Anti-COX IV 抗体 [20E8C12] (HRP) (ab197920)

製品の概要

  • 製品名
    Anti-COX IV antibody [20E8C12] (HRP)
    COX IV 一次抗体 製品一覧
  • 製品の詳細
    Mouse monoclonal [20E8C12] to COX IV (HRP)
  • 標識
    HRP
  • アプリケーション
    適用あり: WB, IHC-Pmore details
  • 種交差性
    交差種: Human
    交差が予測される動物種: Mouse, Rat, Cow, Drosophila melanogaster, Zebrafish
  • 免疫原

    Tissue, cells or virus corresponding to Cow COX IV. Purified mitochondrial Complex IV (Cow).

  • ポジティブ・コントロール
    • WB: Human heart mitochondria lysate. IHC-P: Normal human colon tissue.
  • 特記事項

     

     

製品の特性

アプリケーション

Our Abpromise guarantee covers the use of ab197920 in the following tested applications.

The application notes include recommended starting dilutions; optimal dilutions/concentrations should be determined by the end user.

アプリケーション Abreviews 特記事項
WB 1/5000. Detects a band of approximately 16 kDa (predicted molecular weight: 20 kDa).
IHC-P 1/100. Perform heat mediated antigen retrieval with citrate buffer pH 6 before commencing with IHC staining protocol.

ターゲット情報

  • 機能
    This protein is one of the nuclear-coded polypeptide chains of cytochrome c oxidase, the terminal oxidase in mitochondrial electron transport.
  • 組織特異性
    Ubiquitous.
  • 配列類似性
    Belongs to the cytochrome c oxidase IV family.
  • 細胞内局在
    Mitochondrion inner membrane.
  • Information by UniProt
  • 参照データベース
  • 別名
    • AL024441 antibody
    • COX 4 antibody
    • COX IV 1 antibody
    • COX IV antibody
    • COX IV-1 antibody
    • Cox4 antibody
    • COX41_HUMAN antibody
    • Cox4a antibody
    • COX4B antibody
    • COX4I1 antibody
    • COX4I2 antibody
    • COX4L2 antibody
    • COXIV antibody
    • Cytochrome c oxidase polypeptide IV antibody
    • Cytochrome c oxidase subunit 4 isoform 1 mitochondrial antibody
    • Cytochrome c oxidase subunit 4 isoform 1, mitochondrial antibody
    • Cytochrome C Oxidase subunit IV antibody
    • Cytochrome c oxidase subunit IV isoform 1 antibody
    • Cytochrome c oxidase subunit IV isoform 2 (lung) antibody
    • Cytochrome c oxydase subunit 4 antibody
    • dJ857M17.2 antibody
    • MGC105470 antibody
    • MGC72016 antibody
    see all

Anti-COX IV antibody [20E8C12] (HRP) 画像

  • IHC image of COX IV staining in a section of formalin-fixed paraffin-embedded normal human colon*, performed on a Leica BOND. The section was pre-treated using heat mediated antigen retrieval with sodium citrate buffer (pH6, epitope retrieval solution 1) for 20mins. The section was then incubated with ab197920, 1/100 dilution, for 15 mins at room temperature. DAB was used as the chromogen. The section was then counterstained with haematoxylin and mounted with DPX. The inset negative control image is taken from an identical assay without primary antibody.

    For other IHC staining systems (automated and non-automated) customers should optimize variable parameters such as antigen retrieval conditions, primary antibody concentration and antibody incubation times.

    *Tissue obtained from the Human Research Tissue Bank, supported by the NIHR Cambridge Biomedical Research Centre

  • Anti-COX IV antibody [20E8C12] (HRP) (ab197920) at 1/5000 dilution + Human heart tissue lysate - mitochondrial extract (ab110337) at 5 µg
    Developed using the ECL technique

    Performed under reducing conditions.

    Predicted band size : 20 kDa
    Observed band size : 16 kDa (why is the actual band size different from the predicted?)


    Exposure time : 10 seconds

    This blot was produced using a 4-12% Bis-tris gel under the MES buffer system. The gel was run at 200V for 35 minutes before being transferred onto a Nitrocellulose membrane at 30V for 70 minutes. The membrane was then blocked for an hour using 2% Bovine Serum Albumin before being incubated with ab197920 overnight at 4°C. Antibody binding was visualised using ECL development solution ab133406.

Anti-COX IV antibody [20E8C12] (HRP) (ab197920) 使用論文

ab197920 has not yet been referenced specifically in any publications.

Product Wall

There are currently no Abreviews or Questions for ab197920.
Please use the links above to contact us or submit feedback about this product.

Please note: All products are "FOR RESEARCH USE ONLY AND ARE NOT INTENDED FOR DIAGNOSTIC OR THERAPEUTIC USE"