アブカムでは最適な動作のために Google Chrome など最新ブラウザでの閲覧を推奨します。

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
お問い合わせは電話 03-4571-1344 または メールでどうぞ

  • アカウント
  • ログアウト
ログイン または 新規登録

Welcome

ログイン または

すでにアカウントをお持ちですか?

新規登録
カート
クイック・オーダー
Abcam homepage

  • 研究用製品
    製品タイプ別
    一次抗体
    二次抗体
    イムノアッセイキット・試薬
    細胞・組織イメージング
    細胞・バイオケミカルアッセイ
    製品タイプ別
    タンパク質・ペプチド
    プロテオミクス
    アゴニスト・アクチベータ-・アンタゴニスト・インヒビター
    細胞株・ライゼート
    マルチプレックス・アッセイ
    研究分野別
    癌
    循環器系
    細胞生物学
    エピジェネティクス
    メタボリズム
    発生生物学
    研究分野別
    免疫学
    微生物学
    脳神経科学
    シグナル伝達
    ステムセル
  • カスタム製品 & パートナーシップ
    カスタム製品 & パートナーシップ

    診断や治療プログラムを加速するための、カスタム製品および商業化に向けたパートナーシップ

    カスタム製品

    私たちとパートナーになる

  • サポート
    サポートハブ

    研究のためのサポートとアドバイス

    サポートハブを表示

    プロトコール

    実験のステップごとの詳細

    プロトコールを表示

  • イベント
    • イベント・カレンダー
    • 癌
    • 循環器
    • エピジェネティクス&核内情報
    • 免疫学
    • ニューロサイエンス
    • ステムセル
    • 展示会
    • ウェビナー
    最新のイベント情報

    世界中でアブカムが主催する研究会やセミナーの日程、内容、演者など

    イベント・カレンダー

  • パスウェイ
    細胞シグナル伝達パスウェイ

    すべてのパスウェイを見る

    インタラクティブ・パスウェイを見る

  1. Link

    products/elisa-kits/human-c-reactive-protein-elisa-kit-crp-ab99995.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Immunology Innate Immunity Macrophage / Inflamm.
Share by email

Human C Reactive Protein ELISA Kit (CRP) (ab99995)

  • Datasheet
  • SDS
  • Protocol Booklet
Submit a review Q&A (15)References (36)

Product price, shipping and contact information

Currently unavailable

申し訳ございませんが、現在表示できません。

こちらにお問い合わせいただくか、またはしばらく経ってから改めてお試しください

 

Loading size & price…

 

出荷および受注について

Shipping info

Promotion Information

Abpromise

保証された製品品質、優れたカスタマー・サポート。 詳細はこちら。

Sandwich ELISA- hu CRP (ab99995)
  • Typical Standard Curve

Key features and details

  • Sensitivity: 2 pg/ml
  • Range: 34.29 pg/ml - 25000 pg/ml
  • Sample type: Cell culture supernatant, Plasma, Serum
  • Detection method: Colorimetric
  • Assay type: Sandwich (quantitative)
  • Reacts with: Human

こちらの製品もご検討ください

ELISA
Product image
Human Interferon gamma ELISA Kit (IFNG) (ab100537)
一次抗体
HRP Anti-C Reactive Protein antibody (ab19175)
ELISA
Product image
Human Interferon gamma ELISA Kit (ab300323)

関連製品

製品の概要

  • 製品名

    Human C Reactive Protein ELISA Kit (CRP)
    C Reactive Protein キット 製品一覧
  • 検出方法

    Colorimetric
  • サンプルの種類

    Cell culture supernatant, Serum, Plasma
  • アッセイタイプ

    Sandwich (quantitative)
  • 検出感度

    < 2 pg/ml
  • 検出範囲

    34.29 pg/ml - 25000 pg/ml
  • 添加回収試験

    > 100 %

    特定サンプルでの回収試験
    サンプルの種類 平均 % 測定範囲
    Cell culture supernatant 106.2 95% - 116%
    Serum 116.7 106% - 127%
    Plasma 102.2 93% - 112%
  • ステップ

    Multiple steps standard assay
  • 種交差性

    交差種: Human
  • 製品の概要

    Abcam’s C Reactive Protein (CRP) Human ELISA (Enzyme- Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of Human CRP in serum, plasma, cell culture supernatants.


