製品の概要

  • 製品名
    Human Neurotrophin 4 ELISA Kit
  • 検出方法
    Colorimetric
  • サンプルの種類
    Cell culture supernatant, Serum, Plasma
  • アッセイタイプ
    Sandwich (quantitative)
  • 検出感度
    < 2 pg/ml
  • 検出範囲
    1.4 pg/ml - 1000 pg/ml
  • 添加回収試験

    98 %

    特定サンプルでの回収試験
    サンプルの種類 平均 % 測定範囲
    Cell culture supernatant 101.5 87% - 110%
    Serum 98.98 85% - 108%
    Plasma 95.49 83% - 107%

  • ステップ
    Multiple steps standard assay
  • 種交差性
    交差種: Human
  • 製品の概要

    Abcam’s Neurotrophin 4 Human ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of Human Neurotrophin 4 in serum, plasma, and cell culture supernatants. (Human Neurotrophin 4 concentration is pretty low in normal serum/plasma, it may not be detected in this assay).

    This assay employs an antibody specific for Human Neurotrophin 4 coated on a 96-well plate. Standards and samples are pipetted into the wells and Neurotrophin 4 present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-Human Neurotrophin 4 antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of Neurotrophin 4 bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm.

  • 特記事項

    Optimization may be required with urine samples

  • アプリケーション
    適用あり: Sandwich ELISAmore details
  • 試験プラットフォーム
    Microplate

法規制情報

製品の特性

アプリケーション

Our Abpromise guarantee covers the use of ab100616 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

アプリケーション Abreviews 特記事項
Sandwich ELISA Use at an assay dependent concentration.

画像

  • Representative Standard Curve using ab100616

  • Representative Standard Curve using ab100616

プロトコール

参考文献

ab100616 has not yet been referenced specifically in any publications.

レビューと Q&A

There are currently no Customer reviews or Questions for ab100616.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"