アブカムでは最適な動作のために Google Chrome など最新ブラウザでの閲覧を推奨します。

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
お問い合わせは電話 03-4571-1344 または メールでどうぞ

  • アカウント
  • ログアウト
ログイン または 新規登録

Welcome

ログイン または

すでにアカウントをお持ちですか?

新規登録
カート
クイック・オーダー
Abcam homepage

  • 研究用製品
    製品タイプ別
    一次抗体
    二次抗体
    イムノアッセイキット・試薬
    細胞・組織イメージング
    細胞・バイオケミカルアッセイ
    製品タイプ別
    タンパク質・ペプチド
    プロテオミクス
    アゴニスト・アクチベータ-・アンタゴニスト・インヒビター
    細胞株・ライゼート
    マルチプレックス・アッセイ
    研究分野別
    癌
    循環器系
    細胞生物学
    エピジェネティクス
    メタボリズム
    発生生物学
    研究分野別
    免疫学
    微生物学
    脳神経科学
    シグナル伝達
    ステムセル
  • カスタム製品 & パートナーシップ
    カスタム製品 & パートナーシップ

    診断や治療プログラムを加速するための、カスタム製品および商業化に向けたパートナーシップ

    カスタム製品

    私たちとパートナーになる

  • サポート
    サポートハブ

    研究のためのサポートとアドバイス

    サポートハブを表示

    プロトコール

    実験のステップごとの詳細

    プロトコールを表示

  • イベント
    • イベント・カレンダー
    • 癌
    • 循環器
    • エピジェネティクス&核内情報
    • 免疫学
    • ニューロサイエンス
    • ステムセル
    • 展示会
    • ウェビナー
    最新のイベント情報

    世界中でアブカムが主催する研究会やセミナーの日程、内容、演者など

    イベント・カレンダー

  • パスウェイ
    細胞シグナル伝達パスウェイ

    すべてのパスウェイを見る

    インタラクティブ・パスウェイを見る

  1. Link

    products/assay-kits/iron-assay-kit-colorimetric-ab83366.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Cardiovascular Blood Serum Proteins
Share by email

Iron Assay Kit (Colorimetric) (ab83366)

  • Datasheet
  • SDS
  • Protocol Booklet
Reviews (3)Q&A (19)References (367)

Product price, shipping and contact information

Currently unavailable

申し訳ございませんが、現在表示できません。

こちらにお問い合わせいただくか、またはしばらく経ってから改めてお試しください

 

Loading size & price…

 

出荷および受注について

Shipping info

Promotion Information

Abpromise

保証された製品品質、優れたカスタマー・サポート。 詳細はこちら。

Functional studies - ab83366
  • Functional Studies - Iron Assay Kit (ab83366)
  • Functional Studies - Iron Assay Kit (ab83366)
  • Functional Studies - Iron Assay Kit (ab83366)
  • Functional Studies - Iron Assay Kit (ab83366)

Key features and details

  • Assay type: Quantitative
  • Detection method: Colorimetric
  • Platform: Microplate reader
  • Assay time: 1 hr 30 min
  • Sample type: Hep Plasma, Other biological fluids, Serum, Urine
  • Sensitivity: 8 µM

こちらの製品もご検討ください

ELISA
Product image
Mouse Ferritin ELISA Kit (FTL) (ab157713)
アッセイ
Product image
Lipid Peroxidation (MDA) Assay Kit (Colorimetric) (ab233471)
キット
Product image
Hemoglobin Assay Kit (Colorimetric) (ab234046)

関連製品

製品の概要

  • 製品名

    Iron Assay Kit (Colorimetric)
    Iron キット 製品一覧
  • 検出方法

    Colorimetric
  • サンプルの種類

    Urine, Serum, Other biological fluids, Hep Plasma
  • アッセイタイプ

    Quantitative
  • 検出感度

    > 8 µM
  • 検出範囲

    8 µM - 400 µM
  • 全工程の試験時間

    1h 30m
  • 製品の概要

    Iron Assay Kit ab83366 provides a simple convenient means of measuring ferrous (Fe2+) and/or ferric (Fe3+) iron in biological samples.


