アブカムでは最適な動作のために Google Chrome など最新ブラウザでの閲覧を推奨します。

Hello. We're improving abcam.com and we'd welcome your feedback.

Hello. We're improving abcam.com and we'd welcome your feedback.

Infomation icon

We haven't added this to the BETA yet

New BETA website

New BETA website

Hello. We're improving abcam.com and we'd welcome your feedback.

Take a look at our BETA site and see what we’ve done so far.

Switch on our new BETA site

Now available

Search and browse selected products

  • A selection of primary antibodies

Purchase these through your usual distributor

In the coming months

  • Additional product types
  • Supporting content
  • Sign in to your account
  • Purchase online
お問い合わせは電話 03-4571-1344 または メールでどうぞ

  • アカウント
  • ログアウト
ログイン または 新規登録

Welcome

ログイン または

すでにアカウントをお持ちですか?

新規登録
カート
クイック・オーダー
Abcam homepage

  • 研究用製品
    製品タイプ別
    一次抗体
    二次抗体
    イムノアッセイキット・試薬
    細胞・組織イメージング
    細胞・バイオケミカルアッセイ
    製品タイプ別
    タンパク質・ペプチド
    プロテオミクス
    アゴニスト・アクチベータ-・アンタゴニスト・インヒビター
    細胞株・ライゼート
    マルチプレックス・アッセイ
    研究分野別
    癌
    循環器系
    細胞生物学
    エピジェネティクス
    メタボリズム
    発生生物学
    研究分野別
    免疫学
    微生物学
    脳神経科学
    シグナル伝達
    ステムセル
  • カスタム製品 & パートナーシップ
    カスタム製品 & パートナーシップ

    診断や治療プログラムを加速するための、カスタム製品および商業化に向けたパートナーシップ

    カスタム製品

    私たちとパートナーになる

  • サポート
    サポートハブ

    研究のためのサポートとアドバイス

    サポートハブを表示

    プロトコール

    実験のステップごとの詳細

    プロトコールを表示

  • イベント
    • イベント・カレンダー
    • 癌
    • 循環器
    • エピジェネティクス&核内情報
    • 免疫学
    • ニューロサイエンス
    • ステムセル
    • 展示会
    • ウェビナー
    最新のイベント情報

    世界中でアブカムが主催する研究会やセミナーの日程、内容、演者など

    イベント・カレンダー

  • パスウェイ
    細胞シグナル伝達パスウェイ

    すべてのパスウェイを見る

    インタラクティブ・パスウェイを見る

  1. Link

    products/assay-kits/adp-assay-kit-colorimetricfluorometric-ab83359.pdf

  1. Send me a copy of this email
    I agree to the terms and conditions.
Signal Transduction Metabolism Energy Metabolism
Share by email

ADP Assay Kit (Colorimetric/Fluorometric) (ab83359)

  • Datasheet
  • SDS
  • Protocol Booklet
Submit a review Q&A (9)References (31)

Product price, shipping and contact information

Currently unavailable

申し訳ございませんが、現在表示できません。

こちらにお問い合わせいただくか、またはしばらく経ってから改めてお試しください

 

Loading size & price…

 

出荷および受注について

Shipping info

Promotion Information

Abpromise

保証された製品品質、優れたカスタマー・サポート。 詳細はこちら。

Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)
  • Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)
  • Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)
  • Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)

Key features and details

  • Assay type: Quantitative
  • Detection method: Colorimetric/Fluorometric
  • Platform: Microplate reader
  • Assay time: 1 hr
  • Sample type: Cell culture extracts, Cell culture media, Cell Lysate, Other biological fluids, Plasma, Serum, Tissue Extracts, Urine
  • Sensitivity: 1 µM

こちらの製品もご検討ください

ELISA
Product image
Human ATP Synthase ELISA Kit (Complex V) Profiling ELISA Kit (ab124539)
一次抗体
Product image
Anti-Glycogen synthase 1/GYS1 antibody [EP817Y] (ab40810)

関連製品

製品の概要

  • 製品名

    ADP Assay Kit (Colorimetric/Fluorometric)
  • 検出方法

    Colorimetric/Fluorometric
  • サンプルの種類

    Urine, Serum, Plasma, Cell culture extracts, Other biological fluids, Tissue Extracts, Cell Lysate, Cell culture media
  • アッセイタイプ

    Quantitative
  • 検出感度

    > 1 µM
  • 全工程の試験時間

    1h 00m
  • 種交差性

    交差種: Mammals, Other species
  • 製品の概要

    ADP Assay Kit (Colorimetric/Fluorometric) (ab83359) provides a convenient colorimetric and fluorometric method to measure ADP level.


    In the ADP assay, ADP is converted to ATP and pyruvate. The generated pyruvate can be quantified by colorimetric (ODmax = 570 nm) or fluorometric method (Ex/Em 535/587 nm).


