アブカムでは最適な動作のために Google Chrome など最新ブラウザでの閲覧を推奨します。

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
お問い合わせは電話 03-4571-1344 または メールでどうぞ

  • アカウント
  • ログアウト
ログイン または 新規登録

Welcome

ログイン または

すでにアカウントをお持ちですか?

新規登録
カート
クイック・オーダー
Abcam homepage

  • 研究用製品
    製品タイプ別
    一次抗体
    二次抗体
    イムノアッセイキット・試薬
    細胞・組織イメージング
    細胞・バイオケミカルアッセイ
    製品タイプ別
    タンパク質・ペプチド
    プロテオミクス
    アゴニスト・アクチベータ-・アンタゴニスト・インヒビター
    細胞株・ライゼート
    マルチプレックス・アッセイ
    研究分野別
    癌
    循環器系
    細胞生物学
    エピジェネティクス
    メタボリズム
    発生生物学
    研究分野別
    免疫学
    微生物学
    脳神経科学
    シグナル伝達
    ステムセル
  • カスタム製品 & パートナーシップ
    カスタム製品 & パートナーシップ

    診断や治療プログラムを加速するための、カスタム製品および商業化に向けたパートナーシップ

    カスタム製品

    私たちとパートナーになる

  • サポート
    サポートハブ

    研究のためのサポートとアドバイス

    サポートハブを表示

    プロトコール

    実験のステップごとの詳細

    プロトコールを表示

  • イベント
    • イベント・カレンダー
    • 癌
    • 循環器
    • エピジェネティクス&核内情報
    • 免疫学
    • ニューロサイエンス
    • ステムセル
    • 展示会
    • ウェビナー
    最新のイベント情報

    世界中でアブカムが主催する研究会やセミナーの日程、内容、演者など

    イベント・カレンダー

  • パスウェイ
    細胞シグナル伝達パスウェイ

    すべてのパスウェイを見る

    インタラクティブ・パスウェイを見る

  1. Link

    products/elispot-kits/mouse-interferon-gamma-elispot-kit-ab64029.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Immunology Innate Immunity Cytokines Interferons
Share by email

Mouse Interferon gamma ELISPOT Kit (ab64029)

  • Datasheet
  • SDS
  • Protocol Booklet
Submit a review Q&A (6)References (8)

Product price, shipping and contact information

Currently unavailable

申し訳ございませんが、現在表示できません。

こちらにお問い合わせいただくか、またはしばらく経ってから改めてお試しください

 

Loading size & price…

 

出荷および受注について

Shipping info

Promotion Information

Abpromise

保証された製品品質、優れたカスタマー・サポート。 詳細はこちら。

Key features and details

  • Assay type: Sandwich (qualitative)
  • Detection method: Colorimetric
  • Sample type: Suspension cells
  • Reacts with: Mouse

こちらの製品もご検討ください

ELISA
Product image
Mouse IgG ELISA Kit (ab151276)
タンパク質
Product image
Recombinant mouse Interferon gamma protein (Active) (ab259378)
タンパク質
Product image
Recombinant Rabbit IL-2 Protein (Active) (ab307411)

関連製品

製品の概要

  • 製品名

    Mouse Interferon gamma ELISPOT Kit
    Interferon gamma キット 製品一覧
  • 検出方法

    Colorimetric
  • サンプルの種類

    Suspension cells
  • アッセイタイプ

    Sandwich (qualitative)
  • ステップ

    Multiple steps standard assay
  • 種交差性

    交差種: Mouse
  • 製品の概要

    The ELISPOT assay is designed to enumerate cytokine producing cells in a single cell suspension. This method has the advantage of requiring a minimum of in-vitro manipulations allowing cytokine production analysis as close as possible to in-vivo conditions in a highly specific way. This technique is designed to determine the frequency of cytokine producing cells under a given stimulation, and the follow-up of such frequency during a treatment and/or a pathological state. Elispot assay constitutes an ideal tool in the TH1 / TH2 response, vaccine development, viral infection monitoring and treatment, cancerology, infectious diseases, autoimmune diseases and transplantation.


    Abcam Elispot assay is based on sandwich immuno-enzyme technology. Cell secreted cytokines or soluble molecules are captured by coated antibodies avoiding diffusion in supernatant, protease degradation or binding on soluble membrane receptors. After cell removal, the captured cytokines are revealed by tracer antibodies and appropriate conjugates.


    Principle


    After cell stimulation, locally produced cytokines are captured by a specific monoclonal antibody. After cell lysis, trapped cytokine molecules are revealed by a secondary biotinylated detection antibody, which is in turn recognised by streptavidin conjugated to alkaline phosphatase. PVDF-bottomed-well plates are then incubated with BCIP/NBT substrate. Colored "purple" spots indicate cytokine production by individual cells.