    This assay employs an antibody specific for Human CRP coated on a 96-well plate. Standards and samples are pipetted into the wells and CRP present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-Human CRP antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of CRP bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm.


    Get results in 90 minutes with Human C Reactive Protein ELISA Kit (ab181416) from our SimpleStep ELISA® range.


     


     

  • 特記事項

    Optimization may be required with urine samples.

  • アプリケーション

    適用あり: Sandwich ELISAmore details
  • 試験プラットフォーム

    Microplate

製品の特性

  • 保存方法

    Store at -20°C. Please refer to protocols.
  • 内容 1 x 96 tests
    20X Wash Buffer 1 x 25ml
    300X HRP-Streptavidin Concentrate 1 x 200µl
    5X Assay Diluent B 1 x 15ml
    5X Assay Diluent D 2 x 15ml
    CRP Microplate (12 x 8 well strips) 1 unit
    Biotinylated anti-Human CRP 2 vials
    Recombinant Human CRP Standard (lyophilized) 2 vials
    Stop Solution 1 x 8ml
    TMB One-Step Substrate Reagent 1 x 12ml
  • 研究分野

    • Immunology
    • Innate Immunity
    • Macrophage / Inflamm.
    • Cardiovascular
    • Blood
    • Acute Phase Reactants
    • Immunology
    • Innate Immunity
    • Complement
    • Classical Pathway
    • Epigenetics and Nuclear Signaling
    • Chromatin Binding Proteins
    • DNA / RNA binding
    • Cardiovascular
    • Atherosclerosis
    • Vascular Inflammation
    • Inflammatory mediators
    • Cardiovascular
    • Heart
    • Apoptosis
    • Kits/ Lysates/ Other
    • Kits
    • ELISA Kits
    • ELISA Kits
    • Apoptosis marker and proteins ELISA kits
    • Kits/ Lysates/ Other
    • Kits
    • ELISA Kits
    • ELISA Kits
    • Complement ELISA kits
    • Kits/ Lysates/ Other
    • Kits
    • ELISA Kits
    • ELISA Kits
    • Blood coagulation ELISA kits
    • Metabolism
    • Types of disease
    • Metabolic disorders
    • Neuroscience
    • Processes
  • 機能

    Displays several functions associated with host defense: it promotes agglutination, bacterial capsular swelling, phagocytosis and complement fixation through its calcium-dependent binding to phosphorylcholine. Can interact with DNA and histones and may scavenge nuclear material released from damaged circulating cells.
  • 組織特異性

    Found in plasma.
  • 配列類似性

    Belongs to the pentaxin family.
    Contains 1 pentaxin domain.
  • 細胞内局在

    Secreted.
  • Target information above from: UniProt accession P02741 The UniProt Consortium
    The Universal Protein Resource (UniProt) in 2010
    Nucleic Acids Res. 38:D142-D148 (2010) .

    Information by UniProt
  • 別名

    • Pentraxin 1, short
    • C reactive protein
    • C reactive protein pentraxin related
    • C-reactive protein(1-205)
    • CRP
    • CRP_HUMAN
    • MGC88244
    • Pentraxin 1
    • PTX 1
    • PTX1
    see all
  • 参照データベース

    • Entrez Gene: 1401 Human
    • Omim: 123260 Human
    • SwissProt: P02741 Human
    • Unigene: 709456 Human
    • Unigene: 76452 Human

    アプリケーション

    The Abpromise guarantee

    Abpromise保証は、 次のテスト済みアプリケーションにおけるab99995の使用に適用されます

    アプリケーションノートには、推奨の開始希釈率がありますが、適切な希釈率につきましてはご検討ください。

    アプリケーション Abreviews 特記事項
    Sandwich ELISA
    Use at an assay dependent concentration.
    特記事項
    Sandwich ELISA
    Use at an assay dependent concentration.

    画像

    • Sandwich ELISA- hu CRP (ab99995)
      Sandwich ELISA- hu CRP (ab99995)

      huCRP measured in biological fluids showing quantity (pg) per mL of sample tested.

    • Typical Standard Curve
      Typical Standard Curve

      Representative Standard Curve using ab99995.

