JavaScript is disabled in your browser. Please enable JavaScript to view this website.
AB315318

Human CD146 ELISA Kit

Human CD146 ELISA Kit

Be the first to review this product! Submit a review

|

(0 Publication)

Human CD146 ELISA Kit is a single-wash 90-min Simplestep used to quantify Human CD146 with a sensitivity of 12.476 pg/ml. The assay uses a simple mix-wash-read protocol with just one incubation and one wash step.

- Colorimetric Sandwich ELISA - 450 nm readout : works on any standard plate reader
- Validated on a number of sample types including cerebrospinal fluid (CSF)
- Design your own immunoassay: we also offer the conjugation-ready antibody pair

別名を表示する

CD146, MUC18, MCAM, Cell surface glycoprotein MUC18, Cell surface glycoprotein P1H12, Melanoma cell adhesion molecule, Melanoma-associated antigen A32, Melanoma-associated antigen MUC18, S-endo 1 endothelial-associated antigen

4 Images
Sandwich ELISA - Human CD146 ELISA Kit (AB315318)
  • sELISA

Supplier Data

Sandwich ELISA - Human CD146 ELISA Kit (AB315318)

Interpolated concentrations of human CD146 in HeLa cell culture supernatant

Interpolated concentration of native CD146 was measured in duplicate at different sample concentrations. Undiluted samples are as follows : HeLa cell culture supernatant 50%.  The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). Sample dilutions are made in Sample Diluent NS.

Sandwich ELISA - Human CD146 ELISA Kit (AB315318)
  • sELISA

Supplier Data

Sandwich ELISA - Human CD146 ELISA Kit (AB315318)

Interpolated concentrations of human CD146 in serum, plasma (citrate), plasma (EDTA), plasma (Heparin), and CSF

Interpolated concentration of native CD146 was measured in duplicate at different sample concentrations. Undiluted samples are as follows : serum 1 : 400, plasma (citrate) 1 : 400, plasma (EDTA) 1 : 400, plasma (heparin) 1 : 400, and CSF 1 : 50. The interpolated dilution factor corrected values (to neat sample) are plotted (mean +/- SD, n=2). Sample dilutions are made in Sample Diluent NS.

Sandwich ELISA - Human CD146 ELISA Kit (AB315318)
  • sELISA

Supplier Data

Sandwich ELISA - Human CD146 ELISA Kit (AB315318)

Interpolated concentrations of CD146 in normal human serum donors

Serum of ten individual healthy human female donors was measured in duplicate. Interpolated dilution factor corrected values are plotted (mean +/- SD, n=2). The mean CD146 concentration was determined to be 304 ng/mL with a range of 228 – 486 ng/mL.

Sandwich ELISA - Human CD146 ELISA Kit (AB315318)
  • sELISA

Supplier Data

Sandwich ELISA - Human CD146 ELISA Kit (AB315318)

Example of human CD146 standard curve in Sample Diluent NS. Background-subtracted data values (mean +/- SD) are graphed.

Key facts

検出方法

Colorimetric

サンプルタイプ

Serum, EDTA Plasma, Citrate plasma, Heparin Plasma, Cerebral Spinal Fluid, Cell culture supernatant

交差種

Human

アッセイタイプ

Sandwich

検出感度

= 12.476 pg/mL

検出範囲

25 - 1600 pg/mL

アッセイ時間

1h 30m

アッセイプラットフォーム

Pre-coated microplate (12 x 8 well strips)

Reactivity data

{ "title": "Reactivity Data", "filters": { "stats": ["", "Reactivity", "Dilution Info", "Notes"] }, "values": { "sELISA": { "reactivity":"TESTED_AND_REACTS", "dilution-info":"", "notes":"<p></p>" } } }

製品の詳細

Human CD146 SimpleStep ELISA® kit is a single-wash 90 min sandwich ELISA designed for the quantitative measurement of CD146 protein in Serum, EDTA Plasma, Cit Plasma, Hep Plasma, Cerebral Spinal Fluid, and Cell culture supernatant. Quantitate Human CD146 with 12.476 pg/ml sensitivity.

SimpleStep ELISA® technology employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step, significantly reducing assay time. See the SimpleStep ELISA® protocol summary in the image section for further details. Our SimpleStep ELISA® technology provides several benefits:

-Single-wash protocol reduces assay time to 90 minutes or less
-High sensitivity, specificity and reproducibility from superior antibodies
-Fully validated in biological samples
-96-wells plate breakable into 12 x 8 wells strips

A 384-well SimpleStep ELISA® microplate (ab315065) is available to use as an alternative to the 96-well microplate provided with SimpleStep ELISA® kits.