    Conventionally, ADP levels are measured by luciferase/luciferin mediated assays after ADP is converted to ATP. However, the luciferase system is unstable and luminescence equipment is not generally available in most laboratories. In comparison, this assay is simple, sensitive, stable and high-throughput adaptable and can be used with conventional microplate readers.


    The ADP assay can detect as low as 1 μM ADP in biological samples.

  • 特記事項

    This product is manufactured by BioVision, an Abcam company and was previously called K355 ADP Colorimetric/Fluorometric Assay Kit. K355-100 is the same size as the 100 test size of ab83359.

    ADP is a product of ATP de-phosphorylation and it can be rephosphorylated to ATP. De-phosphorylation and re-phosphorylation occur via various phosphatases, phosphorylases and kinases. ADP is stored in platelets and can be released to interact with a variety of purinergic receptors. ADP levels regulate several enzymes involved in intermediary metabolism. ADP conversion to ATP primarily occurs within the mitochondrion and chloroplast although several such processes occur in the cytoplasm.

    The Safety Datasheet for this product has been updated for certain countries. Please check the current version in the SDS download section.

  • 試験プラットフォーム

    Microplate reader

製品の特性

  • 保存方法

    Store at -20°C. Please refer to protocols.
  • 内容 100 tests
    ADP Standard 1 vial
    Assay Buffer IV 1 x 25ml
    Converter Mix II 1 vial
    Development Enzyme Mix I 1 vial
    OxiRed Probe 1 x 200µl
  • 研究分野

    • Signal Transduction
    • Metabolism
    • Energy Metabolism
    • Kits/ Lysates/ Other
    • Kits
    • Cell Metabolism Kits
    • Other Metabolism Assay
    • Kits/ Lysates/ Other
    • Kits
    • Cell Metabolism Kits
    • Intermediary Metabolism Kits
    • Metabolism
    • Pathways and Processes
    • Metabolic signaling pathways
    • Energy transfer pathways
    • Energy Metabolism
  • 関連性

    ADP (Adenosine diphosphate) is a product of ATP dephosphorylation and it can be rephosphorylated to ATP. Dephosphorylation and rephosphorylation occur via various phosphatases, phosphorylases and kinases. ADP is stored in platelets and can be released to interact with a variety of purinergic receptors. ADP levels regulate several enzymes involved in intermediary metabolism. ADP conversion to ATP primarily occurs within the mitochondrion and chloroplast although several such processes occur in the cytoplasm.
  • 別名

    • Adenosine diphosphate

画像

  • Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)
    Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)

    ADP levels measured fluorometrically in cell culture supernatants (background signal subtracted, mean of duplicates; +/- SD).

  • Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)
    Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)

    ADP levels measured fluorometrically in cell lysates (background signal subtracted, mean of duplicates; +/- SD).

  • Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)
    Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)

    APD levels colorimetrically measured in biological fluids (rat plasma and serum, human saliva); background signal subtracted, mean of duplicates; +/- SD.

  • Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)
    Functional Studies - ADP Colorimetric/Fluorometric Assay Kit (ab83359)
    Colorimetric and Fluorometric examples of ADP Standard curve.

プロトコール

  • Protocol Booklet

Click here to view the general protocols

データシートおよび資料

  • SDS download

  • Datasheet download

    Download

参考文献 (31)

ab83359 を使用した論文を発表された方は、こちらまでお知らせください。データシートに掲載させていただきます。

ab83359 は 31 報の論文で使用されています。

  • Cisternas P  et al. Adiponectin and resistin modulate the progression of Alzheimer´s disease in a metabolic syndrome model. Front Endocrinol (Lausanne) 14:1237796 (2023). PubMed: 37732123
  • Gartz M  et al. ACTA1 H40Y mutant iPSC-derived skeletal myocytes display mitochondrial defects in an in vitro model of nemaline myopathy. Exp Cell Res 424:113507 (2023). PubMed: 36796746
  • Gherardelli C  et al. Lithium Enhances Hippocampal Glucose Metabolism in an In Vitro Mice Model of Alzheimer's Disease. Int J Mol Sci 23:N/A (2022). PubMed: 35955868
  • Rajagopalan KS  et al. Renal Ischemia Induces Epigenetic Changes in Apoptotic, Proteolytic, and Mitochondrial Genes in Swine Scattered Tubular-like Cells. Cells 11:N/A (2022). PubMed: 35681498
  • Markussen LK  et al. Lipolysis regulates major transcriptional programs in brown adipocytes. Nat Commun 13:3956 (2022). PubMed: 35803907
View all Publications for this product

レビューと Q&A

Show All レビュー Q&A
レビューを送る 質問を送る

1-9 of 9 Abreviews or Q&A

Question

Does 2.5% perchloric acid infer with the ADP assay kit (ab83359)? I would like to pre-treat my samples with 2.5% perchloric acid to remove protein prior to testing for ADP.

