JavaScript is disabled in your browser. Please enable JavaScript to view this website.
AB269893

Latex Conjugation Kit - 400nm Red

Latex Conjugation Kit - 400nm Red

Be the first to review this product! Submit a review

|

(5 Publications)

Latex Conjugation Kit - 400nm Red (ab269893) offers several standout features:

- Rapid Conjugation: achieve 400 nm red latex nanoparticle labeling in under 2 hours with less than 10 minutes of hands-on time.
- Requires less antibody than traditional passive and covalent latex conjugation.
- Latex nanoparticle particles are resistant to aggregation.
5 Images
Functional Studies - Latex Conjugation Kit - 400nm Red (AB269893)
  • FuncS

Supplier Data

Functional Studies - Latex Conjugation Kit - 400nm Red (AB269893)

Lateral Flow Assay of our specially treated latex beads conjugated to a monoclonal anti-CRP antibody (mAb1) titrated against CRP. 2ng/mL CRP can easily be detected.

Functional Studies - Latex Conjugation Kit - 400nm Red (AB269893)
  • FuncS

Supplier Data

Functional Studies - Latex Conjugation Kit - 400nm Red (AB269893)

Lateral Flow Assay of our specially treated latex conjugated to the monoclonal anti-CRP antibody (mAb2) titrated against CRP in buffer or CRP spiked CRP depleted serum (100 % serum). The latex behaves similarly in serum and buffer, and no aggregation or nonspecific binding is seen.

Conjugation - Latex Conjugation Kit - 400nm Red (AB269893)
  • Conjugation

PubMed

Conjugation - Latex Conjugation Kit - 400nm Red (AB269893)

Wieland, Felicia, et al used Latex Conjugation Kit - 400nm Red (ab269893) as part of examining polymeric materials. They used the kit to conjugate Latex to mouse IgG antibodies for use in plasma treatment of surfaces.
Photo of an (a) untreated and (b) a plasma activated PMMA foil after the linker-free immobilization of 400 nm bead labelled antibodies. SEM images of a single immobilization area with two different magnifications : (c) 50,000× and (d) 20,000×.

Image from Wieland et al., Polymers (Basel), 12(1):104; doi: 10.3390/polym12010104. Reproduced under the Creative Commons license https://creativecommons.org/licenses/by/4.0/

Lateral flow assay - Latex Conjugation Kit - 400nm Red (AB269893)
  • LFA

PubMed

Lateral flow assay - Latex Conjugation Kit - 400nm Red (AB269893)

Kim, Jinsu, et al used Latex Conjugation Kit - 400nm Red (ab269893) as part of examining human malaria species with multiplex lateral flow immunoassay. They used the kit to conjugate Latex to anti-PfHRP2 antibodies for use in lateral flow assay.
Representative test strips of the two-colour LFA. Distinct colours were observed at the test lines, corresponding a type of antigens, such as a blue test lines for pLDH detection only, b mixture colour of test lines for simultaneous detection, and c red test lines for PfHRP2 detection only. The mixture colour at control lines indicated the red and blue latex particles migrated along the length of the strip

Image from Kim et al., Malar J., 18(1):313; doi: 10.1186/s12936-019-2957-x. Reproduced under the Creative Commons license https://creativecommons.org/licenses/by/4.0/

Lateral flow assay - Latex Conjugation Kit - 400nm Red (AB269893)
  • LFA

Unknown

Lateral flow assay - Latex Conjugation Kit - 400nm Red (AB269893)

Multiplexed Latex.

The three colours of latex each conjugated to a different antibody or protein, forming a line either by a direct binding event (red and black latex) or a sandwich assay binding event (blue latex). The three colours of latex demonstrate no aggregation or background staining.

Key facts

Reactivity data

{ "title": "Reactivity Data", "filters": { "stats": ["", "Reactivity", "Dilution Info", "Notes"] }, "values": { "Conjugation": { "reactivity":"TESTED_AND_REACTS", "dilution-info":"", "notes":"<p></p>" } } }

製品の詳細

Latex Conjugation Kit – 400nm Red (ab269893) allows antibodies or proteins to be conjugated to our high quality 400 nm latex nanoparticles quickly and easily. The latex nanoparticles are designed for ease of use and have much improved handling compared with traditional latex. This has been achieved by specially treating the nanoparticles. The conjugation is covalent, and requires less antibody than traditional passive and covalent latex conjugation.

The 400 nm red latex nanoparticles in this kit are freeze dried. The conjugation reaction is initiated simply by reconstituting the dry mixture with the antibody, which becomes attached (via lysine residues) to the specially treated surface.

It takes 30 seconds to set up the conjugation, the hands-on time for the conjugation procedure is about 3 minutes and the conjugate is ready to use within 35 minutes. The biomolecule is simply pipetted into a vial containing the latex nanoparticles, then a centrifugation allows a buffer exchange.

The resulting covalent conjugates can be easily resuspended without the need for harsh methods such as sonication or vortexing, unlike traditional conjugation procedures which are prone to aggregation. This is due to the properties of the surface treatment which makes the particles resistant to aggregation.

Additionally, unlike passive methods, the conjugation procedure has only a weak dependence on the isoelectric point of the antibody. Consequently, extensive trials at different pH values are not required; all antibodies can be conjugated at one of two pHs, both of which are supplied in this kit (Reaction Buffers A and B).

Benefits of Latex Conjugation Kit:

Only 30 seconds to set up the conjugation

Three minutes hands-on time for the conjugation procedure

Conjugate is ready to use within 35 minutes – The biomolecule is simply pipetted into a vial containing the latex nanoparticles, then a centrifugation allows a buffer exchange.

