Anti-Plakophilin 3 抗体 [EPR5560] (ab109441)

製品の概要

  • 製品名Anti-Plakophilin 3 antibody [EPR5560]
    Plakophilin 3 一次抗体 製品一覧
  • 製品の詳細
    Rabbit monoclonal [EPR5560] to Plakophilin 3
  • アプリケーション適用あり: WB, IHC-Pmore details
    適用なし: Flow Cyt,ICC or IP
  • 種交差性
    交差種: Mouse, Rat, Human
  • 免疫原

    A synthetic peptide corresponding to residues in Human Plakophilin 3.

  • ポジティブ・コントロール
    • Caco2 and HACAT cell lysates; Human breast and kidney tissues.
  • 特記事項

    This product is a recombinant rabbit monoclonal antibody.

    Produced using Abcam’s RabMAb® technology. RabMAb® technology is covered by the following U.S. Patents, No. 5,675,063 and/or 7,429,487.

製品の特性

関連製品

アプリケーション

Our Abpromise guarantee covers the use of ab109441 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

アプリケーション Abreviews 特記事項
WB 1/10000 - 1/50000. Detects a band of approximately 87 kDa (predicted molecular weight: 87 kDa).
IHC-P 1/100 - 1/250. Perform heat mediated antigen retrieval via the pressure cooker method before commencing with IHC staining protocol.
  • 追加情報Is unsuitable for Flow Cyt,ICC or IP.
  • ターゲット情報

    Anti-Plakophilin 3 antibody [EPR5560] 画像

    • All lanes : Anti-Plakophilin 3 antibody [EPR5560] (ab109441) at 1/10000 dilution

      Lane 1 : Caco2 cell lysate
      Lane 2 : HACAT cell lysate

      Lysates/proteins at 10 µg per lane.


      Predicted band size : 87 kDa
      Observed band size : 87 kDa
    • ab109441 at 1/100 dilution staining Human paraffin-embedded breast tissue.
    • ab109441 at 1/100 dilution staining paraffin-embedded Human kidney tissue.
    • Equilibrium disassociation constant (KD)
      Learn more about KD

      Click here to learn more about KD

    Anti-Plakophilin 3 antibody [EPR5560] (ab109441) 使用論文

    ab109441 has not yet been referenced specifically in any publications.

    Product Wall

    Thank you for contacting us.

    We would not recommend to freeze the antibody again once it has been thawed and used on a few samples. These repeated freeze/thaw cycles could damage the antibody. Instead, we would suggest to prepare and freeze s...

    Read More

    Thank you for your enquiry.

    I can confirm that ab109441 has been tested successfully in IHC-P at a dilution of 1/100 - 1/250, as stated on the datasheet. Please note this is a guideline only, and may require some further optimization.
    ...

    Read More

    Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"