Cellular Membrane Potential Assay Kit (Fluorometric - Red) (ab176765)
Key features and details
- Assay type: Cell-based (quantitative)
- Detection method: Fluorescent
- Platform: Microplate reader
- Sample type: Adherent cells, Suspension cells
製品の概要
-
製品名
Cellular Membrane Potential Assay Kit (Fluorometric - Red)
cellular membrane potential キット 製品一覧 -
検出方法
Fluorescent -
サンプルの種類
Adherent cells, Suspension cells -
アッセイタイプ
Cell-based (quantitative) -
種交差性
交差種: Mammals, Other species -
製品の概要
Abcam's Cellular Membrane Potential Assay Kit (Fluorometric - Red) (ab176765) is a homogeneous assay with fast read time. It uses a proprietary long wavelength membrane potential indicator to detect the membrane potential change that is caused by the opening and closing of the ion channels. The red fluorescence of the membrane potential indicator used in the kit has enhanced fluorescence upon entering cells and minimizes the interferences resulted from the screening compounds and/or cellular autofluorescence.
-
特記事項
Membrane potential is the difference in voltage between the interior and exterior of a cell. The membrane potential allows a cell to function as a battery, providing power to operate a variety of "molecular devices" embedded in the membrane. In electrically excitable cells such as neurons, membrane potential is used for transmitting signals between different parts of a cell. Opening or closing of ion channels at one point in the membrane produces a local change in the membrane potential, which causes electric current to flow rapidly to other points in the membrane. Ion channels have been identified as important drug discovery targets.
-
試験プラットフォーム
Microplate reader
製品の特性
-
保存方法
Store at -20°C. Please refer to protocols. -
内容 1 x 96 tests 10 x 96 tests 100 x 96 tests 10X MP Sensor 1 x 1ml 1 x 10ml 10 x 10ml HHBS 1 x 9ml 1 x 100ml 0 x 0ml -
研究分野
画像
-
HEK cells transiently transfected with P2X receptor were seeded overnight at 40,000 cells/100 µL/well in a black wall/clear bottom 96-well plate. The cells were incubated with 100 µL of the MP sensor in a 5% CO2, 37 °C incubator for 60 minutes. ATP (50 µL/well) was added to achieve the final indicated concentrations. The fluorescence signal was measured with bottom read mode at Ex/Em = 620/650 nm (cutoff at 630 nm).
データシートおよび資料
-
SDS download
-
Datasheet download
参考文献 (1)
ab176765 は 1 報の論文で使用されています。
- Li Q et al. Thymol Disrupts Cell Homeostasis and Inhibits the Growth of Staphylococcus aureus. Contrast Media Mol Imaging 2022:8743096 (2022). PubMed: 36034206