アブカムでは最適な動作のために Google Chrome など最新ブラウザでの閲覧を推奨します。

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
お問い合わせは電話 03-4571-1344 または メールでどうぞ

  • アカウント
  • ログアウト
ログイン または 新規登録

Welcome

ログイン または

すでにアカウントをお持ちですか?

新規登録
カート
クイック・オーダー
Abcam homepage

  • 研究用製品
    製品タイプ別
    一次抗体
    二次抗体
    イムノアッセイキット・試薬
    細胞・組織イメージング
    細胞・バイオケミカルアッセイ
    製品タイプ別
    タンパク質・ペプチド
    プロテオミクス
    アゴニスト・アクチベータ-・アンタゴニスト・インヒビター
    細胞株・ライゼート
    マルチプレックス・アッセイ
    研究分野別
    癌
    循環器系
    細胞生物学
    エピジェネティクス
    メタボリズム
    発生生物学
    研究分野別
    免疫学
    微生物学
    脳神経科学
    シグナル伝達
    ステムセル
  • カスタム製品 & パートナーシップ
    カスタム製品 & パートナーシップ

    診断や治療プログラムを加速するための、カスタム製品および商業化に向けたパートナーシップ

    カスタム製品

    私たちとパートナーになる

  • サポート
    サポートハブ

    研究のためのサポートとアドバイス

    サポートハブを表示

    プロトコール

    実験のステップごとの詳細

    プロトコールを表示

  • イベント
    • イベント・カレンダー
    • 癌
    • 循環器
    • エピジェネティクス&核内情報
    • 免疫学
    • ニューロサイエンス
    • ステムセル
    • 展示会
    • ウェビナー
    最新のイベント情報

    世界中でアブカムが主催する研究会やセミナーの日程、内容、演者など

    イベント・カレンダー

  • パスウェイ
    細胞シグナル伝達パスウェイ

    すべてのパスウェイを見る

    インタラクティブ・パスウェイを見る

  1. Link

    products/assay-kits/nitric-oxide-assay-kit-colorimetric-ab65328.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Kits/ Lysates/ Other Kits Cell Signaling Kits Nitric Oxide assay kits
Share by email

Nitric Oxide Assay Kit (Colorimetric) (ab65328)

  • Datasheet
  • SDS
  • Protocol Booklet
Reviews (2)Q&A (27)References (122)

Product price, shipping and contact information

Currently unavailable

申し訳ございませんが、現在表示できません。

こちらにお問い合わせいただくか、またはしばらく経ってから改めてお試しください

 

Loading size & price…

 

出荷および受注について

Shipping info

Promotion Information

Abpromise

保証された製品品質、優れたカスタマー・サポート。 詳細はこちら。

Functional Studies - Nitric Oxide Assay Kit (Colorimetric) (ab65328)
  • Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)
  • Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)
  • Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)
  • Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)

Key features and details

  • Assay type: Quantitative
  • Detection method: Colorimetric
  • Platform: Microplate reader
  • Assay time: 1 hr 30 min
  • Sample type: Cell Lysate, Other biological fluids, Plasma, Serum, Tissue Extracts, Urine
  • Sensitivity: 1 nmol/well

こちらの製品もご検討ください

ELISA
Product image
Human Fatty Acid Oxidation In-Cell ELISA Kit (ab118182)
Biochemical
Product image
DAF-2 DA, Fluorescent nitric oxide probe (ab145283)

関連製品

医薬用外劇物

製品の概要

  • 製品名

    Nitric Oxide Assay Kit (Colorimetric)
    Nitric oxide キット 製品一覧
  • 検出方法

    Colorimetric
  • サンプルの種類

    Urine, Serum, Plasma, Other biological fluids, Tissue Extracts, Cell Lysate
  • アッセイタイプ

    Quantitative
  • 検出感度

    1 nmol/well
  • 検出範囲

    1 nmol/well - 10 nmol/well
  • 全工程の試験時間

    1h 30m
  • 種交差性

    交差種: Mammals, Other species
  • 製品の概要

    Nitric Oxide Assay Kit (Colorimetric) ab65328 provides an accurate, convenient measure of total nitrate/nitrite in a simple two-step process.


    In the nitric oxide assay protocol:
    - the first step converts nitrate to nitrite by using nitrate reductase
    - the second step uses Griess Reagent to convert nitrite to a deep purple azo compound.
    The amount of the azochromophore accurately reflects nitric oxide amount in samples.