    How the assay works
    This ferrozine assay kit / iron assay kit uses an improved variant of the ferrozine molecule (ferene) which has been shown to give more accurate results for biological iron levels; that are closer to the results seen with mass spectrometry.


    In a ferrozine assay, free ferrous iron (Fe2+) reacts with the ferrozine molecule (in this case the ferene molecule) to produce a stable colored complex with absorbance that can be measured with a colorimetric plate reader. The ferene iron probe used in this assay kit has absorbance at 593 nm when complexed with ferrous iron (Fe2+).


    In Iron Assay Kit ab83366, in addition to the ferene iron probe and iron standard, an acidic assay buffer, with pH less than 5.5, is provided to release iron from iron carrier proteins. A reducing agent is also provided to convert ferric iron (Fe3+) to form Fe2+.


    Ferrous iron (Fe2+) can be measured alone, or by addition of the reducing agent the level of total iron (Fe2+ and Fe3+) can be measured. The level of ferric iron (Fe3+) is calculated by subtracting ferrous iron from total iron.


    A specific chelate chemical is included in the buffer to block copper ion (Cu2+) interference.


    The kit measures iron in the linear range of 0.4 to 10 nmol or 8 μM to 200 μM.


    Iron assay protocol summary


    - Add samples and standards to wells
    - For Fe2+ assay add assay buffer only, for total iron (Fe2+ and Fe3+) add iron reducer
    - Incubate for 30 min at 37°C
    - Add Iron Probe and incubate for 60 min at 37°C
    - Analyze with microplate reader


    Getting the best performance from ab83366
    This assay is not suitable for use with samples containing EDTA or citrate.


    Related and recommended products
    Iron Assay Kit ab83366 is often used in combination with Lipid Peroxidation (MDA) Assay Kit ab118970 and GSH/ GSSG Assay Kit ab239709 in the study of ferroptosis.


    To measure total iron binding capacity and iron levels in serum, we recommend Total Iron-Binding Capacity (TIBC) and Serum Iron Assay Kit ab239715.


    For iron staining in tissues, we recommend Iron Stain Kit (Prussian Blue Stain) ab150674.


    Other notes
    This product is manufactured by BioVision, an Abcam company and was previously called K390 Iron Colorimetric Assay Kit. K390-100 is the same size as the 100 test size of ab83366.

  • 特記事項

    The Safety Datasheet for this product has been updated for certain countries. Please check the current version in the SDS download section.

  • 試験プラットフォーム

    Microplate reader

製品の特性

  • 保存方法

    Store at -20°C. Please refer to protocols.
  • 内容 100 tests 2000 tests
    Iron Assay Buffer 1 x 25ml 20 x 25ml
    Iron Probe 1 x 12ml 20 x 12ml
    Iron Reducer 1 x 700µl 20 x 700µl
    Iron Standard I 1 x 100µl 20 x 100µl
  • 研究分野

    • Cardiovascular
    • Blood
    • Serum Proteins
    • Signal Transduction
    • Metabolism
    • Vitamins / Minerals
    • Kits/ Lysates/ Other
    • Kits
    • Cell Metabolism Kits
    • Other Metabolism Assay
    • Kits/ Lysates/ Other
    • Kits
    • Cell Signaling Kits
    • Ions and Metal Assay Kits
  • 関連性

    Iron is essential to nearly all known organisms. It is generally stored in the centre of metalloproteins, in the heme complex, and in oxygen carrier proteins. Inorganic iron also contributes to redox reactions in the iron-sulfur clusters of many enzymes, such as nitrogenase and hydrogenase.
  • 別名

    • Fe
    • Fe++
    • Fe+++

画像

  • Functional studies - ab83366
    Functional studies - ab83366Leal SM Jr et al., PLoS Pathog 9(7), fig 2c. doi: 10.1371/journal.ppat.1003436. Reproduced under the Creative Commons license http://creativecommons.org/licenses/by/4.0/

    Leal SM Jr et al examined if iron availability regulates fungal growth in an infection as fungal infection intiates an iron sequestration response. Mice given Fe-dextran (Fe-Dex) and deferoxamine (Defox) shows a higher fungal mass (Fungal dsRed) compared to vehicle treated mice over 48 hours. Iron content was quantified in mouse serum using Iron assay kit (ab83366).

