JavaScript is disabled in your browser. Please enable JavaScript to view this website.
AB112122

Cell Viability Assay Kit (Fluorometric - Green)

Cell Viability Assay Kit (Fluorometric - Green)

Be the first to review this product! Submit a review

|

(2 Publications)

There are a variety of parameters that can be used to monitor cell viability.
1 Images
Functional Studies - Cell Viability Assay Kit (Fluorometric - Green) (AB112122)
  • FuncS

Supplier Data

Functional Studies - Cell Viability Assay Kit (Fluorometric - Green) (AB112122)

CHO-K1 cell number response was measured with ab112122. CHO-K1 cells at 0 to 5,000 cells/well/100 µL were seeded overnight in a black wall/clear bottom 96-well plate. The cells were incubated with 100 µL/well of Green dye-loading solution for 1 hour at 37 °C. The fluorescence intensity was measured at Ex/Em = 490/ 525 nm. The fluorescence intensity was linear (R2 = 1) to the cell number as indicated. The detection limit was 30 cells/well (n=6).

Key facts

検出方法

Fluorescent

サンプルタイプ

Suspension cells, Adherent cells

Quantitative
アッセイプラットフォーム

Microplate reader, Fluor. microscope, Flow cyt.

製品の詳細

There are a variety of parameters that can be used to monitor cell viability. The green fluorescent dye used in the kit is a hydrophobic compound. It easily permeates intact live cells and gets enhanced fluorescence upon entering into live cells. The hydrolysis of the non-fluorescent substrate by intracellular esterases generates a strongly green fluorescent hydrophilic product that is well-retained in the cell cytoplasm. The green fluorophore generated by the non-fluorescent substrate used in the kit has the spectral properties of fluorescein at Ex/Em = ~490 nm/520 nm. When well excited with the Argon Laser at 488 nm, the fluorophore emits intense green fluorescence at ~520 nm.

ab112122 provides all the essential components with an optimized cell-labeling protocol for fluorescence microplate assays. It can also be used with a fluorescence microscope equipped with a FITC filter set.

ab112122 provides an effective tool of labeling cells for fluorescence microplate and microscopic investigations of cellular functions. It is useful for a variety of studies, including cell adhesion, chemotaxis, multidrug resistance, cell viability, apoptosis and cytotoxicity. ab112122 is suitable for proliferating and non-proliferating cells.

Visit our FAQs page for tips and troubleshooting.

Review the cell health assay guide to learn about kits to perform a cell viability assaycytotoxicity assay and cell proliferation assay.

製品内容

{ "values": { "5x96Tests": { "sellingSize": "5 x 96 Tests", "publicAssetCode":"ab112122-5x96Tests", "assetComponentDetails": [ { "size":"5 x 1 Vial", "name":"CellGreen fluorescent dye", "number":"AB112122-CMP03", "productcode":"" }, { "size":"1 x 50 mL", "name":"Assay Buffer", "number":"AB112122-CMP01", "productcode":"" }, { "size":"1 x 200 µL", "name":"DMSO", "number":"AB112122-CMP02", "productcode":"" } ] } } }

出荷温度及び保存条件

出荷温度
Blue Ice
短期保存温度
-20°C
長期保存温度
-20°C
保管に関する情報
-20°C

製品プロトコール

ターゲットの情報

文献 (2)

Recent publications for all applications. Explore the full list and refine your search

Investigative radiology 58:388-395 PubMed36729074

2023

Multimodal In Vivo Tracking of Chimeric Antigen Receptor T Cells in Preclinical Glioblastoma Models.

Applications

Unspecified application

Species

Unspecified reactive species

Wei Emma Wu,Edwin Chang,Linchun Jin,Shiqin Liu,Ching-Hsin Huang,Rozy Kamal,Tie Liang,Nour Mary Aissaoui,Ashok J Theruvath,Laura Pisani,Michael Moseley,Tanya Stoyanova,Ramasamy Paulmurugan,Jianping Huang,Duane A Mitchell,Heike E Daldrup-Link

iScience 25:103770 PubMed35146387

2022

Establishment of a developmental toxicity assay based on human iPSC reporter to detect FGF signal disruption.

Applications

Unspecified application

Species

Unspecified reactive species

Seiya Kanno,Yusuke Okubo,Tatsuto Kageyama,Lei Yan,Satoshi Kitajima,Junji Fukuda
View all publications
websiteProtocolBooklet
en

Abcam product promise

当社は、高品質な試薬を通じてお客様の研究を力強くサポートすることをお約束いたします。ご使用いただく各段階で、常にお客様をサポートできる体制を整えております。万が一、製品が期待通りに機能しない場合は、「Abcam Product Promise」による当社保証制度に基づき、安心してご利用いただけます。
保証に関する詳細については利用規約をご確認ください。

Please note: All products are 'FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES'.

For licensing inquiries, please contact partnerships@abcam.com