    Nitric oxide assay protocol summary:
    - add samples and standards to wells
    - add nitrate reductase and enzyme cofactor and incubate for 1 hr at room temp to convert nitrate to nitrite
    - add enhancer and incubate for 10 min at room temp
    - add Griess Reagent R1 and Griess Reagent R2
    - analyze with microplate reader

  • 特記事項

    This product is manufactured by BioVision, an Abcam company and was previously called K262 Nitric Oxide Colorimetric Assay Kit. K262-200 is the same size as the 2 96 tests size of ab65328.

    If you are interested in a fluorometric detection kit, please check Nitric Oxide Assay Kit (Fluorometric) (ab65327).

    For an assay kit to detect nitrite alone see Griess Reagent Kit ab234044.

    Nitric oxide (NO) plays an important role in neurotransmission, vascular regulation, immune response and apoptosis. NO is rapidly oxidized to nitrite and nitrate which are used to quantitate NO production.

    The Safety Datasheet for this product has been updated for certain countries. Please check the current version in the SDS download section.

  • 試験プラットフォーム

    Microplate reader

製品の特性

  • 保存方法

    Store at -20°C. Please refer to protocols.
  • 内容 2 x 96 tests
    Assay Buffer XVII 1 x 30ml
    Enhancer II 1 vial
    Enzyme Cofactor 1 vial
    Griess Reagent I   1 x 10ml
    Griess Reagent II 1 x 10ml
    96-Well Clear Plate 2 units
    Nitrate Reductase I 1 vial
    Nitrate Standard 1 vial
    Nitrite Standard 1 vial
    Microplate Sealing Film 2 units
  • 研究分野

    • Kits/ Lysates/ Other
    • Kits
    • Cell Signaling Kits
    • Nitric Oxide assay kits
    • Kits/ Lysates/ Other
    • Kits
    • Cell Metabolism Kits
    • Oxidative Stress Assay Kits
    • Oxidative Stress
  • 関連性

    Nitric oxide (NO) is a key vertebrate biological messenger, playing an important role in neurotransmission, vascular regulation, immune responses and apoptosis. NO , also known as "endothelium-derived relaxing factor" or "EDRF", is synthesized from L-arginine, oxygen and NADPH by various NO synthases. Most of the NO in the cell is oxidized to nitrite (NO2-) and nitrate (NO3-), and therefore the concentrations of these anions are generally as a quantitative measure of NO production.

関連製品

  • Related Products

    • SNAP, NO donor (ab120014)
    • N omega-Nitro-L-arginine methyl ester hydrochloride (L-NAME), NOS inhibitor (ab120136)
    • NG-Monomethyl-L-arginine, monoacetate salt (L-NMMA), NOS inhibitor (ab120137)
    • 1400W, iNOS inhibitor (ab120165)
    • Apocynin, NADPH-oxidase inhibitor (ab120615)
    • 10kD Spin Column (ab93349)

画像

  • Functional Studies - Nitric Oxide Assay Kit (Colorimetric) (ab65328)
    Functional Studies - Nitric Oxide Assay Kit (Colorimetric) (ab65328)Nam, Eunryel et al., Scientific reports vol. 8,1 7312., Fig 4 , doi:10.1038/s41598-018-25786-x
    Blood NOx concentration measured with ab65328. Blood NOx concentration after application of the NE with NO. The level of blood NOx concentration increased 3-fold after the application of the NE with NO compared with control group.
  • Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)
    Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)

    Nitrite and nitrate measured in cell lysates showing quantity (micromol) per 106 cells

  • Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)
    Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)

    Nitrite and nitrate measured in biologicals showing concentration (micromolar)

  • Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)
    Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)

    Standard curve (colorimetric) : mean of duplicates (+/-SD) with background readings subtracted

  • Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)
    Functional Studies - Nitric Oxide Colorimetric Assay Kit (ab65328)

    Standard curve (Colorimetric) : mean of duplicates (+/-SD) with background readings subtracted

プロトコール

  • Protocol Booklet

Click here to view the general protocols

データシートおよび資料

  • SDS download

  • Datasheet download

    Download

参考文献 (122)