    プロトコール

    • Protocol Booklet

    Click here to view the general protocols

    データシートおよび資料

    • SDS download

    • Datasheet download

      Download

    参考文献 (36)

    ab99995 を使用した論文を発表された方は、こちらまでお知らせください。データシートに掲載させていただきます。

    ab99995 は 36 報の論文で使用されています。

    • Fricker Z  et al. A randomized study of ceftriaxone for the prevention of infections in hospitalized patients with advanced cirrhosis. Hepatol Commun 8:N/A (2024). PubMed: 38180983
    • Abdelrazik E  et al. Beneficial role of rosemary extract on oxidative stress-mediated neuronal apoptosis in rotenone-induced attention deficit hyperactivity disease in juvenile rat model. Acta Biomed 94:e2023104 (2023). PubMed: 37326266
    • AlKassas A  et al. Pre-procedural high serum visfatin and tumor necrosis factor-α might predict recurrent atrial fibrillation after catheter ablation. Egypt Heart J 75:63 (2023). PubMed: 37466800
    • Minas TZ  et al. Serum proteomics links suppression of tumor immunity to ancestry and lethal prostate cancer. Nat Commun 13:1759 (2022). PubMed: 35365620
    • Barcikowska Z  et al. Effect of Manual Therapy Compared to Ibuprofen on Primary Dysmenorrhea in Young Women-Concentration Assessment of C-Reactive Protein, Vascular Endothelial Growth Factor, Prostaglandins and Sex Hormones. J Clin Med 11:N/A (2022). PubMed: 35628817
    View all Publications for this product

    レビューと Q&A

    Show All レビュー Q&A
    レビューを送る 質問を送る

    1-10 of 15 Abreviews or Q&A

    Question


    What is the shelf life of your assay kits?

    Read More

    Abcam community

    Verified customer

    Asked on Feb 12 2013

    Answer


    The shelf life of each of our kits is indicated in the individual protocol booklet.

    ab99995 may be stored for up to 6 months at 2 to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at –80°C) after reconstitution. Opened Microplate Wells or reagents may be store for up to 1 month at 2 to 8°C. Return unused wells to the pouch containing desiccant pack, reseal along entire edge. Note: the kit can be used within one year if the whole kit is stored at -20°C. The same is true for ab100610 and ab113326.

    Read More

    Abcam Scientific Support

    Answered on Feb 12 2013

    Question

    For all those tests that I explained in previous email, I incubate them over night at 4C.
    and dilution for HRP was once 300 fold (as described in the manual) and also when I ran the test
    in parallel with HRP form albumin kit, I diluted 200 fold, but still no changes.

    The data from one of the experiment is attached. this is the one I used the concentrated antibody that I prepared the day before and stored in 4C for further use.

    As you see there is no changes between each Standards and also my samples (A,B, and C) didn't show any response, which
    is not right because my samples have CRP. (all samples including standards are duplicate as 1,2 )

    When I ran this test and I saw no color change on standards (no blue at all) I realized it's probably because of antibody since
    I used the concentrated one stored the day before.

    In previous tests I didn't used the concentrated stored in the fridge and at least I saw slightly color change for 600pg/ml.

    Read More

    Abcam community

    Verified customer

    Asked on Nov 30 2012

    Answer

    The lab sent the following comments and questions. Please let me know if you have the answers to those. I think the lab is trying to understand where exactly the problem might lie.

    But I still think the standard curve should look better than what you had obtained the first time. Could you try the standard curve with the new kits you had sent and maybe a few sample dilutions - just to get some preliminary data?


    Lab response:
    Thank you for the update. In this recent test, none of the absorbances are high enough above background to be considered as real signals. As stated by the customer, this may have been due to using the already reconstituted antibody from the day before. With this being said, the first two tests did show very strong and consistent standard curves. The highest OD reading of ˜1.67 is definitely strong enough for creating a wide enough standard curve to incorporate a range of sample absorbances. Therefore, we do not believe this is a kit or lot related issue. The unfortunate conclusion may be that the amount of CRP in the cell lysate samples is simply too low to be detected by the ELISA kit. I understand the frustration of the customer for not obtaining useful data from the samples and if there truly is high amounts of this protein in the samples, there may be certain sample preparation issues that are contributing to them not being detected.

    How were the HepG2 cells prepared?
    Did the lysis buffer used contain any denaturing or reducing agents?
    How long were the samples stored for before testing?
    Were there any freeze-thaw cycles?



    Thank you so much for your help and understanding.