General notes:

This product is manufactured by Expedeon, an Abcam company. It was previously called 400nm Blue Latex Conjugation Kit. Expedeon product code 1002-0040 (4 reaction mini kit) is the same as the 4 x 4 μg size of this product, code 1002-0100 (10 reaction mini kit) is the same as the 10 x 4 μg size, and code 1002-0120 (1 reaction mini kit) is the same as the 1 x 40 μg size of this product.

Buffer requirements:

We would suggest that the antibody to be conjugated should be in 10 – 50 mM MES, HEPES or MOPS at pH 6 – 7 (with no other components e.g. salt or azide) before conjugation. For incompatible buffers and low antibody concentrations, use our rapid antibody purification and concentration kits for Nanoparticles. To learn more about incompatible buffers, please refer to the protocol booklet.

製品内容

{ "values": { "4x4g": { "sellingSize": "4 x 4 µg", "publicAssetCode":"ab269893-4x4ug", "assetComponentDetails": [ { "size":"1 x 1 mL", "name":"Reaction Buffer B (1X)", "number":"AB269893-CMP02" }, { "size":"1 x 1 mL", "name":"Resuspension Buffer", "number":"AB269893-CMP01" }, { "size":"4 x 4 µg", "name":"400 nm Red Latex vial (Lyophilized)", "number":"AB269893-CMP05" }, { "size":"1 x 1 mL", "name":"Reaction Buffer A (1X)", "number":"AB269893-CMP03" }, { "size":"1 x 1500 µL", "name":"Quencher (10X)", "number":"AB269893-CMP04" } ] }, "1x40g": { "sellingSize": "1 x 40 µg", "publicAssetCode":"ab269893-1x40ug", "assetComponentDetails": [ { "size":"1 x 1 mL", "name":"Resuspension Buffer", "number":"AB269893-CMP01" }, { "size":"1 x 1500 µL", "name":"Quencher (10X)", "number":"AB269893-CMP04" }, { "size":"1 x 40 µg", "name":"400 nm Red Latex vial (Lyophilized)", "number":"AB269893-CMP05" }, { "size":"1 x 1 mL", "name":"Reaction Buffer B (1X)", "number":"AB269893-CMP02" }, { "size":"1 x 1 mL", "name":"Reaction Buffer A (1X)", "number":"AB269893-CMP03" } ] }, "10x4g": { "sellingSize": "10 x 4 µg", "publicAssetCode":"ab269893-10x4ug", "assetComponentDetails": [ { "size":"10 x 4 µg", "name":"400 nm Red Latex vial (Lyophilized)", "number":"AB269893-CMP05", "productcode":"" }, { "size":"1 x 1 mL", "name":"Resuspension Buffer", "number":"AB269893-CMP01", "productcode":"" }, { "size":"1 x 1500 µL", "name":"Quencher (10X)", "number":"AB269893-CMP04", "productcode":"" }, { "size":"1 x 1 mL", "name":"Reaction Buffer B (1X)", "number":"AB269893-CMP02", "productcode":"" }, { "size":"1 x 1 mL", "name":"Reaction Buffer A (1X)", "number":"AB269893-CMP03", "productcode":"" } ] } } }

出荷温度及び保存条件

出荷温度
Ambient - Cannot Ship with Ice
短期保存温度
-20°C
長期保存温度
-20°C
保管に関する情報
-20°C

製品プロトコール

ターゲットの情報

文献 (5)

Recent publications for all applications. Explore the full list and refine your search

Cancers 16: PubMed38473417

2024

Identification of GB3 as a Novel Biomarker of Tumor-Derived Vasculature in Neuroblastoma Using a Stiffness-Based Model.

Applications

Unspecified application

Species

Unspecified reactive species

Aranzazu Villasante,Josep Corominas,Clara Alcon,Andrea Garcia-Lizarribar,Jaume Mora,Monica Lopez-Fanarraga,Josep Samitier

Polymers 12: PubMed31947987

2020

Enhanced Protein Immobilization on Polymers-A Plasma Surface Activation Study.

Applications

Unspecified application

Species

Unspecified reactive species

Felicia Wieland,Richard Bruch,Michael Bergmann,Stefan Partel,Gerald A Urban,Can Dincer

Malaria journal 18:313 PubMed31533756

2019

A two-colour multiplexed lateral flow immunoassay system to differentially detect human malaria species on a single test line.

Applications

Unspecified application

Species

Unspecified reactive species

Jinsu Kim,Xiangkun Elvis Cao,Julia L Finkelstein,Washington B Cárdenas,David Erickson,Saurabh Mehta

Analytical chemistry 91:5415-5423 PubMed30896928

2019

Rapid Diagnostic Platform for Colorimetric Differential Detection of Dengue and Chikungunya Viral Infections.

Applications

Unspecified application

Species

Unspecified reactive species

Ruisheng Wang,Serge Y Ongagna-Yhombi,Zhengda Lu,Elizabeth Centeno-Tablante,Susannah Colt,Xiangkun Cao,Yue Ren,Washington B Cárdenas,Saurabh Mehta,David Erickson

Analytical chemistry 88:8359-63 PubMed27490379

2016

Two-Color Lateral Flow Assay for Multiplex Detection of Causative Agents Behind Acute Febrile Illnesses.

Applications

Unspecified application

Species

Unspecified reactive species

Seoho Lee,Saurabh Mehta,David Erickson
View all publications
websiteProtocolBooklet
en

Abcam product promise

当社は、高品質な試薬を通じてお客様の研究を力強くサポートすることをお約束いたします。ご使用いただく各段階で、常にお客様をサポートできる体制を整えております。万が一、製品が期待通りに機能しない場合は、「Abcam Product Promise」による当社保証制度に基づき、安心してご利用いただけます。
保証に関する詳細については利用規約をご確認ください。

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.