Human Follicle Stimulating Hormone ELISA Kit (ab108641)

製品の概要

  • 製品名Human Follicle Stimulating Hormone ELISA Kit
    Follicle Stimulating Hormone キット 製品一覧
  • 検出方法Colorimetric
  • テスト
    1 x 96 well plate
  • サンプルの種類
    Serum
  • アッセイタイプSandwich (quantitative)
  • 検出感度
    = 2.5 mIU/ml
  • 検出範囲
    2.5 mIU/ml - 200 mIU/ml
  • ステップMultiple steps standard assay
  • 種交差性
    交差種: Human
  • 製品の概要

    Abcam’s Follicle Stimulating Hormone in vitroELISA (Enzyme-Linked Immunosorbent Assay) kit is designed for the accurate quantitative measurement of Follicle Stimulating Hormone in Human serum.

    A 96-well plate has been precoated with anti-Follicle Stimulating Hormone antibodies. Samples and standards and are added to the wells, where Follicle Stimulating Hormone in the sample and standards binds to the precoated antibody. After incubation and washing, added Anti-Follicle Stimulating Hormone HRP conjugate binds to the antibody-Follicle Stimulating Hormone complex. After incubation, the wells are washed to remove unbound material and TMB substrate is then added which is catalyzed by HRP to produce blue coloration. The reaction is terminated by addition of Stop Solution which stops the color development and produces a color change from blue to yellow. The intensity of signal is directly proportional to the amount of Follicle Stimulating Hormone in the sample and the intensity is measured at 450 nm.

  • アプリケーション適用あり: Sandwich ELISAmore details
  • 試験プラットフォームMicroplate

製品の特性

アプリケーション

Our Abpromise guarantee covers the use of ab108641 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

アプリケーション Abreviews 特記事項
Sandwich ELISA Use at an assay dependent concentration.

Human Follicle Stimulating Hormone ELISA Kit 画像

  • Representative standard curve using ab108641

プロトコール

Human Follicle Stimulating Hormone ELISA Kit (ab108641) 使用論文

ab108641 has not yet been referenced specifically in any publications.

Product Wall

I have been informed by the lab that while these are specific to human FSH, the mouse serum may cause some background. We recommend optimizing the tests by running a serial dilution of the mouse serum to determine which dilution factor gives the least...

Read More

Thank you for contacting us and your interest in our products.

TheFollicle Stimulating Hormone Human ELISA Kit (ab108641) uses and anti-alpha-FSH monoclonal antibody for the capture and an anti-beta-FSH monoclonal antibody for the detection. ...

Read More

Thank you very much for your inquiry.

We do have no ELISA kit against LH, FSH or Progesterone which are tested against the rat proteins. We do have however such kits tested against the human protein, for which we have however not yet tested w...

Read More

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"