Mouse IL-4 抗体 Pair - BSA and Azide free (ab241928)
Key features and details
- Unconjugated capture and detector antibodies
- Adaptable to any antibody pair-based assay format
- Antibody concentration ~ 1 mg/ml
- BSA and azide free buffer - ready for conjugation
- Reacts with: Mouse
製品の概要
-
製品名
Mouse IL-4 Antibody Pair - BSA and Azide free
IL-4 キット 製品一覧 -
アッセイタイプ
ELISA set -
検出範囲
0.98 pg/ml - 125 pg/ml -
種交差性
交差種: Mouse -
製品の概要
The Antibody Pair can be used to quantify Mouse IL-4. BSA and Azide free antibody pairs include unconjugated capture and detector antibodies suitable for sandwich ELISAs. The antibodies are provided at an approximate concentration of 1 mg/ml as measured by the protein A280 method. The recommended antibody orientation is based on internal optimization for ELISA-based assays. Antibody orientation is assay dependent and needs to be optimized for each assay type. Both capture and detector antibodies are rabbit monoclonal antibodies delivering consistent, specific, and sensitive results.
For additional information on the performance of the antibody pair, see the equivalent SimpleStep ELISA® Kit (ab221833), which uses the same antibodies. However, due to differences in their formulation, this antibody pair cannot be used with the consumables provided with our SimpleStep ELISA Kits. Please note that the range provided for the pairs is only an estimation based on the performance of the related product using the same antibody pair. Performance of the antibody pair will depend on the specific characteristics of your assay. We guarantee the product works in sandwich ELISA, but we do not guarantee the sensitivity or dynamic range of the antibody pair in your assay.
-
アプリケーション
適用あり: Sandwich ELISAmore details -
試験プラットフォーム
Reagents
製品の特性
-
保存方法
Store at +4°C. Please refer to protocols. -
キャリア・フリー
はい -
内容 10 x 96 tests Mouse IL-4 Capture Antibody (unconjugated) 1 x 100µg Mouse IL-4 Detector Antibody (unconjugated) 1 x 100µg -
研究分野
-
機能
Participates in at least several B-cell activation processes as well as of other cell types. It is a costimulator of DNA-synthesis. It induces the expression of class II MHC molecules on resting B-cells. It enhances both secretion and cell surface expression of IgE and IgG1. It also regulates the expression of the low affinity Fc receptor for IgE (CD23) on both lymphocytes and monocytes. -
関連疾患
Genetic variations in IL4 may be a cause of susceptibility to ischemic stroke (ISCHSTR) [MIM:601367]; also known as cerebrovascular accident or cerebral infarction. A stroke is an acute neurologic event leading to death of neural tissue of the brain and resulting in loss of motor, sensory and/or cognitive function. Ischemic strokes, resulting from vascular occlusion, is considered to be a highly complex disease consisting of a group of heterogeneous disorders with multiple genetic and environmental risk factors. -
配列類似性
Belongs to the IL-4/IL-13 family. -
細胞内局在
Secreted. - Information by UniProt
-
別名
- B cell growth factor 1
- B cell IgG differentiation factor
- B Cell Stimulatory Factor 1
see all -
参照データベース
- Entrez Gene: 16189 Mouse
- SwissProt: P07750 Mouse
- Unigene: 276360 Mouse
アプリケーション
The Abpromise guarantee
Abpromise保証は、 次のテスト済みアプリケーションにおけるab241928の使用に適用されます
アプリケーションノートには、推奨の開始希釈率がありますが、適切な希釈率につきましてはご検討ください。
アプリケーション | Abreviews | 特記事項 |
---|---|---|
Sandwich ELISA |
Use at an assay dependent concentration.
|
特記事項 |
---|
Sandwich ELISA
Use at an assay dependent concentration. |
画像
-
Representative standard curve from corresponding SimpleStep ELISA® Kit (ab221833), which uses the same antibody pair. For additional information on the performance of pair and kit, refer to the corresponding kit datasheet. Due to differences in the formulation and format of the antibodies in this pair, they cannot be used as substitutes for the antibody components in our SimpleStep ELISA® Kits.
-
Representative standard curve from corresponding SimpleStep ELISA® Kit (ab221833), which uses the same antibody pair. For additional information on the performance of pair and kit, refer to the corresponding kit datasheet. Due to differences in the formulation and format of the antibodies in this pair, they cannot be used as substitutes for the antibody components in our SimpleStep ELISA® Kits.
-
Representative standard curve from corresponding SimpleStep ELISA® Kit (ab221833), which uses the same antibody pair. For additional information on the performance of pair and kit, refer to the corresponding kit datasheet. Due to differences in the formulation and format of the antibodies in this pair, they cannot be used as substitutes for the antibody components in our SimpleStep ELISA® Kits.
-
To learn more about the advantages of recombinant antibodies see here.
プロトコール
To our knowledge, customised protocols are not required for this product. Please try the standard protocols listed below and let us know how you get on.
データシートおよび資料
-
Datasheet download
参考文献 (0)
ab241928 は論文での使用が確認できていません。