ab65328 を使用した論文を発表された方は、こちらまでお知らせください。データシートに掲載させていただきます。

ab65328 は 122 報の論文で使用されています。

  • Verma N  et al. Aβ efflux impairment and inflammation linked to cerebrovascular accumulation of amyloid-forming amylin secreted from pancreas. Commun Biol 6:2 (2023). PubMed: 36596993
  • Rahmani AH  et al. Quercetin, a Plant Flavonol Attenuates Diabetic Complications, Renal Tissue Damage, Renal Oxidative Stress and Inflammation in Streptozotocin-Induced Diabetic Rats. Metabolites 13:N/A (2023). PubMed: 36677055
  • Feenstra L  et al. Calciprotein Particles Induce Endothelial Dysfunction by Impairing Endothelial Nitric Oxide Metabolism. Arterioscler Thromb Vasc Biol 43:443-455 (2023). PubMed: 36727521
  • Bahgat DM  et al. Essential Oil of Cestrum diurnum L.: GC/MS Analysis, in Vitro and in Silico Anti-HCoV-229E Effects and Inhibitory Activity against LPS-Induced Inflammation. Chem Biodivers 20:e202201045 (2023). PubMed: 36811152
  • Younis NS & Mohamed ME Anethole Pretreatment Modulates Cerebral Ischemia/Reperfusion: The Role of JNK, p38, MMP-2 and MMP-9 Pathways. Pharmaceuticals (Basel) 16:N/A (2023). PubMed: 36986541
View all Publications for this product

レビューと Q&A

Show All レビュー Q&A
レビューを送る 質問を送る

1-10 of 29 Abreviews or Q&A

Rat Plasma

Good Below average 2/5 (Ease of Use)
Abreviews
Abreviews
abreview image
Overall the test worked well for us. All of the required information was included, but the way that the steps were structured was awkward at times. This made the protocol difficult to follow.
Specifically, the section describing how to deproteinize your sample (step 11.4.4 in protocol booklet). An online protocol is also available from abcam, and was a little more clear (https://www.abcam.com/protocols/deproteinization-protocol). It would be nice if these protocols were updated to be more clear and uniform across abcam.
The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

Abcam user community

Verified customer

投稿 Feb 27 2018

Use of nitric oxide colormetric assay on avian plasma samples

Average Good 4/5 (Ease of Use)
Abreviews
Abreviews
I used this kit to measure nitric oxide (nitrate and nitrite combined) in the plasma of adult male red-winged blackbirds (Agelaius phoeniceus) housed in an outdoor aviary. Preliminary data suggests that the assay requires a minimum of 15uL of plasma per well (ie, 30uL plasma to run in duplicate) to produce repeatable results. Thus far, we have found birds to have levels of NOx between 14-250 uM. It appears that birds with an active infection could have elevated NOx.
Preliminary data also suggests that error can be easily introduced when ready-ing the samples for the assay by deproteinating plasma with PCA. I suspect that this is particularly problematic for samples with absorbance reading less than 0.2, but we need more evidence to be certain.
I did notice that the instructions on the web site were not the same as in the booklet sent. In the booklet I received, the instructions said to use the plate reader after adding the second Griess reagent with no wait time listed. On the online book an incubation time was listed (10 min). There were also inconsistencies in the the list of reagents provided and what was actually provided (We got plates, which is great!). The plates were labeled with a store in -20C, even though they're just plastic plates that isn't necessary.
Technical support was very helpful in answering questions quickly whenever I called - was really happy with the support.
The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

Abcam user community

Verified customer

投稿 Feb 01 2016

Question

Inquiry: My assay buffer got spilled what can I use to replace it? Is PBS ok?

Read More

Abcam community

Verified customer

Asked on May 03 2013

Answer



I am happy to confirm that extra assay buffer can now be purchased using the following product number:

ab171368

https://www.abcam.com/Nitric-Oxide-Assay-Buffer-ab171368.html (or use the following: https://www.abcam.com/Nitric-Oxide-Assay-Buffer-ab171368.html).

PBS is not a suitable replacement for the assay buffer.

Read More

Abcam Scientific Support

Answered on May 03 2013

Question

appel- est-ce que les échantillons (surnagéants de culture)peuvent être congélées avant l'experience?

Read More

Abcam community

Verified customer

Asked on Aug 31 2012

Answer

Merci pour votre patience.

Le laboratoire vient de me confirmer que le NO est stable et que les échantillons de surnagéant aussi peuvent donc être conservées en aliquots à-20°C ou -80°C.

J'espère que cet information vous est utile. N'hésitez pas à nous recontacter si vous avez des autres questions.

Read More

Abcam Scientific Support

Answered on Aug 31 2012

Question

which one of these 2 kits is more sensitive?

Read More

Abcam community

Verified customer

Asked on Sep 20 2011

Answer

Thank you for contacting us. The Fluorometric assay kit ab65327 is much more sensitive (about 10x) than kit ab65328 (colorimetric assay kit). For ab65328 (colorimetric): The absorbance of samples should be in the linear range of the standard curve (0-10 nmol/well). The detection limit of the assay is approximately 0.1 nmol nitrite/well, or 1 µM. For ab65327 (fluorometric): The fluorescence of samples should be in the linear range of the standard curve (0-1000 pmol/well). A 1000 pmol = 1 nmol. The detection limit of the assay is approximately 10 pmol nitrite/well, or 0.1 µM. I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

Read More

Abcam Scientific Support

Answered on Sep 20 2011

Question

Can this kit be used with MEM tissue culture medium that contains phenol red?