  • Functional Studies - Iron Assay Kit (ab83366)
    Functional Studies - Iron Assay Kit (ab83366)

    Iron measured in human urine showing concentration (micromolar)

  • Functional Studies - Iron Assay Kit (ab83366)
    Functional Studies - Iron Assay Kit (ab83366)

    Assay of soluble free iron from a soil sample (5 μL of 100 μL buffer into which 100 mg of soil had been stirred), 5 μL of FBS and 5 μL of a 100 μM sample of iron standard.

  • Functional Studies - Iron Assay Kit (ab83366)
    Functional Studies - Iron Assay Kit (ab83366)

    Example of iron standard curve using ab83366.

  • Functional Studies - Iron Assay Kit (ab83366)
    Functional Studies - Iron Assay Kit (ab83366)

    Assay of total iron(II + III) in off-the-clot human serum (50 µl of serum was added per well). Data are mean ± SEM from 2 independent replicates, performed in duplicate wells.

プロトコール

  • Protocol Booklet

Click here to view the general protocols

データシートおよび資料

  • SDS download

  • Datasheet download

    Download

参考文献 (367)

ab83366 を使用した論文を発表された方は、こちらまでお知らせください。データシートに掲載させていただきます。

ab83366 は 367 報の論文で使用されています。

  • Ma Y  et al. Echinacoside ameliorates doxorubicin‑induced cardiac injury by regulating GPX4 inhibition‑induced ferroptosis. Exp Ther Med 27:29 (2024). PubMed: 38125366
  • Hu Y  et al. Serine and arginine rich splicing factor 1‑regulated microtubule interacting and trafficking domain containing 1 affects colorectal cancer progression and ferroptosis. Exp Ther Med 27:45 (2024). PubMed: 38144919
  • Pang P  et al. Knockdown of fat mass and obesity alleviates the ferroptosis in Parkinson's disease through m6A-NRF2-dependent manner. Cell Biol Int 48:431-439 (2024). PubMed: 38180302
  • Xu X  et al. SENP1 inhibits ferroptosis and promotes head and neck squamous cell carcinoma by regulating ACSL4 protein stability via SUMO1. Oncol Rep 51:N/A (2024). PubMed: 38186303
  • Wang J  et al. POU6F1 promotes ferroptosis by increasing lncRNA-CASC2 transcription to regulate SOCS2/SLC7A11 signaling in gastric cancer. Cell Biol Toxicol 40:3 (2024). PubMed: 38267746
View all Publications for this product

レビューと Q&A

Show All レビュー Q&A
レビューを送る 質問を送る

1-10 of 22 Abreviews or Q&A

Using extract from murine colon feces for iron determination.

Excellent Excellent 5/5 (Ease of Use)
Abreviews
Abreviews
abreview image
I used pools of sera and colon poo extract to assess the utility of the kit for different samples. These samples were from Apodemus sylvaticus mice.
Sample preparation:
1. Sera was defrosted after storage at -80C. Centrifuged defrosted sera at 12000 rpm for 4mins.
2. Avoided disrupting the pellet and pipetted off equal volumes of sera into a clean Eppendorf to form a pool.
3. Colon poo was also defrosted from -80C. I weighed the sample and multiplied this mass by 3, and added this volume of proteinase inhibitor solution (PIS). For 0.2g of colon poo, a volume of 600ul PIS was added.
a. PIS was prepared by dissolving one tablet of Complete Mini Protease Inhibitor Cocktail Tablets (Roche, 11836153001) in 10ml 1x PBS.
4. Vortexed poo and PIS for 5 minutes. Stood for an hour at room temperature. Centrifuged at 12000rpm for 5 minutes. Pipetted equal volumes of supernatant into a clean Eppendorf to form the faecal extract pool.
5. Make a 1mM standard by diluting 2ul standard into 198ul Dh20.
6. Diluted samples and standards into wells with assay buffer.
Dilutions are listed.
a. Standard, in final volumes of 50ul and 100ul. 2nmol/well, 4nmol/well, 6nmol/well, 8nmol/well, 10nmol/well.
b. Sera 50ul volume, 1:1, 2:5, 1:5, 1:50.
c. Sera 100ul volume 1:2, 1:5, 1:10, 1:100.
d. Fecal extract 50ul volume, 1:1, 2:5, 1:5, 1:50, 1:100.
e. Fecal extract 25ul volume 1:1, 1:2, 1:5, 1:10, 1:100.
7. Add 5ul iron reducer to 100ul samples and standards. Add 2.5ul to 50ul samples.
8. Add 100ul probe to 100ul wells and 50ul probe to 50ul wells.
9. Incubate for 1hr protected from light at 37 degrees C.
10. Read at 593nm.

