Human Angiogenesis 抗体 Array B (30 Targets)- Quantitative (ab197421)

製品の概要

  • 製品名
    Human Angiogenesis Antibody Array B (30 Targets)- Quantitative
    Angiogenesis Antibody Array antibody arrays 製品一覧
  • サンプルの種類
    Serum, Plasma, Other biological fluids, Cell Lysate, Cell culture media, Tissue Lysate
  • アッセイタイプ
    Quantitative
  • 全工程の試験時間
    6h 00m
  • 種交差性
    交差種: Human
  • 製品の概要

    ab197421 can be used for quantitative measurement of 30 Human Angiogenesis proteins. Suitable for serum, plasma, cell culture media, other body fluids, cell and tissue lysates.
    Targets: ANG-1, Angiostatin, CXCL16, EGF, FGF-4, Follistatin, G-CSF, GM-CSF, I-309, IL-1β, IL-4, IL-10, IL-12p40, IL-12p70, I-TAC, MCP-2, MCP-3, MCP-4, MMP-1, MMP-9, PECAM-1, TGFα, TGFβ3, Tie-1, Tie-2, uPAR, VEGF, VEGF R2, VEGF R3, VEGF-D. 

    Learn more about Quantitative antibody arrays

  • 特記事項

    Quantitative antibody arrays can be used to quantitate up to 40 cytokines with as little as 50 µL of sample. Arrays are available for 400 human and 200 mouse proteins. 

    Each glass slide is spotted with 16 identical antibody arrays and is provided with a 16 well gasket to allow separate samples to be applied to each array. Each antibody is spotted in quadruplicate in each array. For reproducible quantitation, eight of the arrays are used with a cocktail of protein standards to produce a standard curve. The same 8 standard curve arrays can be used across multiple slides, allowing measurement of 22 experimental samples with 2 slides, 36 with 3 slides etc. 

    For high through-put, 4 slides can be nested into a tray matching a standard microplate, allowing automated processing with a liquid handling workstation. 

    Array processing can be completed within one working day (see workflow diagram below) and arrays can be analyzed with a wide number of laser glass slide array / gene microarray scanners. If you don’t have a suitable scanner then we recommend our membrane antibody arrays, which can be analyzed with any WB chemiluminescent reader. 

    Learn more about quantitative antibody arrays 

    Learn more about membrane antibody arrays

法規制情報

製品の特性

画像

  • Assay summary for Abcam Human Angiogenesis Antibody Array B (30 Targets) - Quantitative (ab197421)

  • Array Map for Abcam Human Angiogenesis Antibody Array B (30 Targets) - Quantitative (ab197421)

  • Standard Curves obtained from Abcam Human Angiogenesis Antibody Array B (30 Targets) - Quantitative (ab197421)

プロトコール

参考文献

ab197421 has not yet been referenced specifically in any publications.

レビューと Q&A

There are currently no Questions for ab197421.
Please use the link above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"

登録