    Read More

    Abcam Scientific Support

    Answered on Nov 30 2012

    Question

    For all those tests that I explained in previous email, I incubate them over night at 4C.
    and dilution for HRP was once 300 fold (as described in the manual) and also when I ran the test
    in parallel with HRP form albumin kit, I diluted 200 fold, but still no changes.

    The data from one of the experiment is attached. this is the one I used the concentrated antibody that I prepared the day before and stored in 4C for further use.

    As you see there is no changes between each Standards and also my samples (A,B, and C) didn't show any response, which
    is not right because my samples have CRP. (all samples including standards are duplicate as 1,2 )

    When I ran this test and I saw no color change on standards (no blue at all) I realized it's probably because of antibody since
    I used the concentrated one stored the day before.

    In previous tests I didn't used the concentrated stored in the fridge and at least I saw slightly color change for 600pg/ml.

    Read More

    Abcam community

    Verified customer

    Asked on Nov 28 2012

    Answer

    Thank you so much for the additional information. I'll pass it on to the lab.

    Should they have more suggestions, I will let you know.

    I hope the 2 new kits will work as expected.

    Please let me know if you have further questions.

    Read More

    Abcam Scientific Support

    Answered on Nov 28 2012

    Question

    I ran few more tests again based on what your lab recommended.

    1- I used another kit with standards and my samples without dilution :
    Result: same situation as previous kit for STD and still no detection for my samples.
    my samples are high in CRP but still no detection were observed and for STD I got the same range values
    as 1.67 for 600 pg/ml and 0.07 for 66.67 pg/ml and lower concentration plus my samples.
    but no blue color was observed for concentration less than 200pg/ml.

    2- as far as I know if HRP is exposed to the light at room temperature, it turns blue in few minutes.
    this is what usually happen with albumin ELISA kit. But I noticed that when I the HRP form this kit doesn't turn blue
    even after 10min.
    So then I used once HRP from albumin kit (that I had as left over) in parallel with CRP kit.
    Result: still no changes in absorption. Everything was the same as before for STDs and samples

    Then I did the same way for TMB. I used TMB from albumin kit in parallel with CRP kit, but the result was still
    the same, no detection.

    3- The most important thing is I ran the test again with higher concentration of antibody (item F).
    I used the concentrated antibody that I kept in the fridge the day before and diluted 60-fold instead of 80-fold
    But I used the new STDs solution (not the left over kept in the freezer). base on the storage information, the concentrated
    antibody can be stored at 4C for 5 days, but I used it in 48hrs.

    Result: I didn't get any detection at all. For all STDs and samples, there was no change in color , it didn't turn blue at all, even the high concentration STD that I observed before.
    but I still waited for 30min and added the stop solution, and of course nothing.

    The absorbance values for all of them including the samples were 0.03.

    based on these results I believe the problem is either because of the antibody or the treated plates.
    My samples should be high in CRP. The samples are collected media from HepG2 cells treated with cytokines (IL-1b and IL-6)
    in high concentration. But I shouldn't get the same value or even the same range for my samples either, since they were
    also different in some amino acids.

    I wasted 2 kits plus 4 days for nothing. Honestly, I'm not happy at all.
    I'm going to graduate in 3 weeks and this is the last test that I need to do and it was such a wasting time and money.

    Please either consider a refund for 2 kits (one of them is still unused) or replace them with new and
    freshly produced kits. I'm running out of samples too, I cannot waste any more sample.

    Read More

    Abcam community

    Verified customer

    Asked on Nov 26 2012

    Answer

    Thank you for your emails.

    I apologize that I could not get back to you earlier, but our office was closed over the holidays.

    I am very sorry to hear that your effort and attempts to try to get the kits to work were unsuccessful. I will pass your comments on to the lab for their consideration.

    In the meantime, I have arranged for a free of charge replacement for the 2 kits with another, newer lot number. The order number is xxx, and you should receive the 2 kits tomorrow.

    I really hope the new kits will work as expected and they will be helpful for finishing your research before graduation

    Please also do let me know if you have more questions and how the new kits are working for you.

    Best of luck to you!

    Read More

    Abcam Scientific Support

    Answered on Nov 26 2012

    Question

    I confirm our PO 2527 of 11/09/2012.
    So please send us new vial of RP-streptavidin concentrate item.

