GFP ELISA Kit, Chemiluminescent is a 55-min single-wash Simplestep IgniteTM ELISA for the rapid quantification of GFP with higher sensitivity and broader measuring range.

- Single 30 min incubation and single -wash step for results in less than an hour
- Chemiluminescent detection allows a broad dynamic range :4.9 - 10800 pg/mL with a sensitivity of 0.962 pg/mL
- Patent Pending

別名を表示する

Green fluorescent protein, GFP

5 Images
Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)
  • sELISA

Lab

Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)

SimpleStep ELISA® Ignite technology allows the formation of the antibody-antigen complex in one single step, reducing assay time to 55 minutes. Add samples or standards and antibody mix to wells all at once, incubate, wash, and add your final substrate. See protocol for a detailed step-by-step guide.

Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)
  • sELISA

Lab

Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)

Dynamic range comparison between the Chemiluminescent GFP SimpleStep ELISA and colorimetric GFP SimpleStep ELISA (ab171581).

Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)
  • sELISA

Lab

Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)

Titration of GFP spiked 143B cell lysate within the working range of the assay. Background subtracted data from triplicate measurements are plotted.

Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)
  • sELISA

Lab

Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)

This kit recognizes both GFP and enhanced GFP (eGFP) in cell and tissue extracts. No reactivity with mCherry, RFP, or YFP was observed.

Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)
  • sELISA

Lab

Sandwich ELISA - GFP ELISA Kit, Chemiluminescent (AB325363)

Standard curve comparison between the Chemiluminescent GFP SimpleStep ELISA and colorimetric GFP SimpleStep ELISA (ab171581) in 1X Cell Extraction Buffer PTR. Background-subtracted data values (mean +/- SD) are graphed.

Key facts

検出方法

Luminescent

サンプルタイプ

Cell Extract, Tissue Extracts

アッセイタイプ

Sandwich (quantitative)

検出感度

= 0.962 pg/mL

検出範囲

4.9 - 10800 pg/mL

アッセイ時間

55m

アッセイプラットフォーム

Pre-coated microplate (12 x 8 well strips)

Reactivity data

{ "title": "Reactivity Data", "filters": { "stats": ["", "Reactivity", "Dilution Info", "Notes"] }, "values": { "sELISA": { "reactivity":"TESTED_AND_REACTS", "dilution-info":"", "notes":"<p></p>" } } }

製品の詳細

GFP ELISA Kit, Chemiluminescent (ab325363) is a rapid single-wash sandwich 55-min ELISA to measure GFP in Cell Extract, Tissue Extract with a sensitivity of 0.962 pg/ml.

How the assay works

GFP ELISA Kit, Chemiluminescent (ab325363) SimpleStep ELISA®  employs capture antibodies conjugated to an affinity tag that is recognized by the monoclonal antibody used to coat our SimpleStep ELISA® plates. This approach to sandwich ELISA allows the formation of the antibody-analyte sandwich complex in a single step during a 30 min only incubation, significantly reducing assay time.  By utilizing a chemiluminscent detection method this improves the sensitivity and dynamic range when compared to traditional colormetric ELISAs.

Assay Specificity

Our SimpleStep ELISA® kits use recombinant monoclonal antibodies rigorously validated to ensure the highest level of consistency and reproducibility, improved sensitivity and specificity and ease of scalability and security of supply.

Please refer to our protocol booklet for more details.

GFP (ab325363) protocol summary

1. Mix : add samples / standards to the wells together with the capture and detector antibody cocktail. Incubate 30 min at room temperature

2. Wash

3. Add prepared ChemiHRP development solution - incubate for 2 min

4. Read the results on a plate reader capable of luminescence detection

REACH authorisation
Abcam has not and does not intend to apply for the REACH Authorisation of customers' uses of products that contain European Authorisation list (Annex XIV) substances.
It is the responsibility of our customers to check the necessity of application of REACH Authorisation, and any other relevant authorisations, for their intended uses.

精度

[ { "reproducibilityType": "Intra", "sample": "Extract", "replicates": 9, "mean": null, "standardDeviation": null, "coefficientOfVariability": "3.1" }, { "reproducibilityType": "Inter", "sample": "Extract", "replicates": 3, "mean": null, "standardDeviation": null, "coefficientOfVariability": "8.2" } ]

回収率

[ { "sample": "Cell culture media", "range": "101 - 103 %", "average": "= 102" }, { "sample": "Serum", "range": "96 - 98 %", "average": "= 97" } ]

製品内容

{ "values": { "1x96Tests": { "sellingSize": "1 x 96 Tests", "publicAssetCode":"ab325363-1x96Tests", "assetComponentDetails": [ { "size":"1 x 3 mL", "name":"ChemiHRP Reagent A", "number":"AB325363-CMP08", "productcode":"" }, { "size":"1 x 1 Unit", "name":"SimpleStep Pre-Coated Black 96-Well Microplate", "number":"AB325363-CMP10", "productcode":"" }, { "size":"1 x 3 mL", "name":"ChemiHRP Reagent B", "number":"AB325363-CMP09", "productcode":"" }, { "size":"1 x 600 µL", "name":"10X GFP Capture Antibody", "number":"AB325363-CMP01", "productcode":"" }, { "size":"1 x 6 mL", "name":"4X Antibody Diluent EB", "number":"AB325363-CMP04", "productcode":"" }, { "size":"1 x 20 mL", "name":"10X Wash Buffer PT (ab206977)", "number":"AB325363-CMP07", "productcode":"" }, { "size":"1 x 600 µL", "name":"10X GFP Detector Antibody", "number":"AB325363-CMP02", "productcode":"" }, { "size":"1 x 1 Unit", "name":"Plate Seal", "number":"AB325363-CMP11", "productcode":"" }, { "size":"1 x 1 mL", "name":"50X Cell Extraction Enhancer Solution (ab193971)", "number":"AB325363-CMP06", "productcode":"" }, { "size":"1 x 10 mL", "name":"5X Cell Extraction Buffer PTR (ab193970)", "number":"AB325363-CMP05", "productcode":"" }, { "size":"2 x 1 Vial", "name":"GFP Lyophilized Recombinant Protein", "number":"AB325363-CMP03", "productcode":"" } ] } } }

出荷温度及び保存条件

出荷温度
Blue Ice
短期保存温度
+4°C
長期保存温度
+4°C
保管に関する情報
+4°C

製品プロトコール

ターゲットの情報

Energy-transfer acceptor. Its role is to transduce the blue chemiluminescence of the protein aequorin into green fluorescent light by energy transfer. Fluoresces in vivo upon receiving energy from the Ca(2+)-activated photoprotein aequorin.
See full target information GFP
websiteProtocolBooklet
en

Abcam product promise

当社は、高品質な試薬を通じてお客様の研究を力強くサポートすることをお約束いたします。ご使用いただく各段階で、常にお客様をサポートできる体制を整えております。万が一、製品が期待通りに機能しない場合は、「Abcam Product Promise」による当社保証制度に基づき、安心してご利用いただけます。
保証に関する詳細については利用規約をご確認ください。

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com