Read More

Abcam community

Verified customer

Asked on Oct 30 2012

Answer

Thank you for your inquiry.

I would recommend the spin column filters (ab93349) over the PCA treatment for deproteinization. Theoretically the PCA treatment should be fine, but since we have not tested the outcome of this assay with such treated samples, I would go with the spin filter to be sure of no adverse effects.
I hope this information helps. Please contact us with any other questions.

Read More

Abcam Scientific Support

Answered on Oct 30 2012

Question

I want to use this kit to study the conversion to ADP, so using Poly A and an enzyme and then detecting ADP rather than testing in cells or tissue. Do you think this will work?

Inquiry: I am looking for a rapid assay to detect CDP or IDP. Would your ADP Assay Kit ab83359 work in such an application? I assume that you are using a pyruvate kinase to convert ADP to ATP and pyruvate. If I created my own CDP or IDP standard, would the other kit components convert CDP to CTP + pyruvate or IDP to ITP + pyruvate?

Read More

Abcam community

Verified customer

Asked on Oct 11 2012

Answer

Thank you for contacting us.

Although the laboratory has not tested in the conditions you describe, using a reaction with an enzyme, they believe their is no compatibility issue and that it should work with some optimization. Same goes for the issue with CDP and IDP.

I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

Use our products? Submit an Abreview. Earn rewards!
https://www.abcam.com/abreviews

Read More

Abcam Scientific Support

Answered on Oct 11 2012

Question

deproteinization - necessary for these kits?

Read More

Abcam community

Verified customer

Asked on Jul 30 2012

Answer

Merci pour votre appel de vendredi.

Le laboratoire m'a pu confirmer que vous pouvez procéder sans lescolonnes:

Pour le kit ADP ab83359, les échantillons lysés dans le"ADP assay buffer" peuventêtre aliquotes et congelées à-80°C avant utilisation. Ces échantillons ne doivent pas être filtrés.

Pour le kit ATP ab83355 les échantillons lysés dans le "ATP assay buffer" doiventêtre congelés rapidement en utilisant de l'azote liquide ou de la glacesèche si vous devez conserver les échantillons.C'est recommandé pour des meilleurs résultats, dedéproteinerou filtrer les échantillons. Comme vous n'avez pas de filtres, le laboratoire m'a confirmé que vous pouvez les déproteiner par précipitation:

Deproteinizing Sample Preparation Protocol:
The following protocol can be proportionally scaled up for preparation of larger or smaller sample volumes.

Protein Precipitation:
For biological samples with protein concentration less than ˜20 mg/ml (tissue homogenate, cell lysate, urine, etc.) take 550 µl of sample, mix with 100 µl of ice cold Perchloric acid in 1.5 ml microfuge tubes, vortex briefly to mix well, place on ice for 5 minutes. Centrifuge at 13,000g for 2 minutes. Accurately transfer 480µl of the supernatant to a fresh tube.

For serum and other very high protein concentration samples, take 400 µl of sample and mix with 100 µl of ice cold Perchloric acid, place on ice for 5 minutes. Centrifuge at 13,000g for 2 minutes. Accurately transfer 380 µl of the supernatant to a fresh tube.

Depending on the nature of the analyte, the samples in Perchloric acid may be frozen at -70°C for up to a month for storage at this stage.
Sample Neutralization:
Add 20 µl of ice cold 6 N KOH and mix to neutralize the sample and precipitate excess Perchloric acid. There may be some gas (CO2) evolution so vent the sample tube. Place on ice for 5 minutes. Spin briefly (˜1-2 min). Samples are now deproteinized, neutralized, and Perchloric acid has been removed. The samples may now be used in a variety of assays directly.




Note 1: The deproteinized samples have been diluted to 80% of the original concentration (quantitation results should be divided by 0.8 to correct measured values back to original sample concentrations). For serum samples, the dilution is to 76% so divide assay values by 0.76 to correct values to original sample concentrations.

Note 2: For further analysis of samples, if assay buffer is 0.1M or stronger, samples up to 50 µl may be used directly in 100 µl assay reactions. If lower concentration buffers are used in the assay, correspondingly smaller sample volumes should be used to maintain assay reaction pH without significant changes.

J'espère que ces informations vous sont utiles. Veuillez ne pas hésiter à nous recontacter si vous avez des autres questions.

Read More

Abcam Scientific Support

Answered on Jul 30 2012

Question

what is assay buffer composition?

sample: purified protein in buffer (Tris, NaCl, TCEP (protease inhibitor) and 200 uM ATP)
the buffer by itself gives high background (OD570 = 0.5 or higher for 100 ul buffer)
What could be the problem?