    Thanks in advance and kind regards

    Read More

    Abcam community

    Verified customer

    Asked on Nov 22 2012

    Answer

    Thank you for confirming these details and for your cooperation. The details provided enable us to closely monitor the quality of our products.

    I am sorry this product did not perform as stated on the datasheet and for the inconvenience this has caused. It has not been possible to obtain the single component of the kit from our source in this case, I have issued a free of charge replacement of the kit with the order number 1208938.

    To check the status of the order please contact our Customer Service team and reference this number.

    Please note that this free of charge replacement vial is also covered by our Abpromise guarantee. Should you still be experiencing difficulties, or if you have any further questions, please do not hesitate to let us know.

    When the new kit is used, it would be beneficial to briefly centrifuge the HRP-streptavidin vial before opening to ensure maximum recovery (Sometimes the liquid can adhere on the sides and cap of the vial).

    Since excess volume of the HRP-streptavidin is provided, please inform the customer that 40ul of the HRP-streptavidin is still more than enough to complete the entire microplate. 40ul X 300 = 12ml of 1X working HRP-streptavidin solution. (Only 9.6ml is needed.) Please encourage the customer to use their current HRP-streptavidin vial and also remind them to centrifuge the vial before opening to ensure maximum recovery (if not doing so already).

    Thank you for your help and cooperation in this case. Please let me know if you have any further questions.

    Read More

    Abcam Scientific Support

    Answered on Nov 22 2012

    Question

    I was just wondering if there is any progress in your investigation or not yet.
    I appreciate if you please let me know as soon as you can, since I need to test my samples
    as soon as it's possible.

    Read More

    Abcam community

    Verified customer

    Asked on Nov 21 2012

    Answer

    Thank you for your patience.
    I have heard back from the lab today with the following response:

    "I am not quite sure what exactly the issue is with the standard curve. I plotted the values in a linear regression model and curve looks fine, see attachment. The highest standard signal strength is strong at ˜1.6 OD, the linearity is high (R2 >0.98), the background is low (0.08 OD), and the duplicate CV is low. Overall I’d say the standard curve is acceptable.

    The customer is missing the 22.22 pg/ml and 7.407 pg/ml standard points though so I would certainly recommend the customer loads these. I’m also a little confused about the ODs for the 6.66 pg/ml and 2.469 pg/ml – were the OD values measured exactly the same value? This seems unlikely.
    The issue to me seems not to be the standard curve but that the sample ODs are very low (0.8 OD) which is below detection, near background. There are a few different options the customer could try in order to get their sample signals within the detectable range of the assay.
    Performing the sample/standard incubation overnight at 4ºC with gently rocking.
    Increase amount of biotinylated detection antibody (by 1.5 fold or so – too much may increase background)
    Increase amount of HRP-streptavidin (by about 1.5 fold or so – too much may increase background)
    Concentrate the sample in a non-denaturing method (for example, using a chilled spin column)

    Please note: it’s best to try just one of these modifications at a time. Implementing too many of these changes at once may cause high background."



    I replied to the lab regarding the standard curve, but please let me know if these tips will be of help and improve your results.

    You might not need to dilute your samples by a factor of 10. Maybe try undiluted samples and a dilution by factor of 2 and 4.

    I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

    Free Rabbit monoclonal antibody with any purchase of a primary antibody, while stocks last! Quote “RABMAB-XBSMG” in your next primary antibody order. For more information, visit the following link: https://www.abcam.com/index.html?pageconfig=resource&rid=15447

    Read More

    Abcam Scientific Support

    Answered on Nov 21 2012

    Question

    antibody vials seem to be empty
    lot GR91493-2 and lot GR95066-1

    Read More

    Abcam community

    Verified customer

    Asked on Nov 20 2012

    Answer

    Thank you for your phone message.

    I have emailed the lab yesterday but have not yet heard back. I will follow up with them today.

    As for the antibody vial:

    Item F detection antibody comes as a very concentrated, small volume liquid. Usually the volume is very small, ˜2ul, so it may be difficult to see. This is why we recommend customers spin down the vial before use to ensure no liquid has adhered to the inside cap or sides of the vial. The small volume is also the reason the biotinylated antibody solution is prepared inside the vial and why the customer should not try to pipette the 1-2ul out.