     


    Recognizes natural murine Interferon gamma.

  • アプリケーション

    適用あり: ELISpotmore details
  • 試験プラットフォーム

    Microplate

製品の特性

  • 保存方法

    Store at +4°C. Please refer to protocols.
  • 内容 1 x 96 tests 5 x 96 tests
    Bovine Serum Albumin 1 x 2g 1 x 2g
    IFNγ Biotinylated detection antibody 1 x 100µl 1 vial
    Mouse IFNγ Pre-coated 96-well PVDF-bottomed plates 1 unit 5 units
    Ready-to-use BCIP/NBT substrate buffer 1 x 11ml 2 x 25ml
    Streptavidin - Alkaline Phosphatase conjugated 1 x 10µl 1 x 50µl
  • 研究分野

    • Immunology
    • Innate Immunity
    • Cytokines
    • Interferons
    • Stem Cells
    • Signaling Pathways
    • TGF beta
    • Interferon gamma
    • Cancer
    • Tumor immunology
    • Cytokines
    • Interferons
    • Immunology
    • Adaptive Immunity
    • Regulatory T Cells
    • Kits/ Lysates/ Other
    • Kits
    • ELISPOT and FLUOROSPOT Kits
    • ELISPOT Kits
    • Interferon ELISPOT kits
    • Neuroscience
    • Processes
  • 機能

    Produced by lymphocytes activated by specific antigens or mitogens. IFN-gamma, in addition to having antiviral activity, has important immunoregulatory functions. It is a potent activator of macrophages, it has antiproliferative effects on transformed cells and it can potentiate the antiviral and antitumor effects of the type I interferons.
  • 組織特異性

    Released primarily from activated T lymphocytes.
  • 関連疾患

    In Caucasians, genetic variation in IFNG is associated with the risk of aplastic anemia (AA) [MIM:609135]. AA is a rare disease in which the reduction of the circulating blood cells results from damage to the stem cell pool in bone marrow. In most patients, the stem cell lesion is caused by an autoimmune attack. T-lymphocytes, activated by an endogenous or exogenous, and most often unknown antigenic stimulus, secrete cytokines, including IFN-gamma, which would in turn be able to suppress hematopoiesis.
  • 配列類似性

    Belongs to the type II (or gamma) interferon family.
  • 翻訳後修飾

    Proteolytic processing produces C-terminal heterogeneity, with proteins ending alternatively at Gly-150, Met-157 or Gly-161.
  • 細胞内局在

    Secreted.
  • Target information above from: UniProt accession P01579 The UniProt Consortium
    The Universal Protein Resource (UniProt) in 2010
    Nucleic Acids Res. 38:D142-D148 (2010) .

    Information by UniProt
  • 別名

    • IF 1
    • IFG
    • IFI
    • ifn g
    • IFN gamma
    • IFN immune
    • IFN, immune
    • IFN-gamma
    • IFNG
    • IFNG_HUMAN
    • Immune interferon
    • Interferon gamma
    • Type II Interferon
    see all
  • 参照データベース

    • Entrez Gene: 15978 Mouse
    • SwissProt: P01580 Mouse
    • Unigene: 240327 Mouse

    アプリケーション

    The Abpromise guarantee

    Abpromise保証は、 次のテスト済みアプリケーションにおけるab64029の使用に適用されます

    アプリケーションノートには、推奨の開始希釈率がありますが、適切な希釈率につきましてはご検討ください。

    アプリケーション Abreviews 特記事項
    ELISpot
    Use at an assay dependent dilution.
    特記事項
    ELISpot
    Use at an assay dependent dilution.

    プロトコール

    • Protocol Booklet

    Click here to view the general protocols

    データシートおよび資料

    • SDS download

    • Datasheet download

      Download

    参考文献 (8)

