Human GLP-1 (7-36) ELISA Kit, Fluorescent (ab229413)
Key features and details
- One-wash 90 minute protocol
- Sensitivity: 12 pg/ml
- Range: 14.6 pg/ml - 1000 pg/ml
- Sample type: Cell culture supernatant, Cit plasma, Hep Plasma, Serum
- Detection method: Fluorescent
- Assay type: Sandwich (quantitative)
- Reacts with: Human
製品の概要
-
製品名
Human GLP-1 (7-36) ELISA Kit, Fluorescent
GLP-1 キット 製品一覧 -
検出方法
Fluorescent -
再現性
Intra-Assay(同時再現性) サンプル N 平均値 SD CV% human serum 8 7% Inter-Assay(日差再現性) サンプル N 平均値 SD CV% human serum 3 9% -
サンプルの種類
Cell culture supernatant, Serum, Hep Plasma, Cit plasma -
アッセイタイプ
Sandwich (quantitative) -
検出感度
12 pg/ml -
検出範囲
14.6 pg/ml - 1000 pg/ml -
添加回収試験
特定サンプルでの回収試験 サンプルの種類 平均 % 測定範囲 Cell culture supernatant 99 93% - 102% Serum 109 105% - 112% Hep Plasma 110 104% - 112% Cit plasma 115 107% - 123% -
全工程の試験時間
1h 30m -
ステップ
One step assay -
種交差性
交差種: Human
交差が予測される動物種: Sheep, Horse, Cow, Pig -
製品の概要
GLP-1 (7-36) in vitro CatchPoint SimpleStep ELISA (Enzyme-Linked Immunosorbent Assay) kit is designed for the quantitative measurement of GLP-1 (7-36) protein in human serum, plasma, and cell culture supernatants.
This CatchPoint SimpleStep ELISA kit has been optimized for Molecular Devices Microplate Readers. Click here for a list of recommended Microplate Readers.
If using a Molecular Devices’ plate reader supported by SoftMax® Pro software, a preconfigured protocol for these CatchPoint SimpleStep ELISA Kits is available with all the protocol and analysis settings at www.softmaxpro.org.
The CatchPoint SimpleStep ELISA employs an affinity tag labeled capture antibody and a reporter conjugated detector antibody which immunocapture the sample analyte in solution. This entire complex (capture antibody/analyte/detector antibody) is in turn immobilized via immunoaffinity of an anti-tag antibody coating the well. To perform the assay, samples or standards are added to the wells, followed by the antibody mix. After incubation, the wells are washed to remove unbound material. CatchPoint HRP Development Solution containing the Stoplight Red Substrate is added. During incubation, the substrate is catalyzed by HRP generating a fluorescent product. Signal is generated proportionally to the amount of bound analyte and the intensity is measured in a fluorescence plater reader at 530/570/590 nm Excitation/Cutoff/Emission.
-
特記事項
GLP-1 (Glucagon like peptide 1) is part of the group of incretin hormones that are secreted by the gastrointestinal tract in response to food intake to assist glucose stimulated insulin secretion and glucagon suppression. GLP-1 is a 30 aminoacid peptide cleaved from proglucagon and released by the L-cells of the distal ileum. The intracellular precursor of GLP-1 (1-37) is cleaved to form the active peptides GLP-1 (7-37) and GLP-1 (7-36)NH2. The active peptides bind to the GLP-1 receptor (GLP-1r) expressed in the pancreatic beta cell and are quickly metabolized by the enzyme dipeptidyl peptidase IV (DPP-IV) to form the peptide GLP-1 (9-36), which has no insulin stimulating activity. Binding of active GLP-1 to the receptor, increases cAMP levels and potentiates insulin secretion via Protein Kinase A (PKA) and the cAMP-regulated nucleotide exchange factor (Epac2). GLP-1 and its receptor are also suggested to play a role in the central nervous systems as mediators of satiety. Intracerebroventricular GLP-1 has been shown to induce c-FOS activity in the hypothalamus and the central nucleus of the amygdala, both of which are important in the regulation of appetite.
The role of GLP-1 in chronic diseases is controversial. Patients with type-II diabetes as well as morbidly obese subjects have been shown to have lower secretion of post-prandial GLP-1, which improves with treatment or weight loss. Due to the beneficial effects of active GLP-1 as well as GLP-1r agonists in metabolic diseases, GLP-1 has been proposed to be an effective therapeutic approach to lowering glycemic levels and decreasing body fat content. Furthermore, GLP-1 has been found to be cardioprotective during acute myocardial infarction. In contrast with the GLP-1 protective findings, circulating GLP-1 has also been found to positively correlate with serum triclycerides and high levels are significantly associated with coronary plaque burden in patients receiving coronary CT-angiography.