Conclusions:
I was testing whether for a small volume of sample it is better to dilute the sample into a large volume or to have the sample at a higher concentration in a lower volume. Both volumes worked equally well here. The poo pool had lower readings than the serum pool but was still detectable. Serum volumes of 5-10ul or faecal extract volume of 20ul would be suitable for future use. I used the two standard curves of different volumes to calculate concentrations for each pool. I averaged readings across dilutions. The concentration of the pools was 87uM for faecal extract in 105uL total well volume or 89uM in 205uL well volume. Sera was 205uM in 105uL total well volume or 219uM in 200uL. Both protocols gave congruent readings.
The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

Abcam user community

Verified customer

投稿 Dec 20 2022

Iron assay Kit ab 83366

Excellent Excellent 5/5 (Ease of Use)
Abreviews
Abreviews
The product is working with satisfactory reading using Serum and tissue lysate. In the next step i am testing in rabbit CSF for Iron forms II and III.
I will update/ upload data sets once i complete CSF analysis.
The kit is working total iron assay for rabbit templates ( Serum and Lysate)
The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

Abcam user community

Verified customer

投稿 Feb 09 2022

Detection of iron levels in hair samples

Average Good 4/5 (Ease of Use)
Abreviews
Abreviews
We used the iron assay kit to evaluate whether iron can be detected in hair shaft samples. In this case, we used a hair sample from a Rhesus primate, since we had a sufficient amount to test. The hair sample was milled into a fine powder, homogenized with assay buffer (4x volume) and centrifuged as directed. We initially tested various small amounts of hair (ranging from 1.8 to 12.1mg), given that these samples are often only available in limited quantities. The resulting absorbance was very close to the base nm of the 0 standard, and translated to -0.043 to 0.034nmoles per 50μl sample. We had used two sets of standard concentrations: the set of standards recommended in the protocol (0-10nmol/well) and a 1:10 dilution of those standards (0-1nmol/well). Both standard curves had an R-value better than 0.98, and the diluted standard curve was used since it best encompassed the resulting nm.
We repeated the assay with a larger amount of hair (55.9mg). In the increased sample we were able to detect 0.14-0.23nmole per 50μl sample, which was closer to the stated range of the kit (0.4-20 nmole/50μl). This indicates that it is possible to detect iron in hair shaft sample using this kit. However, given the relatively large amount of sample needed, it is not an ideal method for limited sample sizes. The kit itself was very easy to use.
The reviewer received a reward from Abcam’s Loyalty Program in thanks for submitting this Abreview and for helping the scientific community make better-informed decisions.

DR. Erilynn Heinrichsen

Verified customer

投稿 Nov 05 2013

Question

Can I use this kit with plasma samples?

Read More

Abcam community

Verified customer

Asked on Nov 27 2014

Answer

Unfortunately, this kit is not suitable for use with plasma samples due to the presence of iron binding transferrin in plasma leading to inaccurate measurements of free iron.

Read More

Elisa Thomas

Abcam Scientific Support

Answered on Nov 27 2014

Question

My plate reader reads at 570 nm, but I see this kit requires 593 nm. Could you send me the emission spectra for the probe, so I can determine whether or not my platereader would be compatible?

Read More

Abcam community

Verified customer

Asked on Jun 04 2014

Answer

Since the specific probe is proprietary we do not have a spectrum to share, but in our experience reading at 570 nm should work and may simply reduce the sensitivity slightly.

The emission profile shows a sharp peak at 580-590 nm, can measure signal within 590 +/- 20 nm.

