Mitochondria Isolation Kit for Tissue (with Dounce Homogenizer) (ab110169)


  • 製品名Mitochondria Isolation Kit for Tissue (with Dounce Homogenizer)
    Mitochondria Isolation キット 製品一覧
  • サンプルの種類
  • アッセイタイプQuantitative
  • 製品の概要

    ab110169 (MS851) contains sufficient reagents for up to 10 benchtop mitochondria isolations from hard or soft tissues. Isolated mitochondria can be analyzed by Western Blotting, Immunocapture, or Activity assay.

  • 特記事項

    Tested tissues: brain, liver and heart

  • アプリケーション適用あり: Functional Studiesmore details



    Our Abpromise guarantee covers the use of ab110169 in the following tested applications.

    The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

    アプリケーション Abreviews 特記事項
    Functional Studies Use at an assay dependent dilution. Mitochondria isolations from hard or soft tissues.

    Mitochondria Isolation Kit for Tissue (with Dounce Homogenizer) 画像

    • Rat liver mitochondria were isolated using Abcam's ab110169/MS851 Mitochondria Isolation Kit for Tissue (with Dounce Homogenizer). 2 µg (lane 1) and 10 µg (lane 2) of mitochondria were tested with Abcam's ab110413/MS604 (MitoProfile® Total OXPHOS Rodent WB Antibody Cocktail). Mitochondria are enriched and so Western blot band intensity of mitochondrial proteins is greater in these mitochondrial preparations when compared to homogenate at respective amounts, see lane 3 and 4


    Mitochondria Isolation Kit for Tissue (with Dounce Homogenizer) (ab110169) 使用論文

    This product has been referenced in:
    • Gu F  et al. Alterations in mitochondrial DNA copy number and the activities of electron transport chain complexes and pyruvate dehydrogenase in the frontal cortex from subjects with autism. Transl Psychiatry 3:e299 (2013). Read more (PubMed: 24002085) »
    • Lehmann HC  et al. Mitochondrial dysfunction in distal axons contributes to human immunodeficiency virus sensory neuropathy. Ann Neurol 69:100-10 (2011). Read more (PubMed: 21280080) »

    See all 5 Publications for this product

    Product Wall

    Please see below for further clarification regarding the following questions:

    Is it OK to extract mitos from frozen tissues?

    A: yes, you can extract mitos from frozen tissues but be aware that freezen/ thaw cycle would weaken the cell...

    Read More

    Yes, you can use frozen tissues as sample for all three kits. As a reminder, please follow each individual protocol included with each kit to prepare samples for that particular assay.

    Thank you for contacting us. Yes, we will guarantee ab110169 for use on any mammalian tissues. While it would not qualify for our Abtrial discount program, it will be covered under our Abpromise guarantee. If you have any trouble using this kit on huma...

    Read More

    Thank you for contacting us.

    Samples may be prepared as purified mitochondria, crudemitochondria. In most cases whole tissue or cell lysates aresuitable but these may require some sample optimization. Mitochondria samples can be prepared bys...

    Read More

    Thank you for your enquiry regarding ab110169: Mitochondria Isolation Kit for Tissue (with Dounce Homogenizer)

    It is not clear at which step the samples got bacterial contaminated.

    Unfortunately, it is difficult to remove bacteria c...

    Read More

    Gracias por contactarnos.

    Lamento mucho que el kit no haya llegado en perfecto estado a vuestro laboratorio.

    ¿Podrías por favor confirmarme el número de pedido del kit?

    También agradecerí...

    Read More

    Thank you fro your enquiry.

    I am sorry to confirm we would not recommend to use ab109718 Cell Fractionation Kit - HTor ab109719 Cell Fractionation Kit Standardfor isolation of mitochondria from tissue. They are designed for cell culture sing...

    Read More

    Please do not use a sonicatorin order to destroy your cells, as this will result in a complete lysis of the mitochondria as well. This means you will not be able to analyse the sample.

    However, we do have a kit in which we deliv...

    Read More

    Thank you for your inquiry.

    I am happy to confirm that our lab does not see any specific problems with the experimental set up and buffers your customer is planning to use.

    Cardiac tissue should be an excellent materials for isolati...

    Read More

    Thank you for contacting us.

    I have attached the SDS for each kit (Mitochondria Isolation Kit for Tissue) with and without Dounce homogenizer (ab110169 and ab110168), since they are slightly different.

    I hope this information is h...

    Read More