-
アプリケーション
適用あり: Sandwich ELISAmore details -
試験プラットフォーム
Pre-coated microplate (12 x 8 well strips)
製品の特性
-
保存方法
Store at +4°C. Please refer to protocols. -
内容 1 x 96 tests 100X Stoplight Red Substrate 1 x 120µl 10X Human GLP1 (7-36) Capture Antibody 1 x 600µl 10X Human GLP1 (7-36) Detector Antibody 1 x 600µl 10X Wash Buffer PT (ab206977) 1 x 20ml 500X Hydrogen Peroxide (H2O2, 3%) 1 x 50µl Antibody Diluent CPI - HAMA Blocker (ab193969) 1 x 6ml Human GLP1 Lyophilized Recombinant Protein 2 vials Plate Seal 1 unit Sample Diluent NS (ab193972) 1 x 50ml SimpleStep Pre-Coated Black 96-Well Microplate 1 unit Stoplight Red Substrate Buffer 1 x 12ml -
研究分野
-
機能
Glucagon plays a key role in glucose metabolism and homeostasis. Regulates blood glucose by increasing gluconeogenesis and decreasing glycolysis. A counterregulatory hormone of insulin, raises plasma glucose levels in response to insulin-induced hypoglycemia. Plays an important role in initiating and maintaining hyperglycemic conditions in diabetes.
GLP-1 is a potent stimulator of glucose-dependent insulin release. Play important roles on gastric motility and the suppression of plasma glucagon levels. May be involved in the suppression of satiety and stimulation of glucose disposal in peripheral tissues, independent of the actions of insulin. Have growth-promoting activities on intestinal epithelium. May also regulate the hypothalamic pituitary axis (HPA) via effects on LH, TSH, CRH, oxytocin, and vasopressin secretion. Increases islet mass through stimulation of islet neogenesis and pancreatic beta cell proliferaton. Inhibits beta cell apoptosis.
GLP-2 stimulates intestinal growth and up-regulates villus height in the small intestine, concomitant with increased crypt cell proliferation and decreased enterocyte apoptosis. The gastrointestinal tract, from the stomach to the colon is the principal target for GLP-2 action. Plays a key role in nutrient homeostasis, enhancing nutrient assimilation through enhanced gastrointestinal function, as well as increasing nutrient disposal. Stimulates intestinal glucose transport and decreases mucosal permeability.
Oxyntomodulin significantly reduces food intake. Inhibits gastric emptying in humans. Suppression of gastric emptying may lead to increased gastric distension, which may contribute to satiety by causing a sensation of fullness.
Glicentin may modulate gastric acid secretion and the gastro-pyloro-duodenal activity. May play an important role in intestinal mucosal growth in the early period of life. -
組織特異性
Glucagon is secreted in the A cells of the islets of Langerhans. GLP-1, GLP-2, oxyntomodulin and glicentin are secreted from enteroendocrine cells throughout the gastrointestinal tract. GLP1 and GLP2 are also secreted in selected neurons in the brain. -
配列類似性
Belongs to the glucagon family. -
翻訳後修飾
Proglucagon is post-translationally processed in a tissue-specific manner in pancreatic A cells and intestinal L cells. In pancreatic A cells, the major bioactive hormone is glucagon cleaved by PCSK2/PC2. In the intestinal L cells PCSK1/PC1 liberates GLP-1, GLP-2, glicentin and oxyntomodulin. GLP-1 is further N-terminally truncated by post-translational processing in the intestinal L cells resulting in GLP-1(7-37) GLP-1-(7-36)amide. The C-terminal amidation is neither important for the metabolism of GLP-1 nor for its effects on the endocrine pancreas. -
細胞内局在
Secreted. - Information by UniProt
-
別名
- GCG
- Glicentin related polypeptide
- glicentin-related polypeptide
see all -
参照データベース
- Entrez Gene: 280802 Cow
- Entrez Gene: 2641 Human
- Entrez Gene: 397595 Pig
- Omim: 138030 Human
- SwissProt: P01272 Cow
- SwissProt: P01275 Human
- SwissProt: P01274 Pig
- Unigene: 516494 Human
アプリケーション
The Abpromise guarantee
Abpromise保証は、 次のテスト済みアプリケーションにおけるab229413の使用に適用されます
アプリケーションノートには、推奨の開始希釈率がありますが、適切な希釈率につきましてはご検討ください。
アプリケーション | Abreviews | 特記事項 |
---|---|---|
Sandwich ELISA |
Use at an assay dependent concentration.
|
特記事項 |
---|
Sandwich ELISA
Use at an assay dependent concentration. |
画像
-
SimpleStep ELISA technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 90 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.
-
Example of human GLP-1 (7-36) standard curve in Sample Diluent NS. The GLP-1 (7-36) standard curve was prepared as described in Section 10.
-
Serum of each donor was diluted 1:10 using sample diluent NS. The mean levels of GLP-1, after adjusting for dilution factor, were found at 433.5 pg/mL with a standard deviation of 277 pg/mL.
-
To learn more about the advantages of recombinant antibodies see here.
データシートおよび資料
-
SDS download
-
Datasheet download
参考文献 (2)
ab229413 は 2 報の論文で使用されています。
- Ataeinosrat A et al. Effects of Three Different Modes of Resistance Training on Appetite Hormones in Males With Obesity. Front Physiol 13:827335 (2022). PubMed: 35264977