    ab64029 を使用した論文を発表された方は、こちらまでお知らせください。データシートに掲載させていただきます。

    ab64029 は 8 報の論文で使用されています。

    • Tregoning JS  et al. Formulation, inflammation, and RNA sensing impact the immunogenicity of self-amplifying RNA vaccines. Mol Ther Nucleic Acids 31:29-42 (2023). PubMed: 36589712
    • Fu Y & Xiong S Exosomes mediate Coxsackievirus B3 transmission and expand the viral tropism. PLoS Pathog 19:e1011090 (2023). PubMed: 36634130
    • Hoang HD  et al. Adaptation of transgene mRNA translation boosts the anticancer efficacy of oncolytic HSV1. J Immunother Cancer 11:N/A (2023). PubMed: 36958764
    • Tai W  et al. An mRNA-based T-cell-inducing antigen strengthens COVID-19 vaccine against SARS-CoV-2 variants. Nat Commun 14:2962 (2023). PubMed: 37221158
    • Wang Z  et al. Reducing cell intrinsic immunity to mRNA vaccine alters adaptive immune responses in mice. Mol Ther Nucleic Acids 34:102045 (2023). PubMed: 37876532
    • Chen J  et al. Lipid nanoparticle-mediated lymph node-targeting delivery of mRNA cancer vaccine elicits robust CD8+ T cell response. Proc Natl Acad Sci U S A 119:e2207841119 (2022). PubMed: 35969778
    • Zhou S  et al. FAP-Targeted Photodynamic Therapy Mediated by Ferritin Nanoparticles Elicits an Immune Response against Cancer Cells and Cancer Associated Fibroblasts. Adv Funct Mater 31:N/A (2021). PubMed: 35822179
    • Liu Z  et al. Detecting Tumor Antigen-Specific T Cells via Interaction-Dependent Fucosyl-Biotinylation. Cell 183:1117-1133.e19 (2020). PubMed: 33096019

    レビューと Q&A

    Show All レビュー Q&A
    レビューを送る 質問を送る

    1-6 of 6 Abreviews or Q&A

    Question

    Does this kit contain a single 96 well plate or 12, 8 well strips?

    Read More

    Abcam community

    Verified customer

    Asked on Nov 10 2014

    Answer

    This kit ships with whole 96 wells plates, not 12, 8-well strips.

    Read More

    Jeremy Kasanov

    Abcam Scientific Support

    Answered on Nov 10 2014

    Question

    One of our customer want to use ab64029 for mouse serum sample.
    Does this product suitable for the same? If no, do we have suitable
    product for the same ?

    Read More

    Abcam community

    Verified customer

    Asked on Mar 05 2013

    Answer



    Unfortunately, this kit is a ELISpot assay dedicated to detect IFNg secreting cells and not appropriate for serum.

    This product will work for your customer's samples:

    https://www.abcam.com/Mouse-Interferon-gamma-ELISA-Kit-ab46081.html (or use the following: https://www.abcam.com/Mouse-Interferon-gamma-ELISA-Kit-ab46081.html).


    Read More

    Abcam Scientific Support

    Answered on Mar 05 2013

    Question

    Thanks for replying. I'm sorry for confusing, both of Kit's manuals were setting on my desk when i was writing to you the email.
    For kit ab64029 ELISPOT , I would like you to see if the protocol of the cells preparation was OK. I noticed at the end of the experiment (ELISPOT) that I got few purple spots! The colour was not sharp though and it is hard to count the spots manually. I follow the protocol without any possibility of mixing with the another kit.
    For kit number ab46081, I did not say biotinylated detection antibody HRP, quote from pervious email (the problem was when I used the concentration of streptaviden –HRP that reported in the protocol). What I did was when I increased the concentration of streptaviden –HRP, this improved the results for me and i got reasonable results that were coordinated with other experiments I did. I assume that Strep_HRP that is recommended in the protocol was too low.
    I'm pretty sure that I’m following the instructions that you sent with the both protocols
    Your help will be appreciated

    Best regards

    Read More

    Abcam community

    Verified customer

    Asked on Aug 17 2012

    Answer

    Thank you for contacting us.

    The collaborator lab who devolved this kit have suggested using the following stimulation protocol :
    Pre-stimulation of splenocytes by ConA (0.5µg/ml) + murine IL-2 (2ng/ml) 24h (or 48h), then addition of PMA (1ng/ml) and iono (500ng/ml).

    I am sure with proper stimulation the kit ab64029 will be able to detect the high intensity spots.

    We have received no complaint for ab46081 and the kit is optimized with the mentioned dilution of HRP. So I am sorry we are not aware if the recommended dilution is low. We will indeed investigate it if we get more complaints.

    I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

    Use our products? Submit an Abreview. Earn rewards!
    https://www.abcam.com/abreviews

    Read More

    Abcam Scientific Support

    Answered on Aug 17 2012

    Question

    sorry for being late to response. I was extremely busy writing and working in the same time. I sent my feedback but unfortunately the analysis of ELISPOT interferon did not work out! I'm attaching for you the protocol i used to prepare my cells. Then I followed the protocol you sent me with the kit.

    Moreover, I used ELISA kit to quantify interferon gamma (ab64029) and i faced someproblem with it. The problem was when I used the concentration of streptaviden –HRP that reported in the protocol , samples did not did gave me any reading and that was obvious from low strength of the colour ! then i did this experiment again with changing the concentration of the streptvi-HRP and i worked for me. Then again I followed the protocol as u advised me after calling technical support and i used the same concentration you recommend in the protocol . The result was it did not work for all samples even +ve control where i used Con A. I did not have any ELISA kit left and I’m assuming that the concentration of strep-HRP is too diluted. I hope you can help in this

    I really appricate all your privious helps and i'm looking forward for advice and help here.

