMed39329201
2024
Applications
Unspecified application
Species
Unspecified reactive species
Journal of nanobiotechnology 22:100 PubMed38462597
2024
Applications
Unspecified application
Species
Unspecified reactive species
Frontiers in oral health 5:1337582 PubMed38370876
2024
Applications
Unspecified application
Species
Unspecified reactive species
Journal of nanobiotechnology 21:431 PubMed37978538
2023
Applications
Unspecified application
Species
Unspecified reactive species
Cells 12: PubMed37947632
2023
Applications
Unspecified application
Species
Unspecified reactive species
International journal of general medicine 15:7383-7393 PubMed36164284
2022
Applications
Unspecified application
Species
Unspecified reactive species
International journal of molecular sciences 23: PubMed36012579
2022
Applications
Unspecified application
Species
Unspecified reactive species
ACS nano 16:12695-12710 PubMed35939651
2022
Applications
Unspecified application
Species
Unspecified reactive species
Quantitative imaging in medicine and surgery 12:3300-3313 PubMed35655844
2022
Applications
Unspecified application
Species
Unspecified reactive species
Abcam product promise
Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.
For licensing inquiries, please contact partnerships@abcam.com