Read More

Kevin Hanson

Abcam Scientific Support

Answered on Jun 04 2014

Question

i want to measure ferrous and ferric acid separately, can I do that with this kit?

Read More

Abcam community

Verified customer

Asked on Feb 13 2013

Answer

Yes, you can definitely measure ferrous and ferric acid separately with this kit. Please follow the protocol for measuring the ferrous and the total iron in the samples. When you subtract the ferrous levels from the total level, you get the ferric levels in the samples.

Read More

Abcam Scientific Support

Answered on Feb 13 2013

Question

During sample prep we are seeing cloudiness form but not blue color when using mouse liver samples. Samples are homogenized in Assay buffer with dounce homogenizer and spun at 16,000 x g as recommended. We have used straight attempted dilution of the samples 1/10 & 1/100. The kit is new and has been stored correctly.

Read More

Abcam community

Verified customer

Asked on May 22 2013

Answer

This is a common problem seen in liver and serum samples. Lipoproteins in the sample are the main culprits behind this turbidity.
For this purpose, we would recommend that to add 5 µl/well of 1 M SDS (28.8% or 288 mg/ml of SDS) to all their sample wells after step 4.2. Incubate for 30 min at 25 °C as mentioned in the datasheet and then follow the protocol. This SDS will clear up the turbidity (by dissolving any lipoproteins in the samples).

Read More

Abcam Scientific Support

Answered on May 22 2013

Question

Can I use samples that have been prepared using RIPA buffer?

Read More

Abcam community

Verified customer

Asked on Aug 21 2012

Answer

We do not typically recommend using RIPA buffer with our kits since it contains SDS which can denature proteins but for this assay it could work. We have not tested with RIPA buffer. We recommend using the assay buffer that comes with the kit.

Read More

Abcam Scientific Support

Answered on Aug 21 2012

Question

Does the assay also measure heme bound iron? or just the so called free iron.

Read More

Abcam community

Verified customer

Asked on Feb 03 2011

Answer

I can confrim that the ab83366 Iron Assay Kit will measure the free ferrous and ferric forms of iron and not the iron complexed in Heme.

Read More

Abcam Scientific Support

Answered on Feb 03 2011

Question

I have a couple questions about this kit:
1. How are the reagents to be stored between uses?
2. Does the plate need to be covered during incubations?

Read More

Abcam community

Verified customer

Asked on Jun 13 2014

Answer

1. All components should be stored in aliquots according to individual use requirements at -20C to prevent freeze-thaw cycles.

2. The plate can be covered by a plate cover and aluminium foil to protect from light during incubation. The incubation is at RT and hence there is not much concern about evaporation at 25C.

Read More

Jeremy Kasanov

Abcam Scientific Support

Answered on Jun 13 2014

1-10 of 22 Abreviews or Q&A

  •  戻る
  • 1
  • 2
  • 3
  • 次へ 

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

技術情報や製品情報をメールで受け取る 登録
製品・研究分野別
  • 癌
  • 循環器
  • 細胞生物学
  • 発生
  • エピジェネティクス&核内情報
  • 免疫学
  • メタボリズム
  • 感染症
  • ニューロサイエンス
  • シグナル伝達
  • ステムセル
製品・タイプ別
  • 一次抗体
  • 二次抗体
  • バイオケミカルズ
  • アイソタイプ・コントロール
  • マルチカラー・セレクター
  • キット
  • ローディング・コントロール
  • ライゼート
  • ペプチド
  • タンパク質
  • スライド
  • タグ抗体・細胞マーカー
  • その他試薬
サービス&サポート
  • サポート
  • よくあるお問い合わせ
  • プロトコール&トラブルシュート
  • ご購入に関して
  • お問い合わせフォーム
  • トレーニング
  • ターゲット別に見る
アブカムについて
  • 企業ウェブサイト
  • 投資家の皆様へ
  • 企業情報
  • 採用情報
  • アブカムについて
イベント
  • 展示会
  • カンファレンス
International websites
  • abcam.com
  • abcam.cn

Join with us

  • LinkedIn
  • facebook
  • Twitter
  • YouTube
  • Terms of sale
  • Website terms of use
  • Cookie policy
  • Privacy policy
  • Legal
© 1998-2025 Abcam plc. All rights reserved.