製品の概要

  • 製品名Anti-Cardiac Troponin I antibody
    Cardiac Troponin I 一次抗体 製品一覧
  • 製品の詳細
    Rabbit polyclonal to Cardiac Troponin I
  • 特異性This antibody detects endogenous levels of total cardiac Troponin I protein.
  • アプリケーション適用あり: ELISA, WB, IHC-Pmore details
  • 種交差性
    交差種: Human
    交差が予測される動物種: Mouse, Rat
  • 免疫原

    Synthesized non-phosphopeptide derived from human cardiac Troponin I around the phosphorylation site of serine 43.

  • ポジティブ・コントロール
    • Extracts from Jurkat cells.

製品の特性

関連製品

アプリケーション

Our Abpromise guarantee covers the use of ab59376 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

アプリケーション Abreviews 特記事項
ELISA 1/5000.
WB 1/500 - 1/1000. Detects a band of approximately 28 kDa (predicted molecular weight: 24 kDa).
IHC-P Use a concentration of 4 mg/ml. Perform heat mediated antigen retrieval before commencing with IHC staining protocol.

ターゲット情報

  • 機能Troponin I is the inhibitory subunit of troponin, the thin filament regulatory complex which confers calcium-sensitivity to striated muscle actomyosin ATPase activity.
  • 関連疾患Defects in TNNI3 are the cause of cardiomyopathy familial hypertrophic type 7 (CMH7) [MIM:613690]. Familial hypertrophic cardiomyopathy is a hereditary heart disorder characterized by ventricular hypertrophy, which is usually asymmetric and often involves the interventricular septum. The symptoms include dyspnea, syncope, collapse, palpitations, and chest pain. They can be readily provoked by exercise. The disorder has inter- and intrafamilial variability ranging from benign to malignant forms with high risk of cardiac failure and sudden cardiac death.
    Defects in TNNI3 are the cause of cardiomyopathy familial restrictive type 1 (RCM1) [MIM:115210]. RCM1 is an heart muscle disorder characterized by impaired filling of the ventricles with reduced diastolic volume, in the presence of normal or near normal wall thickness and systolic function.
    Defects in TNNI3 are the cause of cardiomyopathy dilated type 2A (CMD2A) [MIM:611880]. Dilated cardiomyopathy is a disorder characterized by ventricular dilation and impaired systolic function, resulting in congestive heart failure and arrhythmia. Patients are at risk of premature death.
    Defects in TNNI3 are the cause of cardiomyopathy dilated type 1FF (CMD1FF) [MIM:613286]. Dilated cardiomyopathy is a disorder characterized by ventricular dilation and impaired systolic function, resulting in congestive heart failure and arrhythmia. Patients are at risk of premature death.
  • 配列類似性Belongs to the troponin I family.
  • Information by UniProt
  • 参照データベース
  • 別名
    • cardiac muscle antibody
    • Cardiac troponin I antibody
    • cardiomyopathy, dilated 2A (autosomal recessive) antibody
    • Cardiomyopathy, familial hypertrophic, 7, included antibody
    • CMD1FF antibody
    • CMD2A antibody
    • CMH7 antibody
    • cTnI antibody
    • Familial hypertrophic cardiomyopathy 7 antibody
    • MGC116817 antibody
    • RCM1 antibody
    • Tn1 antibody
    • Tni antibody
    • TNN I3 antibody
    • TNNC 1 antibody
    • TNNC1 antibody
    • TNNI3 antibody
    • TNNI3_HUMAN antibody
    • Troponin I antibody
    • Troponin I cardiac antibody
    • Troponin I cardiac muscle antibody
    • Troponin I cardiac muscle isoform antibody
    • Troponin I type 3 cardiac antibody
    • troponin I, cardiac 3 antibody
    • TroponinI antibody
    • Ttroponin I type 3 (cardiac) antibody
    see all

Anti-Cardiac Troponin I antibody 画像

  • All lanes : Anti-Cardiac Troponin I antibody (ab59376) at 1/500 dilution

    Lane 1 : Extracts from Jurkat cells.
    Lane 2 : Extracts from Jurkat cells, plus peptide.


    Predicted band size : 24 kDa
    Observed band size : 28 kDa (why is the actual band size different from the predicted?)
  • Ab59376 staining human normal heart. Staining is localised to the cell membrane.
    Left panel: with primary antibody at 4 ug/ml. Right panel: isotype control.
    Sections were stained using an automated system DAKO Autostainer Plus , at room temperature. Sections were rehydrated and antigen retrieved with the Dako 3-in-1 antigen retrieval buffer EDTA pH 9.0 in a DAKO PT Link. Slides were peroxidase blocked in 3% H2O2 in methanol for 10 minutes. They were then blocked with Dako Protein block for 10 minutes (containing casein 0.25% in PBS) then incubated with primary antibody for 20 minutes and detected with Dako Envision Flex amplification kit for 30 minutes. Colorimetric detection was completed with diaminobenzidine for 5 minutes. Slides were counterstained with Haematoxylin and coverslipped under DePeX. Please note that for manual staining we recommend to optimize the primary antibody concentration and incubation time (overnight incubation), and amplification may be required.

Anti-Cardiac Troponin I antibody (ab59376) 使用論文

ab59376 has not yet been referenced specifically in any publications.

Product Wall

There are currently no Abreviews or Questions for ab59376.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"