Read More

Abcam community

Verified customer

Asked on Jul 10 2012

Answer

Unfortunately we do not give out our buffer components or compositions. Sorry about that.

Yes, it is very likely that the ATP in your buffer is giving the background. I would suggest doing a background control for each of the experimental samples, in order to account for this background in each of the readings.
Hope this information has been helpful for you. Please contact me again if you have any further questions.

Read More

Abcam Scientific Support

Answered on Jul 10 2012

Question

what is assay buffer composition?

sample: purified protein in buffer (Tris, NaCl, TCEP (protease inhibitor) and 200 uM ATP)
the buffer by itself gives high background (OD570 = 0.5 or higher for 100 ul buffer)
What could be the problem?

Read More

Abcam community

Verified customer

Asked on Jul 07 2012

Answer

Thank you for contacting us.

I apologize for the wait, but I have not yet heard back from the lab. I have sent another email to follow up with them.

Thank you for your patience and understanding.

Read More

Abcam Scientific Support

Answered on Jul 07 2012

Question

are sample lysates in Tris, EDTA compatible with kit?
can dilute samples in assay buffer or need to prepare samples again just in assay buffer?

Read More

Abcam community

Verified customer

Asked on May 25 2012

Answer

Thank you for contacting us.

I have checked with the lab and their advice is as follows:

For most efficient results, we always recommend that the samples be made in the assay buffer provided with the kit. In case of that not being possible due to sample limitations, one can dilute it in the assay buffer as a last resort. However, this might compromise the results to a certain extent.

I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

Use our products? Submit an Abreview. Earn rewards!
https://www.abcam.com/abreviews

Read More

Abcam Scientific Support

Answered on May 25 2012

Question

Does the assay buffer in both kits same?

Read More

Abcam community

Verified customer

Asked on May 22 2012

Answer

Thank you for contacting us.

I can confirm that the assay buffers in both the kits are different. These cannot be used interchangeably. If you are running out of buffers then let us know we can provide them separately.

I hope this information is helpful to you. Please do not hesitate to contact us if you need any more advice or information.

Use our products? Submit an Abreview. Earn rewards!
https://www.abcam.com/abreviews

Read More

Abcam Scientific Support

Answered on May 22 2012

Question

Thank you for this information. We have bought all three kits. I have some follow up questions.
Are the buffers from these three kits are exchangeable too?
Can the ADP converter enzyme from ADP/ATP ratio kits (ab 65313) be replaced by the ATP converter from the ATP kit (ab83355) or ADP converter from ADP kit (ab83359)?

Read More

Abcam community

Verified customer

Asked on Mar 14 2012

Answer

Thank you for your questions. My colleague is out of the office today but I would like to forward the response that we received from the lab:

Unfortunately, these three kits have different Assay buffers and converting enzyme mixes, so they can not be shared.

I hope this information will be useful, but please let me know if you have any further questions and I'll be happy to help.

Read More

Abcam Scientific Support

Answered on Mar 14 2012

Question

Has this kit been tested with bacteria or yeast?

Read More

Abcam community

Verified customer

Asked on Jul 15 2011

Answer

Thank you for your inquiry. This kit has not been tested with bacterial cells by the lab, however theoretically as long as the cells are prepared as indicated in the attached data sheet, it should work with such samples.  I hope this information helps. Please contact us with any other questions.

Read More

Abcam Scientific Support

Answered on Jul 15 2011

Please note: All products are "FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES"
For licensing inquiries, please contact partnerships@abcam.com

技術情報や製品情報をメールで受け取る 登録
製品・研究分野別
  • 癌
  • 循環器
  • 細胞生物学
  • 発生
  • エピジェネティクス&核内情報
  • 免疫学
  • メタボリズム
  • 感染症
  • ニューロサイエンス
  • シグナル伝達
  • ステムセル
製品・タイプ別
  • 一次抗体
  • 二次抗体
  • バイオケミカルズ
  • アイソタイプ・コントロール
  • マルチカラー・セレクター
  • キット
  • ローディング・コントロール
  • ライゼート
  • ペプチド
  • タンパク質
  • スライド
  • タグ抗体・細胞マーカー
  • その他試薬
サービス&サポート
  • サポート
  • よくあるお問い合わせ
  • プロトコール&トラブルシュート
  • ご購入に関して
  • お問い合わせフォーム
  • トレーニング
  • ターゲット別に見る
アブカムについて
  • 企業ウェブサイト
  • 投資家の皆様へ
  • 企業情報
  • 採用情報
  • アブカムについて
イベント
  • 展示会
  • カンファレンス
International websites
  • abcam.com
  • abcam.cn

Join with us

  • LinkedIn
  • facebook
  • Twitter
  • YouTube
  • Terms of sale
  • Website terms of use
  • Cookie policy
  • Privacy policy
  • Legal
© 1998-2025 Abcam plc. All rights reserved.