製品の概要

  • 製品名Anti-ATP10D antibody
    ATP10D 一次抗体 製品一覧
  • 製品の詳細
    Rabbit polyclonal to ATP10D
  • アプリケーション適用あり: WB, ELISAmore details
  • 種交差性
    交差種: Human
    交差が予測される動物種: Rat, Rabbit, Horse, Guinea pig, Cow, Cat, Dog, Pig
  • 免疫原

    Synthetic peptide corresponding to a region within the C terminal amino acids 1151-1200 (NLLFTSAPPV IYGVLEKDVS AETLMQLPEL YRSGQKSEAY LPHTFWITLL) of Human ATP10D (NP_065186).

  • ポジティブ・コントロール
    • Fetal liver lysate

製品の特性

  • 製品の状態Liquid
  • 保存方法Shipped at 4°C. Upon delivery aliquot and store at -20°C. Avoid freeze / thaw cycles.
  • バッファーPreservative: None
    Constituents: 2% Sucrose, PBS
  • Concentration information loading...
  • 精製度Immunogen affinity purified
  • ポリ/モノポリクローナル
  • アイソタイプIgG
  • 研究分野

アプリケーション

Our Abpromise guarantee covers the use of ab81174 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

アプリケーション Abreviews 特記事項
WB Use a concentration of 1 µg/ml. Detects a band of approximately 65, >168 kDa (predicted molecular weight: 160 kDa). Good results were obtained when blocked with 5% non-fat dry milk in 0.05% PBS-T.
ELISA Use at an assay dependent concentration.

ELISA titre using peptide based assay 1/1562500.

ターゲット情報

  • 関連性The exact function of ATP10D remains unknown.
  • 細胞内局在Cell membrane; Multi-pass membrane protein. Endoplasmic reticulum membrane. Note: Exit from the endoplasmic reticulum requires the presence of TMEM30A, but not that of TMEM30B.
  • 参照データベース
  • 別名
    • ATP10D antibody
    • ATPase class V type 10D antibody
    • ATPVD antibody
    • KIAA1487 antibody
    • Probable phospholipid transporting ATPase VD antibody
    • Putative type IV aminophospholipid transporting ATPase antibody
    • Type IV aminophospholipid transporting ATPase antibody
    see all

Anti-ATP10D antibody 画像

  • Anti-ATP10D antibody (ab81174) at 1 µg/ml + fetal liver lysate at 10 µg

    Secondary
    HRP conjugated anti-Rabbit IgG at 1/50000 dilution

    Predicted band size : 160 kDa
    Observed band size : >168 kDa (why is the actual band size different from the predicted?)
    Additional bands at : 65 kDa. We are unsure as to the identity of these extra bands.

Anti-ATP10D antibody (ab81174) 使用論文

ab81174 has not yet been referenced specifically in any publications.

Product Wall

There are currently no Abreviews or Questions for ab81174.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"