製品の概要

  • 製品名

    Human Thrombomodulin ELISA Kit (CD141)
    Thrombomodulin キット 製品一覧
  • 検出方法

    Colorimetric
  • 再現性

    Intra-Assay(同時再現性)
    サンプル N 平均値 SD CV%
    Serum 6 3.9%
    Inter-Assay(日差再現性)
    サンプル N 平均値 SD CV%
    Serum 6 9.8%
  • サンプルの種類

    Cell culture supernatant, Serum, Plasma
  • アッセイタイプ

    Sandwich (quantitative)
  • 検出感度

    < 0.31 ng/ml
  • 検出範囲

    0.625 ng/ml - 20 ng/ml
  • 添加回収試験

    109 %

  • 全工程の試験時間

    1h 45m
  • ステップ

    Multiple steps standard assay
  • 種交差性

    交差種: Human
  • 製品の概要

    Abcam’s Thrombomodulin (CD141) Human in vitro ELISA (Enzyme-Linked Immunosorbent Assay) kit is designed for the quantitative measurement of Thrombomodulin (CD141) in serum, plasma, buffered solutions and supernatants.

    A monoclonal antibody specific for Thrombomodulin has been coated onto the wells of the microtiter strips provided. Samples, including standards of known Thrombomodulin concentrations, control specimens or unknowns are pipetted into these wells. During the first incubation, the standards or samples and a biotinylated monoclonal antibody specific for Thrombomodulin are simultaneously incubated. After washing, the enzyme Streptavidin-HRP, that binds the biotinylated antibody is added, incubated and washed. A TMB substrate solution is added which acts on the bound enzyme to induce a colored reaction product. The intensity of this colored product is directly proportional to the concentration of Thrombomodulin present in the samples.

    This kit will recognize both endogenous and recombinant Human Thrombomodulin.

  • アプリケーション

    適用あり: Sandwich ELISAmore details
  • 試験プラットフォーム

    Microplate

製品の特性

  • 保存方法

    Store at +4°C. Please refer to protocols.
  • 内容 ラベル 1 x 96 tests 2 x 96 tests
    10X Standard Diluent Buffer Black 1 x 25ml 1 x 25ml
    200X Wash Buffer White 1 x 10ml 2 x 10ml
    Biotinylated Antibody Diluent Red 1 x 7ml 1 x 13ml
    Biotinylated anti-Thrombomodulin Red 1 x 400µl 2 x 400µl
    Chromogen TMB Substrate Solution 1 x 11ml 1 x 24ml
    Control Silver 2 vials 4 vials
    HRP Diluent Red 1 x 23ml 1 x 23ml
    Stop Reagent Black 1 x 11ml 2 x 11ml
    Streptavidin-HRP 2 x 5µl 4 x 5µl
    Thrombomodulin Microplate (12 x 8 well strips) 1 unit 2 units
    Thrombomodulin Standard (lyophilized) Yellow 2 vials 4 vials
  • 研究分野

  • 機能

    Thrombomodulin is a specific endothelial cell receptor that forms a 1:1 stoichiometric complex with thrombin. This complex is responsible for the conversion of protein C to the activated protein C (protein Ca). Once evolved, protein Ca scissions the activated cofactors of the coagulation mechanism, factor Va and factor VIIIa, and thereby reduces the amount of thrombin generated.
  • 組織特異性

    Endothelial cells are unique in synthesizing thrombomodulin.
  • 関連疾患

    Defects in THBD are the cause of thrombophilia due to thrombomodulin defect (THR-THBD) [MIM:188040]. A hemostatic disorder characterized by a tendency to thrombosis.
    Defects in THBD are a cause of susceptibility to hemolytic uremic syndrome atypical type 6 (AHUS6) [MIM:612926]. An atypical form of hemolytic uremic syndrome. It is a complex genetic disease characterized by microangiopathic hemolytic anemia, thrombocytopenia, renal failure and absence of episodes of enterocolitis and diarrhea. In contrast to typical hemolytic uremic syndrome, atypical forms have a poorer prognosis, with higher death rates and frequent progression to end-stage renal disease. Note=Susceptibility to the development of atypical hemolytic uremic syndrome can be conferred by mutations in various components of or regulatory factors in the complement cascade system. Other genes may play a role in modifying the phenotype.
  • 配列類似性