    I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

    Free Rabbit monoclonal antibody with any purchase of a primary antibody, while stocks last! Quote “RABMAB-XBSMG” in your next primary antibody order. For more information, visit the following link: https://www.abcam.com/index.html?pageconfig=resource&rid=15447

    Read More

    Abcam Scientific Support

    Answered on Nov 20 2012

    Question

    Dear Colleagues,
    a customer of ours bought your AB99995 lot GR91493-2 (our PO 2527), but she found less HRP-streptavidin concentrate (Item G) than expected.
    In fact she found only 40ul instead of 200ul (300X).
    Can you please send us a new vial of HRP-streptavidin concentrate (Item G)?

    Thanks in advance and kind regards

    Read More

    Abcam community

    Verified customer

    Asked on Nov 20 2012

    Answer

    Thank you for your message. I am sorry to hear there was a shortage of the HRP-streptavidin concentrate item in the ab99995 kit.

    If this has been purchased in the last 6 months, I will be pleased to provide a replacement of this component. In order for me to arrange this, please confirm the order number and date of purchase.

    Thank you for your cooperation. I look forward to hearing from you.

    Read More

    Abcam Scientific Support

    Answered on Nov 20 2012

    Question

    a customer of ours has purchased your kit ab99995 (lot GR79069-3) but after dilution of buffer B, this buffer appears to be "opalescent"!.
    Is this normal? Does the customer can use it? Will the kit work?

    Please note that the customer works in a pharmaceutical industry so we would exclude a problet with the distilled water used to dilute the buffer.

    Kind regards

    Read More

    Abcam community

    Verified customer

    Asked on Sep 12 2012

    Answer

    Thank you for contacting us.

    This is very normal, the buffer contains proteins which gets precipitated at low temperature. Please keep the buffer at room temperature for few minutes and then vortex it. The white opaque residue will go away.

    The kit is absolutely fine so please use it without any hesitation.

    I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

    Use our products? Submit an Abreview. Earn rewards!
    https://www.abcam.com/abreviews

    Read More

    Abcam Scientific Support

    Answered on Sep 12 2012

    Question

    The two most recent CRP ELISA kits we ordered gave no signal at all with urine samples or the standards in the kit. An earlier kit from a different lot worked as expected.

    Read More

    Abcam community

    Verified customer

    Asked on Jul 26 2012

    Answer

    Thank you for confirming these details and for your cooperation. The details provided enable us to closely monitor the quality of our products.

    I am sorry this product did not perform as stated on the datasheet and for the inconvenience this has caused. As requested, I have issued a free of charge replacement.

    To check the status of the order please contact our Customer Service team and reference this number.

    Please note that this free of charge replacement vial is also covered by our Abpromise guarantee. Should you still be experiencing difficulties, or if you have any further questions, please do not hesitate to let us know.

    I wish you the best of luck with your research.

    Read More

    Abcam Scientific Support

    Answered on Jul 26 2012

    1-10 of 15 Abreviews or Q&A

    •  戻る
    • 1
    • 2
    • 次へ 

    Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
    For licensing inquiries, please contact partnerships@abcam.com

    技術情報や製品情報をメールで受け取る 登録
    製品・研究分野別
    • 癌
    • 循環器
    • 細胞生物学
    • 発生
    • エピジェネティクス&核内情報
    • 免疫学
    • メタボリズム
    • 感染症
    • ニューロサイエンス
    • シグナル伝達
    • ステムセル
    製品・タイプ別
    • 一次抗体
    • 二次抗体
    • バイオケミカルズ
    • アイソタイプ・コントロール
    • マルチカラー・セレクター
    • キット
    • ローディング・コントロール
    • ライゼート
    • ペプチド
    • タンパク質
    • スライド
    • タグ抗体・細胞マーカー
    • その他試薬
    サービス&サポート
    • サポート
    • よくあるお問い合わせ
    • プロトコール&トラブルシュート
    • ご購入に関して
    • お問い合わせフォーム
    • トレーニング
    • ターゲット別に見る
    アブカムについて
    • 企業ウェブサイト
    • 投資家の皆様へ
    • 企業情報
    • 採用情報
    • アブカムについて
    イベント
    • 展示会
    • カンファレンス
    International websites
    • abcam.com
    • abcam.cn

    Join with us

    • LinkedIn
    • facebook
    • Twitter
    • YouTube
    • Terms of sale
    • Website terms of use
    • Cookie policy
    • Privacy policy
    • Legal
    © 1998-2025 Abcam plc. All rights reserved.