Read More

Abcam community

Verified customer

Asked on Aug 25 2009

Answer

Thank you for your enquiry. This kit will be compatible with MEM with phenol red. Media that contain phenol red as a pH indicator do not interfere with the Griess reaction as the indicator is typically yellow colored under the conditions of the Griess reaction. You want to be sure to avoid media that contain nitrates, such as RPMI which contains calcium nitrate. MEM does not. Also, NO synthetase enzymes utilize high concentrations (0.5-1 mM) of NADPH which may inhibit the Griess color reaction slightly. If your know that your samples contain NO synthetase, you will want to take this into consideration when interpreting your data. I hope this information helps. Please do not hesitate to contact us if you need any more advice or information.

Read More

Abcam Scientific Support

Answered on Aug 25 2009

Question

after you add the enhancer and incubate for 10 mins you then add grey as rehang r1 and then r2. Do you wait and incubate after adding the greiss regent r1? And how long after addition of the regent r2 do you need to wait before you can you measure outputs?

Read More

Abcam community

Verified customer

Asked on Jun 29 2016

Answer

fter adding Griess Reagent R2 in standard and unknown leave it for 10 minutes at room temperature. The color developed will be stable for an hour.   

Read More

Padamjeet Singh

Abcam Scientific Support

Answered on Jun 29 2016

Question

Is heparin lithium is OK for treating plasma samples used with these 2 kits?

Read More

Abcam community

Verified customer

Asked on Sep 23 2014

Answer

Yes, heparin should be fine to use with ab65328 and ab118970.

Read More

Jeremy Kasanov

Abcam Scientific Support

Answered on Sep 23 2014

Question

Our lysis buffer has salts, triton X-100 and protease inhibitors. Do you have any information about which components would interfere with the NO analysis

Read More

Abcam community

Verified customer

Asked on Aug 26 2013

Answer



Standard amounts of salts, Triton and protease inhibitors should be alright. We have not tested this kit’s function using high salt/detergent but theoretically small amounts of these should not interfere with the assay.

Read More

XXXXXX XXXXXX

Abcam Scientific Support

Answered on Aug 26 2013

Question

I was wondering if you could let me know if the product above includes a step to remove proteins? Or if it needs one?

Read More

Abcam community

Verified customer

Asked on Mar 08 2013

Answer


This kit does not include a step to remove proteins. Depending on your sample type, it is however recommended to use 10kD spin columns (ab93349) to deproteinate your samples.

For example, it is recommended for serum samples since there are proteins in the serum which can interfere with the nitrite level but this may not be necessary for cell lysates.

Read More

Abcam Scientific Support

Answered on Mar 08 2013

1-10 of 29 Abreviews or Q&A

  •  戻る
  • 1
  • 2
  • 3
  • 次へ 

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

技術情報や製品情報をメールで受け取る 登録
製品・研究分野別
  • 癌
  • 循環器
  • 細胞生物学
  • 発生
  • エピジェネティクス&核内情報
  • 免疫学
  • メタボリズム
  • 感染症
  • ニューロサイエンス
  • シグナル伝達
  • ステムセル
製品・タイプ別
  • 一次抗体
  • 二次抗体
  • バイオケミカルズ
  • アイソタイプ・コントロール
  • マルチカラー・セレクター
  • キット
  • ローディング・コントロール
  • ライゼート
  • ペプチド
  • タンパク質
  • スライド
  • タグ抗体・細胞マーカー
  • その他試薬
サービス&サポート
  • サポート
  • よくあるお問い合わせ
  • プロトコール&トラブルシュート
  • ご購入に関して
  • お問い合わせフォーム
  • トレーニング
  • ターゲット別に見る
アブカムについて
  • 企業ウェブサイト
  • 投資家の皆様へ
  • 企業情報
  • 採用情報
  • アブカムについて
イベント
  • 展示会
  • カンファレンス
International websites
  • abcam.com
  • abcam.cn

Join with us

  • LinkedIn
  • facebook
  • Twitter
  • YouTube
  • Terms of sale
  • Website terms of use
  • Cookie policy
  • Privacy policy
  • Legal
© 1998-2025 Abcam plc. All rights reserved.