精度

[ { "reproducibilityType": "Intra", "sample": "Serum", "replicates": 8, "mean": null, "standardDeviation": null, "coefficientOfVariability": "= 7.7" }, { "reproducibilityType": "Inter", "sample": "Serum", "replicates": 3, "mean": null, "standardDeviation": null, "coefficientOfVariability": "= 9.5" } ]

回収率

[ { "sample": "Serum", "range": "89 - 100 %", "average": "= 93" }, { "sample": "EDTA Plasma", "range": "79 - 94 %", "average": "= 89" }, { "sample": "Citrate plasma", "range": "105 - 117 %", "average": "= 111" }, { "sample": "Heparin Plasma", "range": "94 - 104 %", "average": "= 99" }, { "sample": "Cerebral Spinal Fluid", "range": "76 - 98 %", "average": "= 88" }, { "sample": "Cell culture supernatant", "range": "93 - 110 %", "average": "= 103" } ]

製品内容

{ "values": { "1x96Tests": { "sellingSize": "1 x 96 Tests", "publicAssetCode":"ab315318-1x96Tests", "assetComponentDetails": [ { "size":"1 x 12 mL", "name":"Stop Solution", "number":"AB315318-CMP08", "productcode":"" }, { "size":"1 x 50 mL", "name":"Sample Diluent NS (ab193972)", "number":"AB315318-CMP06", "productcode":"" }, { "size":"1 x 12 mL", "name":"TMB Development Solution", "number":"AB315318-CMP07", "productcode":"" }, { "size":"1 x 20 mL", "name":"10X Wash Buffer PT (ab206977)", "number":"AB315318-CMP05", "productcode":"" }, { "size":"1 x 600 µL", "name":"10X Human CD146 Capture Antibody", "number":"AB315318-CMP01", "productcode":"" }, { "size":"2 x 1 Vial", "name":"Human CD146 Lyophilized Recombinant Protein", "number":"AB315318-CMP03", "productcode":"" }, { "size":"1 x 6 mL", "name":"Antibody Diluent 4BI", "number":"AB315318-CMP04", "productcode":"" }, { "size":"1 x 600 µL", "name":"10X Human CD146 Detector Antibody", "number":"AB315318-CMP02", "productcode":"" }, { "size":"1 x 1 Unit", "name":"SimpleStep Pre-Coated 96-Well Microplate (ab206978)", "number":"AB315318-CMP09", "productcode":"" }, { "size":"1 x 1 Unit", "name":"Plate Seals", "number":"AB315318-CMP10", "productcode":"" } ] } } }

出荷温度及び保存条件

出荷温度
Blue Ice
短期保存温度
+4°C
長期保存温度
+4°C
保管に関する情報
+4°C

補足情報

This supplementary information is collated from multiple sources and compiled automatically.

CD146 also known as MCAM or MUC18 is a cell adhesion molecule that belongs to the immunoglobulin superfamily. With a mass of approximately 113 kDa CD146 is expressed mainly on the surface of endothelial cells but it can also be found on smooth muscle cells some T-cells and in certain cancerous tissues. This protein plays a role in cell-cell adhesion contributing to the integrity and signaling functions within tissue microenvironments.
Biological function summary

CD146 influences the migration and organization of cells within the vascular system. It serves as a component of cell adhesion complexes facilitating interactions between endothelial cells and other cell types. Additionally CD146 contributes to angiogenesis the process by which new blood vessels form from existing vasculature which is critical during tissue development and repair. This function makes it an important element in maintaining normal physiological processes.

Pathways

CD146 participates in the Wnt/β-catenin and MAPK signaling pathways which are vital in cell proliferation and differentiation. Through the Wnt/β-catenin pathway CD146 interacts with other proteins like Frizzled receptors to regulate gene transcription. In the MAPK pathway it is linked with signaling cascades that involve proteins such as ERK leading to cellular responses necessary for growth and response to external stimuli.

CD146 has been implicated in melanoma progression and cardiovascular diseases. Its overexpression in melanoma associates it with increased tumor growth and metastasis often involving interactions with other adhesion molecules like integrins. In cardiovascular diseases CD146 relates to atherosclerosis as its expression on endothelial cells can promote inflammatory responses. Understanding these connections provides insights into potential therapeutic targets for treating these conditions.

製品プロトコール

ターゲットの情報

Plays a role in cell adhesion, and in cohesion of the endothelial monolayer at intercellular junctions in vascular tissue. Its expression may allow melanoma cells to interact with cellular elements of the vascular system, thereby enhancing hematogeneous tumor spread. Could be an adhesion molecule active in neural crest cells during embryonic development. Acts as a surface receptor that triggers tyrosine phosphorylation of FYN and PTK2/FAK1, and a transient increase in the intracellular calcium concentration.
See full target information MCAM
websiteProtocolBooklet
en

Abcam product promise

当社は、高品質な試薬を通じてお客様の研究を力強くサポートすることをお約束いたします。ご使用いただく各段階で、常にお客様をサポートできる体制を整えております。万が一、製品が期待通りに機能しない場合は、「Abcam Product Promise」による当社保証制度に基づき、安心してご利用いただけます。
保証に関する詳細については利用規約をご確認ください。

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com