製品の概要

  • 製品名
    Human MMP8 ELISA Kit
    MMP8 キット 製品一覧
  • 検出方法
    Colorimetric
  • サンプルの種類
    Cell culture supernatant, Serum, Plasma
  • アッセイタイプ
    Sandwich (quantitative)
  • 検出感度
    < 6 pg/ml
  • 検出範囲
    8.23 pg/ml - 6000 pg/ml
  • 添加回収試験

    95 %

    特定サンプルでの回収試験
    サンプルの種類 平均 % 測定範囲
    Cell culture supernatant 95.44 84% - 103%
    Serum 94.75 83% - 103%
    Plasma 97.13 85% - 104%

  • ステップ
    Multiple steps standard assay
  • 種交差性
    交差種: Human
  • 製品の概要

    Abcam’s MMP8 Human ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of Human MMP8 in serum, plasma, and cell culture supernatants. (Collect plasma using heparin as an anticoagulant. EDTA and Citrate are not recommended).

    This assay employs an antibody specific for Human MMP8 coated on a 96-well plate. Standards and samples are pipetted into the wells and MMP8 present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-Human MMP8 antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of MMP8 bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm.

  • 特記事項

    Optimisation may be required with urine samples.

  • アプリケーション
    適用あり: Sandwich ELISAmore details
  • 試験プラットフォーム
    Microplate

製品の特性

アプリケーション

Our Abpromise guarantee covers the use of ab100609 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

アプリケーション Abreviews 特記事項
Sandwich ELISA Use at an assay dependent concentration.

画像

  • Representative Standard Curve using ab100609.

プロトコール

参考文献

ab100609 has not yet been referenced specifically in any publications.

レビューと Q&A

Thank you for your patience.

The lab let me know the following:

ab100609 : Cross reactivity with mouse is unknown. If it helps, the capture antibody is monoclonal and the detection antibody is polyclonal.

ab100779 : Untes...

Read More

Thank you for contacting us.

I have contacted the lab regarding the cross-reactivity of the 2 kits and will let you know what I find out.

As for the testing discount program, we have the following general information:

For...

Read More