    Best regards

    Read More

    Abcam community

    Verified customer

    Asked on Aug 14 2012

    Answer

    Thank you for your email.

    Peter is in feedback department. They do not deal with technical inquiries. I have been assigned your case and I will be following up now on. I have checked your previous contacts with my colleagues it seems you have problems with multiple kits. However I will be following this as a fresh complaint so please provide the requested information.

    You have kindly submitted complaint for ab64029, which is ELISPOT kit however the protocol you have submitted as attachment is for ab46081. Could you clarify which kit to focus for this complaint?

    The antibody in kit ab64029 is biotinylated with AP-streptavidin conjugated. It is not a HRP conjugated antibody so could you specify exactly what procedure you followed.

    Am I right in saying the protocol of ab64029 and ab46081 were mixed without realizing different components. I might be wrong could you specify the details.

    Many thanks for your cooperation in advance. I will look forward to hearing from you soon.

    Read More

    Abcam Scientific Support

    Answered on Aug 14 2012

    Question

    phone call - no secreting cells detected

    Read More

    Abcam community

    Verified customer

    Asked on May 18 2012

    Answer

    Thank you for calling us.

    I am very sorry that we had so many problems sending you the emails. I am happy that it seems to work now.

    I apologize also that our phone call got cut. Please do not hesitate to call back.

    As we discussed on the phone, we would be pleased to look through the protocol to see whether we could suggest some optimisation tips. I amattaching thereforeour questionnaire so that we can gather further information regarding the samples tested and the protocol used. Please describe well the sample preparation. Once we receive the completed questionnaire, we will look at the protocol and see if there are any suggestions we can make that may improve the results.

    I look forward to receiving your reply.

    Also, the catalogue numberof the mouse IL-4 ELISA Kit is ab100710. https://www.abcam.com/Mouse-IL-4-ELISA-Kit-ab100710.html (or use the following: https://www.abcam.com/Mouse-IL-4-ELISA-Kit-ab100710.html).

    Please let us know if you have any question.

    I wish you a great weekend!

    Read More

    Abcam Scientific Support

    Answered on May 18 2012

    Question

    received two pre-coated plates instead of strips.

    Read More

    Abcam community

    Verified customer

    Asked on May 09 2012

    Answer

    Thank youfor your phone call yesterday.

    I am very sorry for the error on our datasheet in regards to the plate format. I have investigated this issue with my colleagues, and indeed, the kit ab64029 comes onlywith one 96 well plate. we have updated now the datasheet.I am very sorry for this error and the confusion generated. Unfortunately we do not have this Elispot kit with stripes.

    I will be happy to send youan additional kit free of charge, so youcan perform more experiments.Unfortunately I do not know what I could do else to help you.

    Maybe you can try to group the experiences? Also, it might be possible to use the free wells in the plate, even though the plate has been incubated. As said though on the telephone, I would not have recommended this. Indeed, this is not the intended use and it might not work. If you can include however the appropriate controls, you could assess whether it still works.

    I am sorry for not being able to be more helpful. Please let me know if you have any questions or concerns and if you accept the free kit.

    I am looking forward to hear back from you.

    Read More

    Abcam Scientific Support

    Answered on May 09 2012

    Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
    For licensing inquiries, please contact partnerships@abcam.com

    技術情報や製品情報をメールで受け取る 登録
    製品・研究分野別
    • 癌
    • 循環器
    • 細胞生物学
    • 発生
    • エピジェネティクス&核内情報
    • 免疫学
    • メタボリズム
    • 感染症
    • ニューロサイエンス
    • シグナル伝達
    • ステムセル
    製品・タイプ別
    • 一次抗体
    • 二次抗体
    • バイオケミカルズ
    • アイソタイプ・コントロール
    • マルチカラー・セレクター
    • キット
    • ローディング・コントロール
    • ライゼート
    • ペプチド
    • タンパク質
    • スライド
    • タグ抗体・細胞マーカー
    • その他試薬
    サービス&サポート
    • サポート
    • よくあるお問い合わせ
    • プロトコール&トラブルシュート
    • ご購入に関して
    • お問い合わせフォーム
    • トレーニング
    • ターゲット別に見る
    アブカムについて
    • 企業ウェブサイト
    • 投資家の皆様へ
    • 企業情報
    • 採用情報
    • アブカムについて
    イベント
    • 展示会
    • カンファレンス
    International websites
    • abcam.com
    • abcam.cn

    Join with us

    • LinkedIn
    • facebook
    • Twitter
    • YouTube
    • Terms of sale
    • Website terms of use
    • Cookie policy
    • Privacy policy
    • Legal
    © 1998-2025 Abcam plc. All rights reserved.