    Contains 1 C-type lectin domain.
    Contains 6 EGF-like domains.
  • 翻訳後修飾

    N-glycosylated.
    The iron and 2-oxoglutarate dependent 3-hydroxylation of aspartate and asparagine is (R) stereospecific within EGF domains.
  • 細胞内局在

    Membrane.
  • Information by UniProt
  • 別名

    • AHUS 6
    • AHUS6
    • BDCA 3
    • BDCA3
    • CD 141
    • CD141
    • CD141 antigen
    • Fetomodulin
    • Thbd
    • THPH12
    • THRM
    • Thrombomodulin
    • TM
    • TRBM_HUMAN
    see all
  • 参照データベース

アプリケーション

Our Abpromise guarantee covers the use of ab46508 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

アプリケーション Abreviews 特記事項
Sandwich ELISA Use at an assay dependent concentration.

画像

  • Standard curve: mean of duplicates (+/- SD) with background reads subtracted
  • Thrombomodulin measured in biological fluids showing quantity (ng) per mL of tested sample. Samples were diluted 2-16 fold.

プロトコール

参考文献

This product has been referenced in:

  • Albert V  et al. Acute Traumatic Endotheliopathy in Isolated Severe Brain Injury and Its Impact on Clinical Outcome. Med Sci (Basel) 6:N/A (2018). Read more (PubMed: 29337920) »
  • Hasibuzzaman MM  et al. Association between arsenic exposure and soluble thrombomodulin: A cross sectional study in Bangladesh. PLoS One 12:e0175154 (2017). Read more (PubMed: 28399171) »
See all 6 Publications for this product

レビューと Q&A

1-5 of 5 Abreviews or Q&A

Simple & easy human thrombomodulin ELISA

Excellent Excellent 5/5 (Ease of Use)
Abreviews
Followed the data sheet in detail to measure thrombomodulin in human serum.
Well made product and easy to understand.
Would recommend.

Abcam user community

Verified customer

投稿 Jun 25 2014

Answer

Thank you very much for your understanding. The things are more clearer now. Lab has confirmed that the number K100624 (typos K10624) is indeed stands for standard vial.

They have also confirmed that the standard conc. should be between 11-16 ng/ml at 1ml reconstitution with diluent. The expected range value 11-16 ng/ml has been determined by 2 operators, 3 experiments, 6 replicates each.

So at this moment I am unsure about 7ng/ml reading of standard, which is about ˜50% lower than the expected. To understand this I have few questions to ask;

- Does all the 5 kits show conc. range of 7ng/ml?
- I have checked the order history of this kit and found that the same item was bought many times. Would you be so kind, letting me know the lot numbers affected by this problem. You have received >5 kits of batch number http://it.adminsite.com/admin/stock/stock_list.cfm?intAbID=46508&intStockID=1119463&fMain=1&fViewExpired=1&strViewOffice=%25 was this batch fine?
- Do you follow the protocol exactly as given on the datasheet? Have you changed any step?
- From you r experience do you think, only the standard is problematic? If you think other can also be, then which one you would choose?

I will look forward to hearing from you soon.

Read More

Answer

Thank you for your inquiry.


A panel of 40 human sera and 40 plasma samples were tested for CD141 in a recent batch. See results below

Sample Matrix Number of samples evaluated Range (ng/ml) Mean (ng/ml) Standard deviation (ng/ml)


Serum 40 1.9 – 11.2 7.1 2.5
Plasma 40 2.9 – 7.6 5.1 1.5


I hope this information helps. Please contact us with any other questions.

Read More

Question
Answer

Thank you for your telephone enquiry earlier this afternoon. I can confirm that the concentration of the streptavidin - HRP in the Human Thrombomodulin ELISA Kit is 1.0mg/ml. I hope this is helpful. If you have any further questions, please do not hesitate to contact us again.

Read More

Answer

Thanks for your enquiry.

My colleague is out of office and he has asked me to look after her customers during her absence.


The whole Thrombomodulin kit is stable if refrigerate (4°C) until at least for one year. However, we would suggest our customers to use it as soon as possible after purchase to make sure that our Abpromise guarantee applies (6 months after purchase).

The cytokine provided (Thrombomodulin lyophilized standard vial) is stable at 4°C several years. When the material is reconstituted, the stability is not guarantee even if frozen at -70°C. The vial should be resuspended immediately prior to use and then discard.

I hope this will be useful for you.

Read More